摘要
Potential systemic markers of implant wear include products of the wear process (particles and ions) and mediators of the inflammatory reaction that can be induced by wear. Ions from polymers used in arthroplasty are not specific, but high metal ion levels may help identify patients with unexpectedly high wear of metal-on-metal implants. The kinetics of ion production, transport, and excretion are complex, however, so it is currently difficult to interpret the significance of mild elevations in metal ions. Indices of bone turnover (eg, collagen fragments) and mediators involved in the inflammatory reaction to particles eg, osteoprotegerin, RANKL, interleukins) may be associated with osteolysis, but systemic disorders (eg, osteoarthritis) and the use of medications that influence bone remodeling limit the predictive value of these analytes with respect to the consequences of implant wear. Using genomic and proteomic methods to measure multiple analytes offers promise, but the challenge is to identify markers specifically associated with wear that are not elevated by other conditions that often coexist in this patient population.
引用
收藏
页码:S68 / S71
页数:4
相关论文
共 22 条
[1]   Collagen crosslinked N-telopeptides as markers for evaluating particulate osteolysis: A preliminary study [J].
Antoniou, J ;
Huk, O ;
Zukor, D ;
Eyre, D ;
Alini, M .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (01) :64-67
[2]   Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Grübl, A ;
Jankovsky, R ;
Meisinger, V ;
Lehr, S ;
Gottsauner-Wolf, F .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :66-70
[3]  
Gonzalez O, 1996, J BIOMED MATER RES, V30, P463, DOI 10.1002/(SICI)1097-4636(199604)30:4<463::AID-JBM4>3.0.CO
[4]  
2-N
[5]  
Goodman SB, 1996, J BIOMED MATER RES, V31, P421, DOI 10.1002/(SICI)1097-4636(199607)31:3<421::AID-JBM17>3.0.CO
[6]  
2-L
[7]   Serum levels of osteoprotegerin and receptor activator of nuclear factor-κB ligand as markers of periprosthetic osteolysis [J].
Granchi, Donatella ;
Pellacani, Andrea ;
Spina, Mauro ;
Cenni, Elisabetta ;
Savarino, Lucia Maria ;
Baldini, Nicola ;
Giunti, Armando .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (07) :1501-1509
[8]   THE DIFFERENCES IN TOXICITY AND RELEASE OF BONE-RESORBING MEDIATORS INDUCED BY TITANIUM AND COBALT-CHROMIUM-ALLOY WEAR PARTICLES [J].
HAYNES, DR ;
ROGERS, SD ;
HAY, S ;
PEARCY, MJ ;
HOWIE, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06) :825-834
[9]   The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses [J].
Heisel, C ;
Silva, M ;
Skipor, AK ;
Jacobs, JJ ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (04) :781-787
[10]   STUDIES OF THE MECHANISM BY WHICH THE MECHANICAL FAILURE OF POLYMETHYLMETHACRYLATE LEADS TO BONE-RESORPTION [J].
HOROWITZ, SM ;
DOTY, SB ;
LANE, JM ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06) :802-813