A novel mechanism for exhaust steam waste heat recovery in combined heat and power unit

被引:53
作者
Zhao, Shifei [1 ]
Ge, Zhihua [1 ]
He, Jie [1 ]
Wang, Chunlan [1 ]
Yang, Yongping [1 ]
Li, Peifeng [2 ]
机构
[1] North China Elect Power Univ, Natl Thermal Power Engn & Technol Res Ctr, Beijing 102206, Peoples R China
[2] Beijing Municipal Inst City Planning & Design, Beijing 100045, Peoples R China
关键词
CHP; Energy saving; Exhaust steam utilization; Thermodynamic analysis; Techno-economic evaluation; THERMAL-ENERGY STORAGE; LOW-TEMPERATURE; SYSTEM; PLANT; OPTIMIZATION; MANAGEMENT; NETWORKS; CHINA; CHP;
D O I
10.1016/j.apenergy.2017.07.068
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Combined heat and power (CHP) has been identified as an important approach for fossil fuel utilization with high efficiency and pollutant concentration control. In this study, an optimized process for in-depth exhaust steam utilization was proposed to further exploit the energy saving potential of CHP unit. In the novel system, the utilization of the exhaust steam was combined with the heating process for air and condensate water, largely recovering the waste heat and leading to an improvement in the performance of the CHP unit. EBSILON Professional was used to build the model; and compared with the reference system, thermodynamic analysis and techno-economic evaluation were conducted to reveal the characteristics of the novel system. The results showed that, in the design condition, the exhaust steam utilization ratio in the novel system had a significant increment of 22.74% than that in the reference system, leading to a sharp increase of 16.26% in heating capacity and 0.83 MW in net electricity output, bringing about 5.06% improvement in net generating efficiency. Meanwhile, the net annual revenues of the novel system can reach 1.80 million USD. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:596 / 606
页数:11
相关论文
共 30 条
[1]  
Basu P, 2000, BOILER FURNACE DESIG
[2]   Evaluation of the cost of using power plant reject heat in low-temperature district heating and cooling networks [J].
Colmenar-Santos, Antonio ;
Rosales-Asensio, Enrique ;
Borge-Diez, David ;
Collado-Fernandez, Eduardo .
APPLIED ENERGY, 2016, 162 :892-907
[3]   Exergetic comparison of efficiency indicators for combined heat and power (CHP) [J].
Ertesvag, Ivar S. .
ENERGY, 2007, 32 (11) :2038-2050
[4]   Industrial waste heat utilization for low temperature district heating [J].
Fang, Hao ;
Xia, Jianjun ;
Zhu, Kan ;
Su, Yingbo ;
Jiang, Yi .
ENERGY POLICY, 2013, 62 :236-246
[5]   Optimization of combined heat and power production with heat storage based on sliding time window method [J].
Fang, Tingting ;
Lahdelma, Risto .
APPLIED ENERGY, 2016, 162 :723-732
[6]   An assessment of solar-powered organic Rankine cycle systems for combined heating and power in UK domestic applications [J].
Freeman, James ;
Hellgardt, Klaus ;
Markides, Christos N. .
APPLIED ENERGY, 2015, 138 :605-620
[7]   Phase-change heat storage installation in combined heat and power plants for integration of renewable energy sources into power system [J].
Hu, Kang ;
Chen, Lei ;
Chen, Qun ;
Wang, Xiao-Hai ;
Qi, Jun ;
Xu, Fei ;
Min, Yong .
ENERGY, 2017, 124 :640-651
[8]   Experimental investigation and exergy analysis on thermal storage integrated micro-cogeneration system [J].
Johar, Dheeraj Kishor ;
Sharma, Dilip ;
Soni, Shyam Lal ;
Gupta, Pradeep K. ;
Goyal, Rahul .
ENERGY CONVERSION AND MANAGEMENT, 2017, 131 :127-134
[9]   A new utilization approach of the waste heat with mid-low temperature in the combined heating and power system integrating heat pump [J].
Kang, Shushuo ;
Li, Hongqiang ;
Lei, Jing ;
Liu, Lifang ;
Cai, Bo ;
Zhang, Guoqiang .
APPLIED ENERGY, 2015, 160 :185-193
[10]   Integrated multiscale simulation of combined heat and power based district heating system [J].
Li, Peifeng ;
Nord, Natasa ;
Ertesvag, Ivar Stale ;
Ge, Zhihua ;
Yang, Zhiping ;
Yang, Yongping .
ENERGY CONVERSION AND MANAGEMENT, 2015, 106 :337-354