Multi-range sensors for the measurement of liquid film thickness distributions based on electrical conductance

被引:27
|
作者
Tiwari, Rashmita [1 ]
Damsohn, Manuel [1 ]
Prasser, Horst-Michael [1 ]
Wymann, Daniel [2 ]
Gossweiler, Christoph [2 ]
机构
[1] ETH, Dept Mech & Proc Engn MAVT, Lab Nucl Energy Syst, CH-8092 Zurich, Switzerland
[2] Univ Appl Sci & Arts Northwestern Switzerland, Inst Thermal & Fluid Engn, CH-5210 Windisch, Switzerland
关键词
Gas-liquid flow; Film Flow; Annular flow; Liquid film thickness measurement; ENTRAINMENT RATE; ARRAY SENSOR; ANNULAR-FLOW;
D O I
10.1016/j.flowmeasinst.2014.09.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The paper presents an approach toward an enhancement of the measuring range of high-speed sensors for the measurement of liquid film thickness distributions based on electrical conductance. This type of sensors consists of electrodes mounted flush to the wall. The sampling of the current generated between a pair of neighboring electrode is used as a measure of the film thickness. Such sensors have a limited measuring range, which is proportional to the lateral distance between the electrodes. The range is therefore coupled to the spatial resolution. The proposed new design allows an extension of the film thickness range by combining electrode matrices of different resolution in one and the same sensor. In this way, a high spatial resolution is reached with a small thickness range, whereas a film thickness that exceeds the range of the high resolution measurement can still be acquired even though on the costs of a lower spatial resolution. A simultaneous signal acquisition with a sampling frequency of 32 kHz combines three measuring ranges for the characterization of a two-dimensional film thickness distribution: (I) thickness range 0-600 mu m, lateral resolution 2 x 2 mm(2), (2) thickness range 400-1300 mu m, lateral resolution 4 x 4 mm(2), and (3) thickness range 1000-3500 mu m, lateral resolution 12 x 12 mm(2). The functionality of this concept sensor is demonstrated by tests in a horizontal wavy stratified air-water flow at ambient conditions. Using flexible printed circuit board technology to manufacture the sensor makes it possible to place the sensor at the inner surface of a circular pipe. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:124 / 132
页数:9
相关论文
共 50 条
  • [31] Multi-Range Sequential Learning Based Dark Image Enhancement with Color Upgradation
    Das Mou, Trisha
    Alam, Saadia Binte
    Rahman, Md. Hasibur
    Srivastava, Gautam
    Hasan, Mahady
    Uddin, Mohammad Faisal
    APPLIED SCIENCES-BASEL, 2023, 13 (02):
  • [32] Measurement of liquid film thickness in micro square channel
    Han, Youngbae
    Shikazono, Naoki
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2009, 35 (10) : 896 - 903
  • [33] Measurement of liquid-film thickness by laser interferometry
    Nozhat, WM
    APPLIED OPTICS, 1997, 36 (30): : 7864 - 7869
  • [34] Measurement of liquid crystal film thickness using interferometry
    Kossivas, F.
    Kyprianou, A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (10)
  • [35] Automated optical liquid film thickness measurement method
    Shedd, TA
    Newell, TA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12): : 4205 - 4213
  • [36] An ultrasonic measurement method for full range of oil film thickness
    Zhang, Kai
    Dou, Pan
    Wu, Tonghai
    Feng, Kai
    Zhu, Youquan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2019, 233 (03) : 481 - 489
  • [37] Nanoscale film thickness measurement based on weak measurement
    Qin, Zirui
    Liu, Qinggang
    Yue, Chong
    Lang, Yaopu
    Zhou, Xinglin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (12):
  • [38] Conductance probe measurement method for falling film thickness around horizontal tube
    Hou, Hao
    Bi, Qin-Cheng
    Ma, Hong
    Shenyang Gongye Daxue Xuebao/Journal of Shenyang University of Technology, 2011, 33 (04): : 476 - 480
  • [39] Liquid Film Thickness Estimation using Electrical Capacitance Tomography
    Cui, Ziqiang
    Yang, Chengyi
    Sun, Benyuan
    Wang, Huaxiang
    MEASUREMENT SCIENCE REVIEW, 2014, 14 (01): : 8 - 15
  • [40] Multi-range Zero Dead Time Approach on FPGA Based Wide Range Neutron Monitoring System
    Zhu, Feng-Ming
    Chou, Hwai-Pwu
    Chen, Shin-Yu
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 122 - 125