Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques

被引:7
|
作者
Sluiter, Nina Roelie [1 ]
Vlek, Stijn Lucas [1 ]
Wijsmuller, Arthur Randolph [1 ]
Brandsma, Henk Thijs [1 ]
de Vet, Henrica Cornelia Wilhelmina [2 ]
van Grieken, Nicole Cornelia Theodora [3 ]
Kazemier, Geert [1 ]
Tuynman, Jurriaan Benjamin [1 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam UMC, Canc Ctr Amsterdam, Dept Surg, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Amsterdam UMC, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Amsterdam UMC, Dept Pathol, Amsterdam, Netherlands
关键词
HYPERTHERMIC INTRAPERITONEAL CHEMOTHERAPY; CYTOREDUCTIVE SURGERY; INDOCYANINE GREEN; SYSTEMIC CHEMOTHERAPY; CANCER METASTASES; PATIENT SELECTION; CARCINOMATOSIS; LAPAROSCOPY; HIPEC; DIAGNOSIS;
D O I
10.1245/s10434-018-7005-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundColorectal peritoneal metastases (PM) are often diagnosed in an advanced disease stage. Cytoreduction and hyperthermic intraperitoneal chemotherapy (HIPEC) improve survival of patients with colorectal PM, although most benefit is seen in patients with limited peritoneal disease. Advanced imaging techniques might improve the detection of PM, potentially leading to earlier diagnosis and improved cytoreduction. This prospective clinical trial compared three advanced techniques with conventional white-light imaging for the detection of colorectal PM: narrow-band imaging (NBI), near-infrared indocyanine green fluorescent imaging (NIR-ICG), and spray-dye chromoendoscopy (SDCE). MethodsPatients with colorectal PM were prospectively included. Prior to cytoreduction and HIPEC, all abdominal regions were inspected with white-light imaging, NBI, NIR-ICG, and SDCE during exploratory laparoscopy. Primary endpoints were sensitivity and specificity for the detection of PM, using pathological examination of biopsied lesions as the reference standard. The safety of all techniques was assessed.ResultsBetween May 2016 and March 2018, four different techniques were analyzed in 28 patients, resulting in 169 biopsies. Sensitivity for the detection of PM significantly increased from 80.0% with white light to 96.0% with NBI (p=0.008), without loss of specificity (74.8% vs. 73.1%, respectively, p=0.804). The use of NIR-ICG and SDCE was discontinued after 10 patients had undergone treatment because the lesions were not fluorescent using NIR-ICG, and because SDCE did not visualize the whole peritoneum. No adverse events relating to the imaging techniques occurred.ConclusionNBI substantially increased the detection of PM. This method is safe and could improve the detection of metastatic lesions and help optimize cytoreduction in patients with colorectal PM.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 50 条
  • [1] Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques
    Nina Roelie Sluiter
    Stijn Lucas Vlek
    Arthur Randolph Wijsmuller
    Henk Thijs Brandsma
    Henrica Cornelia Wilhelmina de Vet
    Nicole Cornelia Theodora van Grieken
    Geert Kazemier
    Jurriaan Benjamin Tuynman
    Annals of Surgical Oncology, 2019, 26 : 156 - 164
  • [2] Narrow-band imaging and detection of colorectal adenoma
    Lok, K-H
    Szeto, M-L
    GUT, 2008, 57 (09) : 1331 - 1331
  • [3] Updates in narrow-band imaging for colorectal polyps: Narrow-band imaging generations, detection, diagnosis, and artificial intelligence
    Teramoto, Akira
    Hamada, Seiji
    Ogino, Banri
    Yasuda, Ichiro
    Sano, Yasushi
    DIGESTIVE ENDOSCOPY, 2023, 35 (04) : 453 - 470
  • [4] Narrow-Band Imaging Improves the Detection of Polyps in Patients with Hyperplastic Polyposis Syndrome: A Prospective Randomized Study Comparing Narrow-Band Imaging vs High-Resolution White Light Imaging
    Boparai, Karam S.
    Van den Broek, Frank J.
    Van Eeden, Susanne
    Fockens, Paul
    Dekker, Evelien
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB287 - AB287
  • [5] Narrow-band imaging in the diagnosis of colorectal mucosal lesions: A pilot study
    Machida, H
    Sano, Y
    Hamamoto, Y
    Muto, M
    Kozu, T
    Tajiri, H
    Yoshida, S
    ENDOSCOPY, 2004, 36 (12) : 1094 - 1098
  • [6] Narrow-band imaging and white-light endoscopy for detection of colorectal polyps: a randomized study
    Kakol, Dariusz
    Fraczek, Mariusz
    Banaszkiewicz, Aleksandra
    Pertkiewicz, Jan
    POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ-POLISH ARCHIVES OF INTERNAL MEDICINE, 2013, 123 (10): : 519 - 525
  • [7] Linked color imaging versus narrow-band imaging for colorectal polyp detection: a prospective randomized tandem colonoscopy study
    Leung, Wai K.
    Guo, Chuan-guo
    Ko, Michael K. L.
    To, Elvis W. P.
    Mak, Lung Yi
    Tong, Teresa S. M.
    Chen, Li-Jia
    But, David Y. K.
    Wong, Siu Yin
    Liu, Kevin S. H.
    Tsui, Vivian
    Lam, Frank Y. F.
    Lui, Thomas K. L.
    Cheung, Ka Shing
    Lo, Siu Hung
    Hung, Ivan F. N.
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (01) : 104 - +
  • [8] A prospective randomised study on narrow-band imaging versus conventional colonoscopy for adenoma detection:: does narrow-band imaging induce a learning effect?
    Adler, A.
    Pohl, H.
    Papanikolaou, I. S.
    Abou-Rebyeh, H.
    Schachschal, G.
    Veltzke-Schlieker, W.
    Khalifa, A. C.
    Setka, E.
    Koch, M.
    Wiedenmann, B.
    Roesch, T.
    GUT, 2008, 57 (01) : 59 - 64
  • [9] Use of narrow-band imaging in detection of nasopharyngeal carcinoma
    Thong, J. F.
    Loke, D.
    Sivasankarannair, R. Karumathil
    Mok, P.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2013, 127 (02): : 163 - 169
  • [10] Detection of bladder cancer with narrow-band imaging system
    Katsunori, Tatsugarni
    Toshiyuki, Kamoto
    Hiroyuki, Nishiyama
    Satoru, Ishikawa
    Nobuo, Shinohara
    Seiji, Naito
    JOURNAL OF ENDOUROLOGY, 2007, 21 : A164 - A164