Four years of LC-MS/MS method for quantification of 25-hydroxyvitamin D (D2+D3) for clinical practice

被引:9
作者
Meunier, Cecile [1 ]
Monteremal, Julien [1 ]
Faure, Patrice [1 ]
Ducros, Veronique [1 ]
机构
[1] Univ Hosp Ctr, Dept Biochem Toxicol & Pharmacol, Unit Hormone & Nutr, Grenoble, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 989卷
关键词
Vitamin D; Mass spectrometry; High throughput; Clinical practice; TANDEM MASS-SPECTROMETRY; PRESSURE CHEMICAL-IONIZATION; VITAMIN-D METABOLITES; HUMAN SERUM; D ASSAYS; C-3; EPIMER; D-3; PERFORMANCE;
D O I
10.1016/j.jchromb.2015.02.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Many methods for routine total plasma/serum 25-hydroxyvitamin D (25OHD) measurements are available from automated immunoassays to the most specific LC-MS/MS techniques. These last ones are nowadays numerous, still perfectible but more powerful than immunoassays in specific illnesses. We presented a robust method for simple quantification of 25-hydroxyvitamin D-2 (25OHD(2)) and 25-hydroxyvitamin D-3 (25OHD(3)) in human plasma by LC-APCI-MS/MS. This method is reliable and easy to perform for clinical measurements as we report a 4-year of clinical laboratory use. A brief off-line sample pretreatment (protein precipitation with addition of the internal standard) was realized then the supernatant was loaded into 96-well plates and analyzed by an online SPE-LC/MS/MS method on an APCI mode. 25OHD(2) and 25OHD(3) were both measured. The chromatographic system was thought and optimized for providing a dedicated line for this measurement on a shared instrument. The linearity was tested up to 380 nmol/L for both 25OHD(2) and 25OHD(3). The limit of quantification (LOQ) was 7 and 8 nmol/L for 25OHD(3) and 25OHD(2), respectively. Routine imprecision and bias were found in agreement with recommended limits for routine testing, CV <= 10% and bias <= 5%. Since July 2010, our participation to DEQAS was successfully validated. This simple robust online SPE-LC/MS/MS method is suitable for routine measurement of 25OHD(2) and 25OHD(3) in human adult plasma. The assay operates for 4 years and has performed more than 40,000 patient samples on a shared instrument. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 61
页数:8
相关论文
共 34 条
[1]   Development and comparison of three liquid chromatography-atmospheric pressure chemical ionization/mass spectrometry methods for determining vitamin D metabolites in human serum [J].
Bedner, Mary ;
Phinney, Karen W. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1240 :132-139
[2]   Current status of clinical 25-hydroxyvitamin D measurement: An assessment of between-laboratory agreement [J].
Binkley, Neil ;
Krueger, Diane C. ;
Morgan, Sarah ;
Wiebe, Donald .
CLINICA CHIMICA ACTA, 2010, 411 (23-24) :1976-1982
[3]   Determination of serum vitamins 25-OH-D2 and 25-OH-D3 with liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray source and core-shell or sub-2 μm particle columns: A comparative study [J].
Bogusz, Maciej J. ;
Al Enazi, Eid ;
Tahtamoni, Monther ;
Jawaad, Jamil Abdel ;
Al Tufail, Mohammed .
CLINICAL BIOCHEMISTRY, 2011, 44 (16) :1329-1337
[4]   Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method [J].
Chen, Huiping ;
McCoy, Leslie F. ;
Schleicher, Rosemary L. ;
Pfeiffer, Christine M. .
CLINICA CHIMICA ACTA, 2008, 391 (1-2) :6-12
[5]   Variability in the analysis of 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry: The devil is in the detail [J].
Couchman, Lewis ;
Benton, Christopher M. ;
Moniz, Cajetan F. .
CLINICA CHIMICA ACTA, 2012, 413 (15-16) :1239-1243
[6]   Variation in clinical vitamin D status by DiaSorin Liaison and LC-MS/MS in the presence of elevated 25-OH vitamin D2 [J].
de Koning, Lawrence ;
Al-Turkrnani, M. Rabie ;
Berg, Anders H. ;
Shkreta, Aida ;
Law, Terence ;
Kellogg, Mark D. .
CLINICA CHIMICA ACTA, 2013, 415 :54-58
[7]   Accuracy of three automated 25-hydroxyvitamin D assays in hemodialysis patients [J].
Depreter, Barbara ;
Heijboer, Annemieke C. ;
Langlois, Michel R. .
CLINICA CHIMICA ACTA, 2013, 415 :255-260
[8]   A robust liquid chromatography tandem mass spectrometry method for total plasma homocysteine determination in clinical practice [J].
Ducros, Veronique ;
Belva-Besnet, Helene ;
Casetta, Bruno ;
Favier, Alain .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (08) :987-990
[9]   Quantitative determination of plasma vitamin K1 by high-performance liquid chromatography coupled to isotope dilution tandem mass spectrometry [J].
Ducros, Veronique ;
Pollicand, Mickael ;
Laporte, Francois ;
Favier, Alain .
ANALYTICAL BIOCHEMISTRY, 2010, 401 (01) :7-14
[10]   Determination of dansylated polyamines in red blood cells by liquid chromatography-tandem mass spectrometry [J].
Ducros, Veronique ;
Ruffieux, Daniel ;
Belva-Besnet, Helene ;
de Fraipont, Florence ;
Berger, Francois ;
Favier, Alain .
ANALYTICAL BIOCHEMISTRY, 2009, 390 (01) :46-51