Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

被引:55
作者
Lee, Wan-Sun [1 ]
Lee, Du-Hyeong [2 ]
Lee, Kyu-Bok [1 ,2 ]
机构
[1] Kyungpook Natl Univ, Adv Dent Device Dev Inst A3DI, Daegu, South Korea
[2] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, A3DI, 2177 Dalgubuldaero, Daegu 41940, South Korea
关键词
CAD/CAM milling system; 3D printing system; Interim crown; Fitness; PROVISIONAL RESIN CROWNS; POLYMERIZATION; INTEGRITY; ACCURACY;
D O I
10.4047/jap.2017.9.4.265
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) mu m for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) mu m, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 24 条
  • [1] Surface integrity of provisional resin materials
    Abouelatta, OB
    El-Bediwi, A
    Sakrana, A
    Jiang, XQ
    Blunt, L
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (03) : 584 - 591
  • [2] Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations
    Alharbi, Nawal
    Osman, Reham
    Wismeijer, Daniel
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06) : 760 - 767
  • [3] Correlation between polymerization shrinkage and marginal fit of temporary crowns
    Balkenhol, Markus
    Knapp, Michael
    Ferger, Paul
    Heun, Ulrich
    Woestmann, Bernd
    [J]. DENTAL MATERIALS, 2008, 24 (11) : 1575 - 1584
  • [4] Clinical fit of Procera AllCeram crowns
    Boening, KW
    Wolf, BH
    Schmidt, AE
    Kästner, K
    Walter, MH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) : 419 - 424
  • [5] Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: A pilot study
    Ehrenberg, D
    Weiner, GI
    Weiner, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03) : 230 - 236
  • [6] Changes in marginal gap size of provisional resin crowns after occlusal loading and thermal cycling
    Ehrenberg, DS
    Weiner, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (02) : 139 - 148
  • [7] Metal Additive Manufacturing: A Review
    Frazier, William E.
    [J]. JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2014, 23 (06) : 1917 - 1928
  • [8] FIT OF SINGLE TOOTH ZIRCONIA COPINGS: COMPARISON BETWEEN VARIOUS MANUFACTURING PROCESSES
    Grenade, Charlotte
    Mainjot, Amelie
    Vanheusden, Alain
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (04) : 249 - 255
  • [9] Heying JJ, 2009, THESIS
  • [10] In vitro evaluation of the marginal integrity of CAD/CAM interim crowns
    Khng, Kwang Yong Kelvin
    Ettinger, Ronald L.
    Armstrong, Steven R.
    Lindquist, Terry
    Gratton, David G.
    Qian, Fang
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) : 617 - 623