Development of a B-factory monolithic active pixel detector-the continuous - Acquisition pixel prototypes

被引:16
作者
Barbero, A [1 ]
Varner, G
Bozek, A
Browder, T
Fang, F
Hazumi, A
Igarashi, A
Iwaida, S
Kennedy, J
Kent, N
Olsen, S
Palka, H
Rosen, A
Ruckman, L
Stanic, S
Trabelsi, K
Tsuboyama, T
Uchida, K
机构
[1] Univ Hawaii, Dept Phys & Astron, Honolulu, HI 96822 USA
[2] Polish Acad Sci, Inst Phys Nucl, PL-32342 Krakow, Poland
[3] KEK, High Energy Accelerator Res Organ, Tsukuba, Ibaraki 305080, Japan
[4] Univ Tsukuba, Tsukuba, Ibaraki 3058573, Japan
关键词
B factory; CMOS; MAPS; monolithic active pixel sensor; radiation hard; vertex detector;
D O I
10.1109/TNS.2005.852639
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Future vertex detection at an upgraded KEK-B factory, currently the highest luminosity collider in the world, will require a detector technology capable of withstanding the increased track density and the larger radiation exposure. Near the beam pipe, the current silicon strip detectors have projected occupancies in excess of 100%. Advances in monolithic active-pixel sensors (MAPS) look very promising to address this problem. These devices are also quite attractive due to the possibility of making them very thin-essential for improved tracking and vertexing in the low-momenta environment of a B-factory. In the context of the Belle vertex detector upgrade, the major obstacles to realizing such a device have been concerns about radiation hardness and readout speed. Two prototypes implemented in the TSMC 0.35 mu m process have been developed to address these issues. Denoted the continuous-acquisition pixel (CAP), the two variants of this architecture are distinguished in that CAP2 includes an eight-deep sampling pipeline within each 22.5 mu m(2) pixel. Experience with this deep submicron process indicates tolerable threshold voltage shifts for ionizing radiation in excess of 20 Mrad. In order to maintain low occupancy and insensitivity to radiation-induced increased leakage current,, correlated double sampling with a 10 mu s frame period is needed. Device description, hit resolution, and irradiation results are presented.
引用
收藏
页码:1187 / 1191
页数:5
相关论文
共 9 条
[1]   Design and test of the CMS pixel readout chip [J].
Barbero, M ;
Bertl, W ;
Dietrich, G ;
Dorokhov, A ;
Erdmann, W ;
Gabathuler, K ;
Heising, S ;
Hörmann, C ;
Horisberger, R ;
Kästli, HC ;
Kotlinski, D ;
Meier, B ;
Weber, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 517 (1-3) :349-359
[2]   Particle tracking using CMOS monolithic active pixel sensor [J].
Claus, G ;
Colledani, C ;
Dulinski, W ;
Husson, D ;
Turchetta, R ;
Riester, JL ;
Deptuch, G ;
Orazi, G ;
Winter, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (01) :120-124
[3]   A CCD-BASED VERTEX DETECTOR FOR SLD [J].
DAMERELL, CJS ;
ENGLISH, RL ;
GILLMAN, AR ;
LINTERN, AL ;
PHILLIPS, D ;
SU, D ;
WICKENS, FJ ;
AGNEW, G ;
CLARKE, P ;
HEDGES, S ;
MCKEMEY, A ;
WATTS, SJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :236-239
[4]   Design and characterization of ionizing radiation-tolerant CMOS APS image sensors up to 30 Mrd (Si) total dose [J].
Eid, ES ;
Chan, TY ;
Fossum, ER ;
Tsai, RH ;
Spagnuolo, R ;
Deily, J ;
Byers, WB ;
Peden, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) :1796-1806
[5]  
KUROKAWA S, 2001, NUCL INSTRUM METH A, V499, P1
[6]   Charged particle detection using a CMOS active pixel sensor [J].
Matis, HS ;
Bieser, F ;
Kleinfelder, S ;
Rai, G ;
Retiere, F ;
Ritter, HG ;
Singh, K ;
Wurzel, SE ;
Wieman, H ;
Yamamoto, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) :1020-1025
[7]   A monolithic active pixel sensor for charged particle tracking and imaging using standard VLSI CMOS technology [J].
Turchetta, R ;
Berst, JD ;
Casadei, B ;
Claus, G ;
Colledani, C ;
Dulinski, W ;
Hu, Y ;
Husson, D ;
Le Normand, JP ;
Riester, JL ;
Deptuch, G ;
Goerlach, U ;
Higueret, S ;
Winter, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (03) :677-689
[8]   Belle silicon vertex detectors [J].
Ushiroda, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2) :6-10
[9]  
CERNAC9505