An Integrated Sensing/Communication Architecture for Structural Health Monitoring

被引:7
作者
Merlino, Pierantonio [1 ]
Abramo, Antonio [1 ,2 ]
机构
[1] Univ Udine, Dipartimento Ingn Elettr Gestionale & Meccan, I-33100 Udine, Italy
[2] ETHLAB, Eurotech Grp, I-33020 Amaro, UD, Italy
关键词
Localization; near-field communication; sensor networks; structural health monitoring; SENSOR NETWORK; WIRELESS;
D O I
10.1109/JSEN.2009.2021792
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a novel sensor network architecture for structural health monitoring is presented. The system is based on the adoption of purposely developed contactless sensors that make use of near-field coupling to both sense the structure displacements and deploy a local communication network. The key features of the adopted technology are the low-realization costs and the lower power consumption that nodes feature as compared to traditional wireless communication. In addition, the use of a fully decentralized positioning algorithm, running on each node, is demonstrated as a viable mean for the local mapping of extended structures, thus crediting the architecture for the evaluation of structural in-plane deformations.
引用
收藏
页码:1397 / 1404
页数:8
相关论文
共 13 条
[1]   A mixed convex/nonconvex distributed localization approach for the deployment of indoor positioning services [J].
Abramo, Antonio ;
Blanchini, Franco ;
Geretti, Luca ;
Savorgnan, Carlo .
IEEE TRANSACTIONS ON MOBILE COMPUTING, 2008, 7 (11) :1325-1337
[2]  
ENX C, P RFIT 2005, P1
[3]  
Finkenzeller K., 2003, RFID HDB FUNDAMENTAL, V2nd ed.
[4]   A wireless sensor network node designed for exploring a structural health monitoring application [J].
Jian Wu ;
Shenfang Yuan ;
Xia Zhao ;
Yue Yin ;
Weisong Ye .
SMART MATERIALS AND STRUCTURES, 2007, 16 (05) :1898-1906
[5]   Two-tiered wireless sensor network architecture for structural health monitoring [J].
Kottapalli, VA ;
Kiremidjian, AS ;
Lynch, JP ;
Carryer, E ;
Kenny, TW ;
Law, KH ;
Lei, Y .
SMART STRUCTURES AND MATERIALS 2003: SMART SYSTEMS AND NONDESTRUCTIVE EVALUATION FOR CIVIL INFRASTRUCTURES, 2003, 5057 :8-19
[6]   Wireless sensors with dual-controller architecture for active diagnosis in structural health monitoring [J].
Liu, L. ;
Yuan, F. G. .
SMART MATERIALS & STRUCTURES, 2008, 17 (02)
[7]  
LYNCH J, 2007, SHOCK VIB DIG, V38, P91
[8]   Distributed computing and sensing for structural health monitoring systems [J].
Mitchell, K ;
Sana, S ;
Liu, PX ;
Cingirikonda, K ;
Rao, VS ;
Pottinger, HJ .
SMART STRUCTURES AND MATERIALS 2000: SMART ELECTRONICS AND MEMS, 2000, 3990 :156-166
[9]   A 195-Gb/s 1.2-W inductive inter-chip wireless superconnect with transmit power control scheme for 3-D-stacked system in a package [J].
Miura, N ;
Mizoguchi, D ;
Inoue, M ;
Sakurai, T ;
Kuroda, T .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2006, 41 (01) :23-34
[10]   Analysis and design of inductive coupling and transceiver circuit for inductive inter-chip wireless superconnect [J].
Miura, N ;
Mizoguchi, D ;
Sakurai, T ;
Kuroda, T .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2005, 40 (04) :829-837