摘要
One of the main purposes of the ITER2 neutron activation system (NAS) is to evaluate the total neutron production rate from all over the plasma. The measurement accuracy depends on the position and profile of the plasma and the material in front of the irradiation end. It is required to minimize the amount of material and its density variation across the field of view between the plasma and the irradiation end. Due to the radiation and thermal environment of the ITER in-vessel, however, the measurement from ITER NAS cannot avoid the strong influence from in-vessel materials such as the diagnostic first wall, blanket modules, and divertor cassettes, those are located near the irradiation ends. In order to improve the reliability of the measurement in such environment, special cutouts in the diagnostic first wall are introduced near the irradiation end structures located in the port plugs. The effect of the materials and the position and profile of the neutron source in the plasma are evaluated for these irradiation locations, as well as the ones under the divertor cassettes and between blanket modules, by the neutron transport calculation. Calculation results show that simultaneous measurements at upper port and divertor location can provide highly accurate results even without a position or profile correction from other diagnostics.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Neutron activation for ITER
    Barnes, CW
    Loughin, MJ
    Nishitani, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 577 - 580
  • [2] Neutron activation system using water flow for ITER
    Nishitani, T
    Ebisawa, K
    Kasai, S
    Walker, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1735 - 1738
  • [3] Development of the prototype pneumatic transfer system for ITER neutron activation system
    Cheon, M. S.
    Seon, C. R.
    Pak, S.
    Lee, H. G.
    Bertalot, L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [4] An investigation of various factors affecting measurement accuracy of the Tekscan seat pressure system
    Lu, HZ
    Lin, G
    PROCEEDINGS OF THE HUMAN FACTORS AND ERGONOMICS SOCIETY - 40TH ANNUAL MEETING, VOLS 1 AND 2: HUMAN CENTERED TECHNOLOGY - KEY TO THE FUTURE, 1996, : 1036 - 1040
  • [5] In-vessel design of ITER diagnostic neutron activation system
    Cheon, M. S.
    Pak, S.
    Lee, H. G.
    Bertalot, L.
    Walker, C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [6] Operational Radioactivity Evaluation of ITER Diagnostic Neutron Activation System
    Cheon, M. S.
    Seon, C. R.
    Pak, S.
    Lee, H. G.
    Bertalot, L.
    Forrest, R. A.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (03) : 274 - 277
  • [7] Preliminary study on capsule material for ITER neutron activation system
    Lee, Yuna
    Dang, Jeong-Jeung
    Jo, Jungmin
    Chung, Kyoung-Jae
    Hwang, Y. S.
    Cheon, M. S.
    Lee, H. G.
    Bertalot, L.
    FUSION ENGINEERING AND DESIGN, 2014, 89 (9-10) : 1894 - 1898
  • [8] Operational Activity Evaluation of ITER Diagnostic Neutron Activation System
    Cheon, M. S.
    Seon, C. R.
    Pak, S.
    Lee, H. G.
    Bertalot, L.
    Forrest, R. A.
    2009 23RD IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 2009, : 253 - +
  • [9] Neutron Activation System for the European ITER Test Blanket Modules
    Klix, Axel
    Fischer, Ulrich
    Gehre, Daniel
    Ghidhersa, Bradut-Eugen
    Tian, Kuo
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [10] SONOGRAPHIC MEASUREMENT OF THE FETAL FEMUR - FACTORS AFFECTING ACCURACY
    LESSOWAY, VA
    SCHULZER, M
    WITTMANN, BK
    JOURNAL OF CLINICAL ULTRASOUND, 1990, 18 (06) : 471 - 476