Determination of camostat and its metabolites in human plasma - Preservation of samples and quantification by a validated UHPLC-MS/MS method

被引:2
|
作者
Sorensen, Lambert K. [1 ]
Hasselstrom, Jorgen B. [1 ]
Gunst, Jesper D. [2 ]
Sogaard, Ole S. [2 ]
Kjolby, Mads [3 ,4 ,5 ]
机构
[1] Aarhus Univ, Dept Forens Med, Sect Forens Chem, Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Infect Dis, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Clin Pharmacol, Aarhus, Denmark
[4] Aarhus Univ, DANDRITE, Dept Biomed, Aarhus, Denmark
[5] Aarhus Univ Hosp, Steno Diabet Ctr Aarhus, Aarhus, Denmark
关键词
Camostat; FOY-305; GBPA; FOY-251; GBA; COVID-19; Esterase inhibitors; LC-MS/MS; PROTEASE INHIBITOR; BILIARY-EXCRETION; RAT; TMPRSS2;
D O I
10.1016/j.clinbiochem.2021.07.007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Camostat mesilate is a drug that is being repurposed for new applications such as that against COVID-19 and prostate cancer. This induces a need for the development of an analytical method for the quantification of camostat and its metabolites in plasma samples. Camostat is, however, very unstable in whole blood and plasma due to its two ester bonds. The molecule is readily hydrolysed by esterases to 4-(4-guanidinobenzoyloxy)phenylacetic acid (GBPA) and further to 4-guanidinobenzoic acid (GBA). For reliable quantification of camostat, a technique is required that can instantly inhibit esterases when blood samples are collected. Design and methods: An ultra-high-performance liquid chromatography-tandem mass spectrometry method (UHPLC-ESI-MS/MS) using stable isotopically labelled analogues as internal standards was developed and validated. Different esterase inhibitors were tested for their ability to stop the hydrolysis of camostat ester bonds. Results: Both diisopropylfluorophosphate (DFP) and paraoxon were discovered as efficient inhibitors of camostat metabolism at 10 mM concentrations. No significant changes in camostat and GBPA concentrations were observed in fluoride-citrate-DFP/paraoxon-preserved plasma after 24 h of storage at room temperature or 4 months of storage at-20 degrees C and-80 degrees C. The lower limits of quantification were 0.1 ng/mL for camostat and GBPA and 0.2 ng/mL for GBA. The mean true extraction recoveries were greater than 90%. The relative intralaboratory reproducibility standard deviations were at a maximum of 8% at concentrations of 1-800 ng/mL. The trueness expressed as the relative bias of the test results was within +/- 3% at concentrations of 1-800 ng/mL. Conclusions: A methodology was developed that preserves camostat and GBPA in plasma samples and provides accurate and sensitive quantification of camostat, GBPA and GBA by UHPLC-MS/MS.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 50 条
  • [41] UHPLC-MS/MS method for the quantitation of penicillin G and metabolites in citrus fruit using internal standards
    Canzani, Daniele
    Hsieh, Kevin
    Standland, Matthew
    Hammack, Walter
    Aldeek, Fadi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1044 : 87 - 94
  • [42] Targeted analysis of seven selected tryptophan-melatonin metabolites: Simultaneous quantification of plasma analytes using fast and sensitive UHPLC-MS/MS
    Kaleta, Michal
    Kolitha, Bhagya S.
    Novak, Ondrej
    Rad, Farshid Mashayekhy
    Bergquist, Jonas
    Ubhayasekera, S. J. Kumari A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2025, 1256
  • [43] Development and validation of a simple UHPLC-MS/MS method for the simultaneous determination of trimethylamine N-oxide, choline, and betaine in human plasma and urine
    Ocque, Andrew J.
    Stubbs, Jason R.
    Nolin, Thomas D.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 109 : 128 - 135
  • [44] Development and method validation for determination of acrylamide in food by modified QuEChERS and UHPLC-MS/MS analysis
    Cossu, Maurizio
    Sanna, Andrea
    Ledda, Giuseppe
    Chessa, Giannina
    Mangano, Giuseppe
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 135
  • [45] Development of a high-throughput UHPLC-MS/MS (SRM) method for the quantitation of endogenous glucagon from human plasma
    Howard, James W.
    Kay, Richard G.
    Tan, Tricia
    Minnion, James
    Ghatei, Mohammad
    Bloom, Steve
    Creaser, Colin S.
    BIOANALYSIS, 2014, 6 (24) : 3295 - 3309
  • [46] Ultra-sensitive quantification of the therapeutic cyclic peptide bremelanotide utilizing UHPLC-MS/MS for evaluation of its oral plasma pharmacokinetics
    Sauter, Max
    Uhl, Philipp
    Burhenne, Juergen
    Haefeli, Walter E.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 186
  • [47] LC-MS/MS method for the simultaneous quantification of artesunate and its metabolites dihydroartemisinin and dihydroartemisinin glucuronide in human plasma
    Geditz, Mirjam C. K.
    Heinkele, Georg
    Ahmed, Asma
    Kremsner, Peter G.
    Kerb, Reinhold
    Schwab, Matthias
    Hofmann, Ute
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (17) : 4299 - 4308
  • [48] LC-MS/MS method for the simultaneous quantification of artesunate and its metabolites dihydroartemisinin and dihydroartemisinin glucuronide in human plasma
    Mirjam C. K. Geditz
    Georg Heinkele
    Asma Ahmed
    Peter G. Kremsner
    Reinhold Kerb
    Matthias Schwab
    Ute Hofmann
    Analytical and Bioanalytical Chemistry, 2014, 406 : 4299 - 4308
  • [49] MULTIRESIDUE AND MULTICLASS DETERMINATION OF CURRENT-USE PESTICIDES (CUPs) IN WATER SAMPLES BY SPE AND UHPLC-MS/MS
    Avellar, Allisson A. da S.
    Prates, Gabriel A. B.
    Alves, Larissa da S.
    Prestes, Osmar D.
    Adaime, Martha B.
    Zanellaa, Renato
    QUIMICA NOVA, 2024, 47 (09):
  • [50] Magnetic restricted-access carbon nanotubes for SPME to determine cannabinoids in plasma samples by UHPLC-MS/MS
    Cruz, Jonas Carneiro
    Rosa, Mariana Azevedo
    Mores, Lucas
    Carasek, Eduardo
    de Souza Crippa, Jose Alexandre
    Figueiredo, Eduardo Costa
    Costa Queiroz, Maria Eugenia
    ANALYTICA CHIMICA ACTA, 2022, 1226