Homogenous nuclear magnetic resonance probe using the space harmonics suppression method

被引:3
作者
de Pellegars, Pauline [1 ,2 ]
Pan, Liu [1 ]
Sidi-Boulenouar, Rahima [1 ,3 ]
Nativel, Eric [4 ]
Zanca, Michel [1 ,5 ]
Alibert, Eric [1 ]
Rousset, Sebastien [1 ]
Cardoso, Maida [1 ]
Verdeil, Jean-Luc [3 ]
Bertin, Nadia [6 ]
Goze-Bac, Christophe [1 ]
Muller, Julien [2 ]
Schimpf, Remy [2 ]
Coillot, Christophe [1 ]
机构
[1] Univ Montpellier, CNRS, Lab Charles Coulomb L2C UMR5221, Pl EugeneBataillon, Montpellier, France
[2] RS2D, 13 Rue Vauban, F-67450 Mundolsheim, France
[3] UMR AGAP, Ctr Cooperat Int Rech Agron Dev CIRAD, Montpellier, France
[4] Univ Montpellier, UMR5214, IES, Campus St Priest, F-34095 Montpellier, France
[5] Univ Hosp Montpellier, CMC Gui Chauliac, Nucl Med, F-34095 Montpellier, France
[6] INRA, PSH UR 1115, Avignon, France
关键词
COIL;
D O I
10.5194/jsss-9-117-2020
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nuclear magnetic resonance imaging (MRI) has became an unavoidable medical tool in spite of its poor sensitivity. This fact motivates the efforts to enhance the nuclear magnetic resonance (NMR) probe performance. Thus, the nuclear spin excitation and detection, classically performed using radio-frequency coils, are required to be highly sensitive and homogeneous. The space harmonics suppression (SHS) method, already demonstrated to construct coil producing homogenous static magnetic field, is used in this work to design radio-frequency coils. The SHS method is used to determine the distribution of the electrical conductive wires which are organized in a saddle-coil-like configuration. The theoretical study of these SHS coils allows one to expect an enhancement of the signal-to-noise ratio with respect to saddle coil. Coils prototypes were constructed and tested to measure H-1 NMR signal at a low magnetic field (8 mT) and perform MRI acquired at a high magnetic field (3 T). The signal-to-noise ratios of these SHS coils are compared to the one of saddle coil and birdcage (in the 3 T case) of the same size under the same pulse sequence conditions demonstrating the performance enhancement allowed by the SHS coils.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 11 条
[1]  
BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
[2]   HADAMARD SPECTROSCOPIC IMAGING (HSI) FOR MULTIVOLUME LOCALIZATION [J].
BOLINGER, L ;
LEIGH, JS .
JOURNAL OF MAGNETIC RESONANCE, 1988, 80 (01) :162-167
[3]   A new method for obtaining a uniform magnetic field [J].
Clark, JW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1938, 9 (10) :320-322
[4]   The magnetic field homogeneity of coils by means of the space harmonics suppression of the current density distribution [J].
Coillot, Christophe ;
Nativel, Eric ;
Zanca, Michel ;
Goze-Bac, Christophe .
Journal of Sensors and Sensor Systems, 2016, 5 (02) :401-408
[5]   Signal modeling of an MRI ribbon solenoid coil dedicated to spinal cord injury investigations [J].
Coillot, Christophe ;
Sidiboulenouar, Rahima ;
Nativel, Eric ;
Zanca, Michel ;
Alibert, Eric ;
Cardoso, Maida ;
Saintmartin, Guillaume ;
Noristani, Harun ;
Lonjon, Nicolas ;
Lecorre, Marine ;
Perrin, Florence ;
Goze-Bac, Christophe .
JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2016, 5 (01) :137-145
[6]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[7]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85
[8]   Correlation theories of stationary stochastic processes. [J].
Khintchine, A .
MATHEMATISCHE ANNALEN, 1934, 109 :604-615
[9]  
Mispelter J., 2006, NMR PROBEHADS BIOPHY
[10]  
Sidi-Boulenouar R., 2018, PHYSICS