Determination of Myrtucommulone from Myrtus communis in Human and Rat Plasma by Liquid Chromatography/Tandem Mass Spectrometry

被引:10
|
作者
Gerbeth, Kathleen [1 ]
Meins, Juergen [1 ]
Werz, Oliver [2 ]
Schubert-Zsilavecz, Manfred [1 ,3 ]
Abdel-Tawab, Mona [1 ]
机构
[1] Cent Lab German Pharmacists, Dept Res & Dev, D-65760 Eschborn, Germany
[2] Univ Tubingen, Inst Pharmaceut, Dept Pharmaceut Analyt, Tubingen, Germany
[3] Goethe Univ Frankfurt, Inst Pharmaceut Chem, ZAFES, Frankfurt, Germany
关键词
myrtucommulone; myrtle; Myrtus communis - Myrtaceae; LC/MS; human/rat plasma; OLIGOMERIC ACYLPHLOROGLUCINOLS; FLUORESCENCE DETECTION; ULTRAVIOLET DETECTION; HYPERFORIN; HYPERICIN; PSEUDOHYPERICIN; EXTRACTS; BRAIN; WORT;
D O I
10.1055/s-0030-1250459
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Recent studies revealed that the non-prenylated acylphloroglucinol myrtucommulone (MC) from myrtle (Myrtus communis) potently suppresses the biosynthesis of eicosanoids by direct inhibition of cyclooxygenase-1, microsomal prostaglandin E2 synthase (mPGES)-1, and 5-lipoxygenase at IC(50) values in the range of 1 to 29 mu M. Moreover, MC showed potent efficacy in animal models of inflammation after intraperitoneal administration. Since the main prerequisite for therapeutic efficacy is sufficient bioavailability, it is important to evaluate whether the concentrations of MC achieved in plasma coincide with the pharmacological active concentrations determined in vitro. For that reason, a sensitive LC/MS/MS-method has been developed and validated for the determination of MC in human plasma. This method is based on liquid-liquid extraction of plasma samples with 20% ethyl acetate in tert-butyl methyl ether using the structurally related acyl-phloroglucinol hyperforin as the internal standard. Chromatographic separation was achieved on a Gemini C6 Phenyl column using a mixture of acetonitrile/water (85 : 15 v/v) containing 6 mM ammonium formate in a run time of 15 min at a flow rate of 1 mL/min, a column temperature of 40 degrees C, and an autosampler temperature of 5 degrees C. Mass spectrometric quantification was carried out in the negative ion mode using electrospray ionization (ESI) and multiple-reaction monitoring (MRM). The most intense [M - H](-) MRM transition at m/z 667.4 -> m/z 194.9 was used for quantification of MC and the transition at m/z 535.4 to m/z 383.2 was used to monitor hyperforin. The method was linear in the range of 1-100 ng/mL with r > 0.998, an intra- and inter-day RSD of 1.1-8.4 and 7.1-11.8%, respectively, and a maximum R. E. of 13.8% at the lowest concentration level. Moreover, cross validation revealed the suitability of the developed LC/MS method for application in rat studies.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 50 条
  • [11] Determination of typhaneoside in rat plasma by liquid chromatography-tandem mass spectrometry
    Chen, Peidong
    Liu, Shijia
    Dai, Guoliang
    Xie, Liyan
    Xu, Jie
    Zhou, Ling
    Ju, Wenzheng
    Ding, Anwei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 636 - 639
  • [12] Determination of fucoxanthinol in rat plasma by liquid chromatography-tandem mass spectrometry
    Zhang, Yiping
    Lin, Jinjing
    Yan, Guangyu
    Jin, Wenhui
    Chen, Weizhu
    Sun, Jipeng
    Yang, Longhe
    Huang, Mingqing
    Hong, Zhuan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 164 : 155 - 163
  • [13] Quantitative determination of sparfloxacin in rat plasma by liquid chromatography/tandem mass spectrometry
    Noh, Keumhan
    Kwon, Kwang-il
    Jeong, Tae Cheon
    Kang, Wonku
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (11) : 1199 - 1202
  • [14] Liquid chromatography-tandem mass spectrometry for the determination of jaceosidin in rat plasma
    Song, Won Young
    Kim, Nam Jin
    Kim, Sung Yeon
    Lee, Hye Suk
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (02) : 381 - 386
  • [15] Determination of gatifloxacin in human plasma by liquid chromatography/electrospray tandem mass spectrometry
    Vishwanathan, K
    Bartlett, MG
    Stewart, JT
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) : 915 - 919
  • [16] Determination of genistein and daidzein in human plasma by liquid chromatography and tandem mass spectrometry
    Yang, SM
    Zhou, X
    Xu, Y
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (03) : 481 - 499
  • [17] Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry
    Lee, HW
    Ji, HY
    Kim, HH
    Cho, HY
    Lee, YB
    Lee, HS
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02): : 395 - 400
  • [18] Determination of olanzapine in human plasma and serum by liquid chromatography tandem mass spectrometry
    Berna, M
    Shugert, R
    Mullen, J
    JOURNAL OF MASS SPECTROMETRY, 1998, 33 (10): : 1003 - 1008
  • [19] Determination of olprinone in human plasma utilizing liquid chromatography tandem mass spectrometry
    Zhu, Ping
    Wen, Yu-Guan
    Chen, Ji-Mei
    Zhuang, Jian
    Zhou, Zhi-Ling
    Zheng, Shao-Yi
    Wu, Ruo-Bin
    Xiao, Xue-Jun
    Lu, Cong
    Fan, Rui-Xin
    Guo, Hui-Ming
    Fan, Xiao-Ping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 198 - 202
  • [20] Determination of silodosin in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao, Xia
    Liu, Yuwang
    Xu, Junyu
    Zhang, Dan
    Zhou, Ying
    Gu, Jingkai
    Cui, Yimin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3724 - 3728