Factors affecting the measurement accuracy of ITER neutron activation system

被引:2
|
作者
Cheon, M. S. [1 ]
Ahn, Y. H. [1 ]
Pak, S. [1 ]
Seon, C. [1 ]
Krasilnikov, V. [2 ]
Bertalot, L. [2 ]
机构
[1] Natl Fus Res Inst, Gwahakro 169148, Daejeon, South Korea
[2] ITER Org, St Paul Les Durance, France
来源
JOURNAL OF INSTRUMENTATION | 2017年 / 12卷
关键词
Neutron detectors (cold; thermal; fast neutrons); Nuclear instruments and methods for hot plasma diagnostics;
D O I
10.1088/1748-0221/12/08/C08009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the main purposes of the ITER2 neutron activation system (NAS) is to evaluate the total neutron production rate from all over the plasma. The measurement accuracy depends on the position and profile of the plasma and the material in front of the irradiation end. It is required to minimize the amount of material and its density variation across the field of view between the plasma and the irradiation end. Due to the radiation and thermal environment of the ITER in-vessel, however, the measurement from ITER NAS cannot avoid the strong influence from in-vessel materials such as the diagnostic first wall, blanket modules, and divertor cassettes, those are located near the irradiation ends. In order to improve the reliability of the measurement in such environment, special cutouts in the diagnostic first wall are introduced near the irradiation end structures located in the port plugs. The effect of the materials and the position and profile of the neutron source in the plasma are evaluated for these irradiation locations, as well as the ones under the divertor cassettes and between blanket modules, by the neutron transport calculation. Calculation results show that simultaneous measurements at upper port and divertor location can provide highly accurate results even without a position or profile correction from other diagnostics.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Disscuss on factors affecting phase measurement accuracy in acousto-optic phase processor
    Szustakowski, M
    Jodlowski, L
    Bobrowicz, R
    ACOUSTO-OPTICS AND APPLICATIONS IV, 2001, 4514 : 153 - 159
  • [42] Factors affecting the accuracy and reliability of the measurement of anti-Mullerian hormone concentration in the clinic
    Fu, Yun-Xing
    Wang, Hui
    Hu, Ting
    Wang, Fei-Miao
    Hu, Rong
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (05)
  • [43] FACTORS AFFECTING THE ACCURACY OF REFERENCE ELECTRODES
    ANSUINI, FJ
    DIMOND, JR
    MATERIALS PERFORMANCE, 1994, 33 (11) : 14 - 17
  • [44] Factors Affecting the Accuracy of Reference Electrodes
    Ansuini, Frank J.
    Dimond, James R.
    MATERIALS PERFORMANCE, 2017, 56 (10) : 30 - 33
  • [45] FACTORS AFFECTING VISUAL INSPECTION ACCURACY
    MEGAW, ED
    APPLIED ERGONOMICS, 1979, 10 (01) : 27 - 32
  • [46] SITUATIONAL FACTORS AFFECTING FORECAST ACCURACY
    SCHNAARS, SP
    JOURNAL OF MARKETING RESEARCH, 1984, 21 (03) : 290 - 297
  • [47] Factors Affecting Insulin Dosing Accuracy
    Virdi, Naunihal S.
    Mahoney, John J.
    DIABETES, 2012, 61 : A589 - A589
  • [48] Factors Affecting Accuracy in Proton Therapy
    Cheng, C.
    Zhao, L.
    Zhao, Q.
    Moskvin, V.
    Buchsbaum, J.
    Das, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3771 - 3771
  • [49] Factors affecting SMD placement accuracy
    Amistar, San Marcos, United States
    Electron Packag Prod, 1 (5pp):
  • [50] Factors affecting the accuracy of TMA measurements
    Foreman, Jonathon
    Kelsey, Mark
    Widmann, Georg
    ASTM Special Technical Publication, (1369): : 181 - 196