Separation and determination of estrogen in the water environment by high performance liquid chromatography-fourier transform infrared spectroscopy

被引:11
作者
Zheng, Bei [1 ]
Li, Wentao [1 ]
Li, Hongyan [1 ]
Liu, Lin [2 ]
Lei, Pei [1 ]
Ge, Xiaopeng [3 ]
Yu, Zhiyong [1 ]
Zhou, Yiqi [3 ]
机构
[1] Chinese Acad Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[2] Northern Engn Design & Res Int Co, Shijiazhuang 050011, Peoples R China
[3] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
基金
中国国家自然科学基金;
关键词
GC-MS; FTIR; PRODUCTS; ACID; IDENTIFICATION; ISOMERS; SPECTRA;
D O I
10.1038/srep32264
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The components for connecting high-performance liquid chromatography (HPLC) with Fourier-transform infrared spectroscopy (FTIR) were investigated to determine estrogen in the water environment, including heating for atomization, solvent removal, sample deposition, drive control, spectrum collection, chip swap, cleaning and drying. Results showed that when the atomization temperature was increased to 388 K, the interference of mobile phase components (methanol, H2O, acetonitrile, and NaH2PO4) were completely removed in the IR measurement of estrogen, with 0.999 of similarity between IR spectra obtained after separation and corresponding to the standard IR spectra. In experiments with varying HPLC injection volumes, high similarity for IR spectra was obtained at 20 ul injection volume at 0.01 mg/L BPA while a useful IR spectrum for 10 ng/L BPA was obtained at 80 ul injection volume. In addition, estrogen concentrations in the natural water samples were calculated semi-quantitatively from the peak intensities of IR spectrum in the mid-infrared region.
引用
收藏
页数:9
相关论文
共 34 条
[11]   THE HYPHENATION OF CHROMATOGRAPHY AND FT-IR SPECTROMETRY [J].
GRIFFITHS, PR ;
PENTONEY, SL ;
GIORGETTI, A ;
SHAFER, KH .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :1349-&
[12]   Characterization of DOM as a function of MW by fluorescence EEM and HPLC-SEC using UVA, DOC, and fluorescence detection [J].
Her, N ;
Amy, G ;
McKnight, D ;
Sohn, J ;
Yoon, YM .
WATER RESEARCH, 2003, 37 (17) :4295-4303
[13]   Compositional Differences between Size Classes of Dissolved Organic Matter from Freshwater and Seawater Revealed by an HPLC-FTIR System [J].
Landry, Christian ;
Tremblay, Luc .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (03) :1700-1707
[14]   Variable selection in visible/near infrared spectra for linear and nonlinear calibrations: A case study to determine soluble solids content of beer [J].
Liu, Fei ;
Jiang, Yihong ;
He, Yong .
ANALYTICA CHIMICA ACTA, 2009, 635 (01) :45-52
[15]  
Liu Y., 2011, NAN CHANG U, P18
[16]   MEASUREMENT OF INFRARED EMISSION SPECTRA USING MULTIPLE-SCAN INTERFEROMETRY [J].
LOW, MJD ;
COLEMAN, I .
SPECTROCHIMICA ACTA, 1966, 22 (03) :369-&
[17]   Determination of Chlorinated Hydrocarbons in Water Using Highly Sensitive Mid-Infrared Sensor Technology [J].
Lu, Rui ;
Mizaikoff, Boris ;
Li, Wen-Wei ;
Qian, Chen ;
Katzir, Abraham ;
Raichlin, Yosef ;
Sheng, Guo-Ping ;
Yu, Han-Qing .
SCIENTIFIC REPORTS, 2013, 3
[18]   Kinetics and Mechanisms of Ciprofloxacin Oxidation on Hematite Surfaces [J].
Martin, Sebastien ;
Shchukarev, Andrey ;
Hanna, Khalil ;
Boily, Jean-Francois .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (20) :12197-12205
[19]   Application of HPLC-FTIR spectroscopy using thermospray interface for analysis of anionic surfactants [J].
Mottaleb, MA .
ANALYTICAL SCIENCES, 1999, 15 (11) :1137-1140
[20]   Application of an HPLC-FTIR modified thermospray interface for analysis of dye samples [J].
Mottaleb, MA ;
Littlejohn, D .
ANALYTICAL SCIENCES, 2001, 17 (03) :429-434