Tracking Cumulative Radiation Exposure in Orthopaedic Surgeons and Residents What Dose Are We Getting?

被引:47
作者
Gausden, Elizabeth B. [1 ]
Christ, Alexander B. [1 ]
Zeldin, Roseann [2 ]
Lane, Joseph M. [1 ]
McCarthy, Moira M. [1 ]
机构
[1] Hosp Special Surg, Dept Orthopaed, 535 E 70th St, New York, NY 10021 USA
[2] Hosp Special Surg, Dept Radiol, 535 E 70th St, New York, NY 10021 USA
关键词
OPERATING-ROOM PERSONNEL; C-ARM FLUOROSCOPY; IONIZING-RADIATION; FIXATION; HANDS; FRACTURES; TRAINEES; POSITION; HUMERUS; RISK;
D O I
10.2106/JBJS.16.01557
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study was to determine the amount of cumulative radiation exposure received by orthopaedic surgeons and residents in various subspecialties. We obtained dosimeter measures over 12 months on 24 residents and 16 attending surgeons. Methods: Monthly radiation exposure was measured over a 12-month period for 24 orthopaedic residents and 16 orthopaedic attending surgeons. The participants wore a Landauer Luxel dosimeter on the breast pocket of their lead apron. The dosimeters were exchanged every rotation (5 to 7 weeks) for the resident participants and every month for the attending surgeon participants. Radiation exposure was compared by orthopaedic subspecialty, level of training, and type of fluoroscopy used (regular C-arm compared with mini C-arm). Results: Orthopaedic residents participating in this study received monthly mean radiation exposures of 0.2 to 79 mrem/month, lower than the dose limits of 5,000 mrem/year recommended by the United States Nuclear Regulatory Commission (U.S. NRC). Senior residents rotating on trauma were exposed to the highest monthly radiation (79 mrem/month [range, 15 to 243 mrem/month]) compared with all other specialty rotations (p < 0.001). Similarly, attending orthopaedic surgeons who specialize in trauma or deformity surgery received the highest radiation exposure of their peers, and the mean exposure was 53 mrem/month (range, 0 to 355 mrem/month). Conclusions: Residents and attending surgeons performing trauma or deformity surgical procedures are exposed to significantly higher doses of radiation compared with all other subspecialties within orthopaedic surgery, but the doses are still within the recommended limits.
引用
收藏
页码:1324 / 1329
页数:6
相关论文
共 26 条
[1]  
Bagshaw Michael, 2008, Travel Med Infect Dis, V6, P125, DOI 10.1016/j.tmaid.2007.10.003
[2]  
BARRY TP, 1984, CLIN ORTHOP RELAT R, P160
[3]   Reduction of Radiation Exposure From C-Arm Fluoroscopy During Orthopaedic Trauma Operations With Introduction of Real-Time Dosimetry [J].
Baumgartner, Rita ;
Libuit, Kiley ;
Ren, Dennis ;
Bakr, Omar ;
Singh, Nathan ;
Kandemir, Utku ;
Marmor, Meir Tibi ;
Morshed, Saam .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (02) :E53-E58
[4]   Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience [J].
Botchu, Rajesh ;
Ravikumar, Kassetti .
INDIAN JOURNAL OF ORTHOPAEDICS, 2008, 42 (04) :471-473
[5]   Direct Beam Radiation Exposure to Surgeons During Pinning of Supracondylar Humerus Fractures: Does C-Arm Position and the Attending Surgeon Matter? [J].
Eismann, Emily A. ;
Wall, Eric J. ;
Thomas, Elizabeth C. ;
Little, Megan A. .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2014, 34 (02) :166-171
[6]   A Radiation Safety Training Program Results in Reduced Radiation Exposure for Orthopaedic Residents Using the Mini C-arm [J].
Gendelberg, David ;
Hennrikus, William ;
Slough, Jennifer ;
Armstrong, Douglas ;
King, Steven .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) :580-584
[7]   RADIATION EXPOSURE TO THE HANDS OF ORTHOPEDIC SURGEONS DURING PROCEDURES UNDER FLUOROSCOPIC X-RAY CONTROL [J].
GOLDSTONE, KE ;
WRIGHT, IH ;
COHEN, B .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) :899-901
[8]   The Effect of C-Arm Position on Radiation Exposure During Fixation of Pediatric Supracondylar Fractures of the Humerus [J].
Hsu, Raymond Y. ;
Lareau, Craig R. ;
Kim, Jeom Soon ;
Koruprolu, Sarath ;
Born, Christopher T. ;
Schiller, Jonathan R. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (15) :e129(1)
[9]   The compliance with and knowledge about radiation protection in operating room personnel: a cross-sectional study with a questionnaire [J].
Jentzsch, Thorsten ;
Pietsch, Christiane M. ;
Stigler, Brigitte ;
Ramseier, Leonhard E. ;
Seifert, Burkhardt ;
Werner, Clement M. L. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (09) :1233-1240
[10]   Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review [J].
Kesavachandran, Chandrasekharan Nair ;
Haamann, Frank ;
Nienhaus, Albert .
EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2012, 17