Nonlinearities in the response of beam position monitors for the LEP spectrometer

被引:2
|
作者
Matheson, J [1 ]
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
关键词
beam position monitor; beam energy measurement; relativistic beams;
D O I
10.1016/S0168-9002(01)00256-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The LEP Spectrometer determines the energy of the beam by measuring the bending angle due to a dipole magnet. using a total of six beam position monitors (BPM). The response to an off-centre beam of a BPM is not strictly linear with displacement and, in addition, depends on the size of the beam. The response also depends on the shape of the aperture of the BPM itself, since the inner surface is conducting and must therefore be an equipotential. For the LEP Spectrometer, BPM nonlinearities may become large enough to affect the beam energy measurement. We calculate the size of the effect for Gaussian beams within circular and elliptical apertures, drawing conclusions regarding the operation of the Spectrometer. (C) 2001 Elsevier Science B.V, All rights reserved.
引用
收藏
页码:436 / 447
页数:12
相关论文
共 50 条
  • [41] New generation electronics applied to beam position monitors
    Unser, KB
    BEAM INSTRUMENTATION - PROCEEDINGS OF THE SEVENTH WORKSHOP, 1997, (390): : 527 - 535
  • [42] Simulation of PEP-II beam position monitors
    Ng, CK
    Weiland, T
    Martin, D
    Smith, S
    Kurita, N
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 2485 - 2487
  • [43] Characterization of beam position monitors for measurement of second moment
    Russell, SJ
    Gilpatrick, JD
    Power, JF
    Shurter, RB
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 2580 - 2582
  • [44] Beam position monitors for the Linear Coherent Light Source
    Carr, R
    Hettel, R
    Martin, D
    Field, C
    FREE ELECTRON LASERS 1998, 1999, : II51 - II52
  • [45] Triangle and concave pentagon electrodes for an improved broadband frequency response of stripline beam position monitors
    Shobuda, Yoshihiro
    Chin, Yong Ho
    Takata, Koji
    Toyama, Takeshi
    Nakamura, Keigo
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2016, 19 (02):
  • [46] New methods of beam position monitors for measurement of quadrupole component
    Li, Peng
    Sun, Bao-Gen
    Luo, Qing
    Wang, Xiao-Hui
    Lu, Ping
    Xu, Hong-Liang
    Fang, Jia
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2008, 20 (04): : 573 - 578
  • [47] New methods of measuring emittance using beam position monitors
    Li, P.
    Sun, B. G.
    Luo, Q.
    Wang, X. H.
    Xu, H. L.
    Lu, P.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1675 - +
  • [48] Electromagnetic modeling of beam position and phase monitors for SNS linac
    Kurennoy, SS
    BEAM INSTRUMENTATION WORKSHOP 2000, 2000, 546 : 283 - 291
  • [49] Diode readout electronics for beam intensity and position monitors for FELs
    Herrmann, S.
    Hart, P.
    Freytag, M.
    Pines, J.
    Weaver, M.
    Sapozhnikov, L.
    Nelson, S.
    Koglin, J.
    Carini, G. A.
    Tomada, A.
    Haller, G.
    17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
  • [50] Alignment of beam position monitors in cryomodule of CADS injector II
    Yuan, Jian-Dong
    He, Yuan
    Zhang, Bin
    Zhang, Jun-Hui
    Wu, Jun-Xia
    Zhang, Yong
    Wang, Feng-Feng
    Yao, Jun-Jie
    Sun, Guo-Zhen
    Wan, Yu-Qin
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (06)