Nonlinearities in the response of beam position monitors for the LEP spectrometer

被引:2
|
作者
Matheson, J [1 ]
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
关键词
beam position monitor; beam energy measurement; relativistic beams;
D O I
10.1016/S0168-9002(01)00256-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The LEP Spectrometer determines the energy of the beam by measuring the bending angle due to a dipole magnet. using a total of six beam position monitors (BPM). The response to an off-centre beam of a BPM is not strictly linear with displacement and, in addition, depends on the size of the beam. The response also depends on the shape of the aperture of the BPM itself, since the inner surface is conducting and must therefore be an equipotential. For the LEP Spectrometer, BPM nonlinearities may become large enough to affect the beam energy measurement. We calculate the size of the effect for Gaussian beams within circular and elliptical apertures, drawing conclusions regarding the operation of the Spectrometer. (C) 2001 Elsevier Science B.V, All rights reserved.
引用
收藏
页码:436 / 447
页数:12
相关论文
共 50 条
  • [1] Nonlinearities in the response of beam position monitors
    Assmann, R
    Dehning, B
    Matheson, J
    Prochnow, J
    BEAM INSTRUMENTATION WORKSHOP 2000, 2000, 546 : 267 - 274
  • [2] Nonlinearities and effects of transverse beam size in beam position monitors
    Kurennoy, SS
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2001, 4 (09): : 17 - 24
  • [3] DEVELOPMENT OF BEAM PROFILE AND FAST POSITION MONITORS FOR THE LEP INJECTOR LINACS
    JUNG, R
    COLCHESTER, RJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 1917 - 1919
  • [4] Nonlinearities and effects of transverse beam size in beam position monitors (vol 4, art no 092801, 2001)
    Kurennoy, SS
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2003, 6 (03):
  • [5] Intensive beam monitors of the FODS spectrometer
    A. A. Volkov
    V. P. Efremov
    N. S. Ivanova
    A. Yu. Kalinin
    A. V. Korablev
    A. V. Koshelev
    A. N. Krinitsyn
    V. I. Kryshkin
    N. V. Kulagin
    A. F. Luk’yantsev
    S. V. Makonin
    A. A. Matyushin
    V. P. Milyutkin
    Yu. A. Mishagin
    V. S. Seleznev
    V. V. Skvortsov
    A. Yu. Sotnikov
    V. V. Talov
    L. K. Turchanovich
    Instruments and Experimental Techniques, 2012, 55 : 167 - 173
  • [6] Intensive beam monitors of the FODS spectrometer
    Volkov, A. A.
    Efremov, V. P.
    Ivanova, N. S.
    Kalinin, A. Yu.
    Korablev, A. V.
    Koshelev, A. V.
    Krinitsyn, A. N.
    Kryshkin, V. I.
    Kulagin, N. V.
    Luk'yantsev, A. F.
    Makonin, S. V.
    Matyushin, A. A.
    Milyutkin, V. P.
    Mishagin, Yu. A.
    Seleznev, V. S.
    Skvortsov, V. V.
    Sotnikov, A. Yu.
    Talov, V. V.
    Turchanovich, L. K.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2012, 55 (02) : 167 - 173
  • [7] Cavity beam position monitors
    Lorenz, R
    BEAM INSTRUMENTATION WORKSHOP, 1998, 451 : 53 - 73
  • [8] The calibration of BEPC beam position monitors
    Ye, K
    Ma, L
    Huang, H
    BEAM INSTRUMENTATION WORKSHOP, 1998, 451 : 303 - 309
  • [9] Signal processing for beam position monitors
    Vismara, G
    BEAM INSTRUMENTATION WORKSHOP 2000, 2000, 546 : 36 - 60
  • [10] Calibration of KEKB beam position monitors
    Satoh, K
    Tejima, M
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 2087 - 2089