A non-contact approach for PWV detection: application in a clinical setting

被引:5
|
作者
Campo, Adriaan [1 ,3 ]
Heuten, Hilde [2 ]
Goovaerts, Inge [2 ]
Ennekens, Guy [2 ]
Vrints, Christiaan [2 ]
Dirckx, Joris [1 ]
机构
[1] Univ Antwerp, Lab Biomed Phys, Fac Sci, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
[2] Univ Antwerp Hosp, Dept Cardiol, Wilrijkstr 10, B-2650 Edegem, Belgium
[3] Columbia Univ, Dept Biomed Engn, Ultrasound Elast Imaging Lab, 630 West 168th St, New York, NY 10032 USA
关键词
arteriosclerosis; laser Doppler vibrometry; pulse wave velocity; PULSE-WAVE VELOCITY; CAROTID ARTERIAL STIFFNESS; LEFT-VENTRICULAR HYPERTROPHY; EXPERT CONSENSUS DOCUMENT; INTIMA-MEDIA THICKNESS; ALL-CAUSE MORTALITY; AORTIC STIFFNESS; BLOOD-PRESSURE; RISK; STROKE;
D O I
10.1088/0967-3334/37/7/990
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A need for screening methods for arteriosclerosis led to the development of several approaches to measure pulse wave velocity (PWV) being indicative of arterial stiffness. Carotid-femoral PWV (cfPWV) can be measured between common carotid artery (CCA) and femoral artery (FA) displaying the physiologically important stiffness of the conduit arteries. However, this measurement approach has several disadvantages, and a local PWV-measurement of CCA-stiffness has been proposed as an alternative in the past. In the presented pilot study, laser Doppler vibrometry (LDV) is used to measure PWV locally in the CCA (PWVLDV) in 48 patients aged between 48 and 70, with known atherosclerotic arterial disease: stabilized coronary artery disease (CAD), cerebro-vascular disease (CVD) or peripheral artery disease (PAD). Additionally, cfPWV, CCA distensibility coefficient (DC), CCA intima-media thickness (IMT), blood pressure (BP) and age were evaluated. LDV is a valid method for local PWV-measurement. The method is potentially easy to use, and causes no discomfort to the patient. PWVLDV correlates with age (R = 0.432; p = 0.002) as reported in related studies using other techniques, and measured values lay between 2.5 and 5.8 m s(-1), which is well in line with literature measures of local PWV in the CCA. In conclusion, PWVLDV potentially is a marker for arterial health, but more research in a larger and more homogeneous patient population is mandatory. In future studies, blood velocity measurements should be incorporated, as well as a reference method such as pulse wave imaging (PWI) or magnetic resonance imaging (MRI).
引用
收藏
页码:990 / 1003
页数:14
相关论文
共 50 条
  • [1] Laser system for non-contact tool setting and breakage detection
    Reiser, W
    LASER METROLOGY AND MACHINE PERFORMANCE III, 1997, : 33 - 42
  • [2] Design and application of bridge crack non-contact detection system
    Yao, Bing
    Zhao, Qilin
    Li, Fei
    Chen, Haosen
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 1071 - 1077
  • [3] Application of non-contact magnetic corresponding on the detection for natural gas pipeline
    Zeng, Weiguo
    Dang, Xiaofeng
    Li, Shuhua
    Wang, Hongmei
    Wang, Hao
    Wang, Bo
    2020 INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND BIOENGINEERING (ICEEB 2020), 2020, 185
  • [5] NON-CONTACT VIDEO DETECTION OF TONIC-CLONIC SEIZURES IN A RESIDENTIAL CARE SETTING
    Geertsema, E.
    Gutter, T.
    Vledder, B.
    Arends, J.
    Leijten, F.
    Thijs, R.
    Visser, G.
    Kalitzin, S.
    EPILEPSIA, 2017, 58 : S96 - S96
  • [6] CLINICAL EVALUATION OF NON-CONTACT TONOMETER
    WITTENBERG, S
    JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 1977, 48 (02) : 196 - 207
  • [7] Fatigue Detection based on Non-Contact Respiratory Detection
    Chen, Xing
    Su, Lumei
    Xu, Ming
    Deng, Bo
    Zhu, Yuanxuan
    THIRTEENTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2020), 2021, 11605
  • [8] Application of Laser Ultrasonic Technique for Non-contact Detection of Angled Surface Defects
    Guo Ruipeng
    Liu Jinghua
    Wang Haitao
    Transactions of Nanjing University of Aeronautics and Astronautics, 2018, 35 (05) : 858 - 865
  • [9] Application of a non-contact laser ultrasonic imaging technique in surface defect detection
    Zeng, Wei
    Wang, Hai-tao
    Tian, Gui-yun
    Hu, Guo-xing
    Yang, Xian-ming
    Wan, Min
    2014 IEEE FAR EAST FORUM ON NONDESTRUCTIVE EVALUATION/TESTING (FENDT), 2014, : 30 - 33
  • [10] Application of Laser Ultrasonic Technique for Non-contact Detection of Angled Surface Defects
    Guo R.
    Liu J.
    Wang H.
    Transactions of Nanjing University of Aeronautics and Astronautics, 2018, 35 (05) : 858 - 865