Percutaneous imaging-guided core breast biopsy: 5 years' experience in a community hospital

被引:43
作者
Margolin, FR
Leung, JWT
Jacobs, RP
Denny, SR
机构
[1] Calif Pacific Med Ctr, Dept Radiol, Breast Hlth Ctr, San Francisco, CA 94118 USA
[2] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
D O I
10.2214/ajr.177.3.1770559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study reports the results of a percutaneous imaging-guided core breast biopsy program in a community hospital. MATERIALS AND METHODS. We reviewed the prospectively collected results of our imaging-guided core biopsy program during its first 5 years (1994-1998). A total of 1333 lesions (94% of which were Breast Imaging Reporting and Data System (BI-RADS) assessment category 4) were sampled in 1183 patients. Patients with BI-RADS assessment category 5 lesions were referred to surgeons. Stereotactic guidance was used for the core biopsy of 506 lesions, and sonography was used to guide the predominantly 16-gauge needle core biopsy of 827 solid masses. RESULTS. One hundred forty-seven cancers were diagnosed in 1333 biopsies, resulting in a positive yield of 11%. Of 1020 patients with benign, concordant core biopsy results, 981 (96%) had at least one follow-up imaging examination within 36 months of the biopsy. Nineteen (2%) of these 1020 patients had a suspicious change at follow-up; 18 of these patients underwent surgical excision with benign findings. No cancers were found at imaging follow-up or by tumor registry linkage. All malignant core biopsy results were confirmed as malignant at surgical excision (positive predictive value 100%). Twenty-two patients with atypical ductal hyperplasia at core biopsy had subsequent surgery, and 12 (55%) of them were found to have cancer at surgery. CONCLUSION. An imaging-guided core biopsy program, developed and implemented by a small group of radiologists in a community hospital, can achieve successful results and provide an important service to patients and a cost-effective alternative to surgical biopsy. Our program emphasized sonographic guidance and achieved high follow-up compliance.
引用
收藏
页码:559 / 564
页数:6
相关论文
共 25 条
  • [1] [Anonymous], BREAST IM REP DAT SY
  • [2] Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy
    Brenner, RJ
    Fajardo, L
    Fisher, PR
    Dershaw, DD
    Evans, WP
    Bassett, L
    Feig, S
    Mendelson, E
    Jackson, V
    Margolin, FR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) : 341 - 346
  • [3] Stereotactic core-needle breast biopsy: A multi-institutional prospective trial
    Brenner, RJ
    Bassett, LW
    Fajardo, LL
    Dershaw, DD
    Evans, WP
    Hunt, R
    Lee, C
    Tocino, I
    Fisher, P
    McCombs, M
    Jackson, VP
    Feig, SA
    Mendelson, EB
    Margolin, FR
    Bird, R
    Sayre, J
    [J]. RADIOLOGY, 2001, 218 (03) : 866 - 872
  • [4] Image-guided core-needle breast biopsy is an accurate technique to evaluate patients with nonpalpable imaging abnormalities
    Fuhrman, GM
    Cederbom, GJ
    Bolton, JS
    King, TA
    Duncan, JL
    Champaign, JL
    Smetherman, DH
    Farr, GH
    Kuske, RR
    McKinnon, WMP
    [J]. ANNALS OF SURGERY, 1998, 227 (06) : 932 - 937
  • [5] GERSON ES, 1999, AJR, V173, P845
  • [6] Compliance with recommended follow-up after percutaneous breast core biopsy
    Goodman, KA
    Birdwell, RL
    Ikeda, DM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (01) : 89 - 92
  • [7] Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up
    Jackman, RJ
    Nowels, KW
    Rodriguez-Soto, J
    Marzoni, FA
    Finkelstein, SI
    Shepard, MJ
    [J]. RADIOLOGY, 1999, 210 (03) : 799 - 805
  • [8] Follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: Frequency of mammographic change and false-negative rate
    Lee, CH
    Philpotts, LE
    Horvath, LJ
    Tocino, I
    [J]. RADIOLOGY, 1999, 212 (01) : 189 - 194
  • [9] Cost-effectiveness of stereotactic core needle biopsy: Analysis by means of mammographic findings
    Lee, CH
    Egglin, TK
    Philpotts, L
    Mainiero, MB
    Tocino, I
    [J]. RADIOLOGY, 1997, 202 (03) : 849 - 854
  • [10] LEUNG J, 2000, AJR S, V174, P4