Determination of camostat and its metabolites in human plasma - Preservation of samples and quantification by a validated UHPLC-MS/MS method

被引:2
|
作者
Sorensen, Lambert K. [1 ]
Hasselstrom, Jorgen B. [1 ]
Gunst, Jesper D. [2 ]
Sogaard, Ole S. [2 ]
Kjolby, Mads [3 ,4 ,5 ]
机构
[1] Aarhus Univ, Dept Forens Med, Sect Forens Chem, Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Infect Dis, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Clin Pharmacol, Aarhus, Denmark
[4] Aarhus Univ, DANDRITE, Dept Biomed, Aarhus, Denmark
[5] Aarhus Univ Hosp, Steno Diabet Ctr Aarhus, Aarhus, Denmark
关键词
Camostat; FOY-305; GBPA; FOY-251; GBA; COVID-19; Esterase inhibitors; LC-MS/MS; PROTEASE INHIBITOR; BILIARY-EXCRETION; RAT; TMPRSS2;
D O I
10.1016/j.clinbiochem.2021.07.007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Camostat mesilate is a drug that is being repurposed for new applications such as that against COVID-19 and prostate cancer. This induces a need for the development of an analytical method for the quantification of camostat and its metabolites in plasma samples. Camostat is, however, very unstable in whole blood and plasma due to its two ester bonds. The molecule is readily hydrolysed by esterases to 4-(4-guanidinobenzoyloxy)phenylacetic acid (GBPA) and further to 4-guanidinobenzoic acid (GBA). For reliable quantification of camostat, a technique is required that can instantly inhibit esterases when blood samples are collected. Design and methods: An ultra-high-performance liquid chromatography-tandem mass spectrometry method (UHPLC-ESI-MS/MS) using stable isotopically labelled analogues as internal standards was developed and validated. Different esterase inhibitors were tested for their ability to stop the hydrolysis of camostat ester bonds. Results: Both diisopropylfluorophosphate (DFP) and paraoxon were discovered as efficient inhibitors of camostat metabolism at 10 mM concentrations. No significant changes in camostat and GBPA concentrations were observed in fluoride-citrate-DFP/paraoxon-preserved plasma after 24 h of storage at room temperature or 4 months of storage at-20 degrees C and-80 degrees C. The lower limits of quantification were 0.1 ng/mL for camostat and GBPA and 0.2 ng/mL for GBA. The mean true extraction recoveries were greater than 90%. The relative intralaboratory reproducibility standard deviations were at a maximum of 8% at concentrations of 1-800 ng/mL. The trueness expressed as the relative bias of the test results was within +/- 3% at concentrations of 1-800 ng/mL. Conclusions: A methodology was developed that preserves camostat and GBPA in plasma samples and provides accurate and sensitive quantification of camostat, GBPA and GBA by UHPLC-MS/MS.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 50 条
  • [21] An Innovative Approach to the Preparation of Plasma Samples for UHPLC-MS Analysis
    Kaiser, Michael
    Lacheta, Bartosch
    Passon, Maike
    Schieber, Andreas
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (23) : 6665 - 6671
  • [22] Multiclass method for pesticides quantification in honey by means of modified QuEChERS and UHPLC-MS/MS
    Souza Tette, Patricia Amaral
    da Silva Oliveira, Fabiano Aurelio
    Correa Pereira, Elba Nathalia
    Silva, Gilsara
    de Abreu Gloria, Maria Beatriz
    Fernandes, Christian
    FOOD CHEMISTRY, 2016, 211 : 130 - 139
  • [23] Determination of Anagrelide in Human Plasma by a Validated LC-MS/MS Method
    Svinarov, D.
    Kasabova, L.
    Kostova, K.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 722 - 722
  • [24] UHPLC-MS/MS quantification of buprenorphine, norbuprenorphine, methadone, and glucuronide conjugates in umbilical cord plasma
    Kyle, Amy Redmond
    Carmical, Jennifer
    Shah, Darshan
    Pryor, Jason
    Brown, Stacy
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (10) : 1567 - 1574
  • [25] Validated LC-MS/MS method for determination of Alverine and one of its hydroxy metabolites in human plasma along with its application to a bioequivalence study
    Gomes, Noel A.
    Laud, Avdhoot
    Pudage, Ashutosh
    Joshi, Santosh S.
    Vaidya, Vikas V.
    Tandel, Jayram A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 197 - 206
  • [26] Amanitin determination in bile samples by UHPLC-MS: LR-MS and HR-MS analytical performance
    Leite, Marta
    Freitas, Andreia
    Mitchell, Todd
    Barbosa, Jorge
    Ramos, Fernando
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 247
  • [27] Ferromagnetic particles as a rapid and robust sample preparation for the absolute quantification of seven eicosanoids in human plasma by UHPLC-MS/MS
    Suhr, Anna Catharina
    Bruegel, Mathias
    Maier, Barbara
    Holdt, Lesca Miriam
    Kleinhempel, Alisa
    Teupser, Daniel
    Grimm, Stefanie H.
    Vogeser, Michael
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 173 - 182
  • [28] Determination of mesalazine, a low bioavailability olsalazine metabolite in human plasma by UHPLC-MS/MS: Application to a pharmacokinetic study
    Banda, Jagadeesh
    Lakshmanan, Ramalingam
    Katepalli, Ramesh Babu
    Venati, Uday Kumar Reddy
    Koppula, Ramesh
    Prasad, V. V. S. Shiva
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1008 : 1 - 10
  • [29] UHPLC-MS/MS method for determination of atorvastatin calcium in human plasma: Application to a pharmacokinetic study based on healthy volunteers with specific genotype
    Xia, Binbin
    Li, Yali
    Zhang, Yatong
    Xue, Ming
    Li, Xiaorong
    Xu, Pingxiang
    Xia, Tao
    Chen, Shicai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 160 : 428 - 435
  • [30] A UHPLC-MS/MS method for the quantification of JIB-04 in rat plasma: Development, validation and application to pharmacokinetics study
    Wang, Yang
    Ma, Jing
    Martinez, Elisabeth D.
    Liang, Dong
    Xie, Huan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 191