In vivo three-dimensional patellar tracking on the femur

被引:27
作者
Asano, T
Akagi, M
Koike, K
Nakamura, T
机构
[1] Loma Linda Univ, Dept Orthopaed Surg, Peterson Tribol Lab, San Bernardino, CA 92408 USA
[2] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, Kyoto, Japan
[3] Kinki Univ, Fac Med, Dept Orthopaed Surg, Osaka, Japan
关键词
D O I
10.1097/01.blo.0000072905.36018.30
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In vivo three-dimensional patellar tracking under weightbearing conditions was investigated with the principal reference axes of the femur in the coronal and axial planes, using a biplanar image-matching technique. Three-dimensional knee models of eight healthy volunteers were constructed using computed tomography scanning. Projection images of the models were fitted onto anteroposterior and lateral radiographs of the knees at hyperextension and at every 15degrees from 0degrees to 120degrees flexion. Knee motion then was reconstructed on a computer. Patellar tracking during knee flexion was described simply with a medial jerk shift of 8 mm in early flexion until 30degrees and a linear tracking with minimal mediolateral translation. The linear tracking portion was located laterally 5 mm from the mediolateral center of the femoral condyles. On average, the direction of this linear tracking was almost perpendicular to the distal condylar line in the coronal plane and perpendicular to the posterior condylar axis in the axial plane. These results help improve the understanding of patello-femoral kinematics and provide useful information for the design and positioning of the prostheses used in total knee arthroplasty.
引用
收藏
页码:222 / 232
页数:11
相关论文
共 38 条
  • [1] Akagi M, 1999, CLIN ORTHOP RELAT R, P155
  • [2] ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, P170
  • [3] In vivo three-dimensional knee kinematics using a biplanar image-matching technique
    Asano, T
    Akagi, M
    Tanaka, K
    Tamura, J
    Nakamura, T
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 157 - 166
  • [4] In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties
    Banks, SA
    Markovich, GD
    Hodge, WA
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (03) : 297 - 304
  • [5] BARINK M, 2002, T ORTHOP RES SOC, V48, P895
  • [6] Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
  • [7] Barrack RL, 2001, CLIN ORTHOP RELAT R, P62
  • [8] BERGER RA, 1993, CLIN ORTHOP RELAT R, P40
  • [9] Malrotation causing patellofemoral complications after total knee arthroplasty
    Berger, RA
    Crossett, LS
    Jacobs, JJ
    Rubash, HE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) : 144 - 153
  • [10] Symmetry versus asymmetry in the design of total knee femoral components - An unresolved controversy
    Bindelglass, DF
    Dorr, LD
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (08) : 939 - 944