In this work, the use of R1234yf as a drop-in replacement for R134a in an air to water refrigeration system used to produce cool water at 7 degrees C is studied. This equipment was constructed in our laboratory with a minichannel heat exchanger working as condenser and a plate heat exchanger working as evaporator resulting in a 2.5 kW water chiller, which initially was working with R134a as refrigerant. A brief description of the refrigeration system and the installation used to test its behaviour as well as the uncertainty analysis is presented. Then, the test matrix defined in order to evaluate the effect of the different variables of interest on the performance of the refrigeration cycle is also presented. Air inlet temperature in the condenser was varied in order to analyse the influence of a variation in the ambient temperature. Other variables were varied in order to analyse the influence of different operating conditions as a variation in the compressor frequency or in the condenser fan velocity (by varying air inlet velocity). Finally, the subcooling degree was varied in order to compare a system with refrigerant receiver (no subcooling) and a system without refrigerant receiver and different refrigerant charge (different subcooling). According to the results obtained, R1234yf performs worse than R134a, presenting lower cooling capacity and higher compressor consumption in all tests, with a global efficiency around 25% lower. This can be explained by its lower isentropic and volumetric efficiency, which could be related to the type of lubricant used. (C) 2018 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [1] Comparison of transient response of an evaporator model for water refrigeration system working with R1234yf as a drop-in replacement for R134a
    Garcia, Juan
    Ali, Thiago
    Duarte, Willian Moreira
    Khosravi, Ali
    Machado, Luiz
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 91 : 211 - 222
  • [2] Performance of Automotive Air Conditioning System with R134a and R1234yf
    Kuwar, Yogendra Vasantrao
    Narasimham, G. S. V. L.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2020, 28 (02)
  • [3] R1234yf vs R134a in automotive air conditioning system: A comparison of the performance
    Sharif, M. Z.
    Azmi, W. H.
    Zawawi, N. N. M.
    Mamat, R.
    Hamisa, A. H.
    SYMPOSIUM ON ENERGY SYSTEMS 2019 (SES 2019), 2020, 863
  • [4] Experimental Performance Analysis of R1234yf in an Air-Conditioning System as Substitute of R134a
    Medany, M. M.
    El Morsi, M.
    El-Sayed, A. R.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (04)
  • [5] Experimental Analysis of the Vapour Compression Refrigeration System with Microchannel Condenser using R134a and R1234yf Refrigerant
    Prakash, K. B.
    Subramanian, C.
    Chandrasekaran, M.
    Kalidasan, B.
    Amarkarthik, A.
    Manojkumar, P.
    Saravanakumar, S.
    JOURNAL OF ENGINEERING RESEARCH, 2021, 9
  • [6] Experimental study of R1234yf as a drop-in replacement for R134a in an oil-free refrigeration system
    Li, Zhaohua
    Liang, Kun
    Jiang, Hanying
    APPLIED THERMAL ENGINEERING, 2019, 153 : 646 - 654
  • [7] Thermodynamic performance comparison and experimental study of mixed refrigerant R134a/R1234yf (R513A) and R134a
    Yang, Meng
    Zhang, Hua
    Qin, Yanbin
    Meng, Zhaofeng
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (03): : 1182 - 1189
  • [8] Experimental Evaluation of an Automotive Heat Pump System with R1234yf as an Alternative to R134a
    Direk, Mehmet
    Yuksel, Fikret
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (02) : 719 - 728
  • [9] Experimental Evaluation of an Automotive Heat Pump System with R1234yf as an Alternative to R134a
    Mehmet Direk
    Fikret Yüksel
    Arabian Journal for Science and Engineering, 2020, 45 : 719 - 728
  • [10] Theoretical analysis of R1234yf and R1234yf/R125 mixture as replacement of R134a in vapor compression system
    Lin, Yongmei
    Meng, Zhaofeng
    Huo, Ziheng
    Ding, Chuangchuang
    Wang, Song
    Wang, Longji
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 490 - 496