Three-dimensional prediction of roots position through cone-beam computed tomography scans-digital model superimposition: A novel method

被引:32
作者
Staderini, Edoardo [1 ,2 ]
Guglielmi, Federica [1 ]
Cornelis, Marie A. [2 ]
Cattaneo, Paolo M. [2 ]
机构
[1] Univ Cattolica Sacro Cuore, Fdn Policlin Univ A Gemelli IRCCS, Inst Dent, Rome, Italy
[2] Aarhus Univ, Sect Orthodont, Dept Dent & Oral Hlth, Aarhus, Denmark
关键词
cone-beam computed tomographic; image segmentation; intra-oral scans; orthodontics; three-dimensional imaging; MESIODISTAL ANGULATION; TOOTH; INCLINATION; RELIABILITY; ACCURACY; MOVEMENT; CANINES;
D O I
10.1111/ocr.12252
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Structured Abstract Objectives To introduce a new, fast, reliable, and free from software-related bias method to predict three-dimensionally the root position and angulation during and after orthodontic treatment. The final goal is to keep to a minimum the use of ionizing radiation by eliminating the necessity of multiple radiation exposure for checking root alignment. Setting and Sample Population Pre- and post-treatment digital models and cone-beam computed tomographic (CBCT) scans from a patient were retrieved. Material and Methods The post-treatment digital model (post-model) was set as the reference; pre- and post-treatment CBCT scans were pre-aligned to the post-model with a point set registration; iterative closest point algorithm was then employed for final adjustments. The accuracy of the proposed method was assessed by comparing the average distance between the expected root position setup with the true position of the roots, as from the post-treatment CBCT. Results After crown superimposition, 3D colour maps showed that the accuracy of the root prediction was below 0.1 mm. Conclusion The proposed digital workflow allows to predict in an accurate and truly three-dimensional way the final position of roots, when an initial CBCT is available, without the need of an extra X-ray examination for the patient at the end of treatment. The limitation of the exposure to mid- and post-treatment X-rays is in accordance with the ALARA (As Low As Reasonably Achievable) principle and it is even more relevant in growing patients.
引用
收藏
页码:16 / 23
页数:8
相关论文
共 33 条
[1]  
BERT JD, 1981, DENT CLIN N AM, V25, P85
[2]   CROWN-ROOT ANGLES OF UPPER CENTRAL INCISORS [J].
CARLSSON, R ;
RONNERMAN, A .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1973, 64 (02) :147-154
[3]   Transversal maxillary dento-alveolar changes in patients treated with active and passive self-ligating brackets: a randomized clinical trial using CBCT-scans and digital models [J].
Cattaneo, P. M. ;
Treccani, M. ;
Carlsson, K. ;
Thorgeirsson, T. ;
Myrda, A. ;
Cevidanes, L. H. S. ;
Melsen, B. .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2011, 14 (04) :222-233
[4]   Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts [J].
de Waard, Olivier ;
Rangel, Frits Andreas ;
Fudalej, Piotr Stanislaw ;
Bronkhorst, Ewald Maria ;
Kuijpers-Jagtman, Anne Marie ;
Breuning, Karel Hero .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (03) :328-336
[5]   How to report reliability in orthodontic research: Part 2 [J].
Donatelli, Richard E. ;
Lee, Shin-Jae .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (02) :315-318
[6]   Orthodontic measurements on digital study models compared with plaster models: a systematic review [J].
Fleming, P. S. ;
Marinho, V. ;
Johal, A. .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2011, 14 (01) :1-16
[7]   Cone-beam computed tomography for routine orthodontic treatment planning: A radiation dose evaluation [J].
Garcia Silva, Maria Alves ;
Wolf, Ulrich ;
Heinicke, Frank ;
Bumann, Axel ;
Visser, Heiko ;
Hirsch, Edgar .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) :640.e1-640.e5
[8]   Effect of buccolingual root angulation on the mesiodistal angulation shown on panoramic radiographs [J].
Garcia-Figueroa, Mariano A. ;
Raboud, Donald W. ;
Lam, Ernest W. ;
Heo, Giseon ;
Major, Paul W. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (01) :93-99
[9]  
Garib Daniela G., 2014, Dental Press J. Orthod., V19, P136, DOI 10.1590/2176-9451.19.5.136-149.sar
[10]   Accuracy in tooth positioning with a fully customized lingual orthodontic appliance [J].
Grauer, Dan ;
Proffit, William R. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (03) :433-443