Iron-Based Superparamagnetic Nanoparticle Contrast Agents for MRI of Infection and Inflammation

被引:108
|
作者
Neuwelt, Alexander [1 ]
Sidhu, Navneet [1 ]
Hu, Chien-An A. [2 ]
Mlady, Gary [3 ]
Eberhardt, Steven C. [3 ]
Sillerud, Laurel O. [4 ]
机构
[1] Univ New Mexico, Sch Med, Dept Internal Med, Albuquerque, NM 87106 USA
[2] Univ New Mexico, Sch Med, Dept Biochem & Mol Biol, Albuquerque, NM 87106 USA
[3] Univ New Mexico, Sch Med, Dept Radiol, Albuquerque, NM 87106 USA
[4] Univ New Mexico, Sch Med, Dept Neurol, UNM BRaIN Ctr, Albuquerque, NM 87106 USA
关键词
ferumoxytol; infection; inflammation; macrophages; MRI; superparamagnetic iron oxide nanoparticles (SPIONs); ENHANCED MAGNETIC-RESONANCE; CHRONIC POSTTRAUMATIC OSTEOMYELITIS; ASYMPTOMATIC CAROTID ATHEROMA; CELL-ADHESION MOLECULE-1; CHRONIC KIDNEY-DISEASE; SOFT-TISSUE INFECTION; IN-VIVO; INTRAVENOUS IRON; MACROPHAGE INFILTRATION; ATHEROSCLEROTIC PLAQUE;
D O I
10.2214/AJR.14.12733
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. In this article, we summarize the progress to date on the use of superparamagnetic iron oxide nanoparticles (SPIONs) as contrast agents for MRI of inflammatory processes. CONCLUSION. Phagocytosis by macrophages of injected SPIONs results in a prolonged shortening of both T2 and T2* leading to hypointensity of macrophage-infiltrated tissues in contrast-enhanced MR images. SPIONs as contrast agents are therefore useful for the in vivo MRI detection of macrophage infiltration, and there is substantial research and clinical interest in the use of SPION-based contrast agents for MRI of infection and inflammation. This technique has been used to identify active infection in patients with septic arthritis and osteomyelitis; importantly, the MRI signal intensity of the tissue has been found to return to its unenhanced value on successful treatment of the infection. In SPION contrast-enhanced MRI of vascular inflammation, animal studies have shown decreased macrophage uptake in atherosclerotic plaques after treatment with statin drugs. Human studies have shown that both coronary and carotid plaques that take up SPIONs are more prone to rupture and that abdominal aneurysms with increased SPION uptake are more likely to grow. Studies of patients with multiple sclerosis suggest that MRI using SPIONs may have increased sensitivity over gadolinium for plaque detection. Finally, SPIONs have enabled the tracking and imaging of transplanted stem cells in a recipient host.
引用
收藏
页码:W302 / W313
页数:12
相关论文
共 50 条
  • [1] Development of iron-based MRI contrast agents
    Rivera-Millan, Lizmarie
    Gonzalez-Nieves, Karilys
    Lugo-Quintero, Adrian
    Gonzalez, Ricardo
    Raptis, Raphael G.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 924 - 924
  • [2] An Ounce of Caution: Superparamagnetic Iron Oxide Nanoparticle Based MRI Contrast Associated Anaphylaxis
    Heckman, A.
    Sacco, K.
    Agarwal, A.
    Hiroto, B.
    Guru, P. K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [3] Superparamagnetic iron oxide based MRI contrast agents: current status of clinical application
    Wang, Yi-Xiang J.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2011, 1 (01) : 35 - 40
  • [4] Peptide functionalized superparamagnetic iron oxide nanoparticles as MRI contrast agents
    Sulek, Selim
    Mammadov, Busra
    Mahcicek, Davut I.
    Sozeri, Huseyin
    Atalar, Ergin
    Tekinay, Ayse B.
    Guler, Mustafa O.
    JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (39) : 15157 - 15162
  • [5] Zinc superparamagnetic iron oxide nanoparticles for use as MRI contrast agents
    Barcena, Carlos
    Kherntong, Chalermchai
    Chaubey, Girija S.
    Kessinger, Chase W.
    Liu, J. Ping
    Gao, Jinming
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 49 - 50
  • [6] New Strategies to Prolong the In Vivo Life Span of Iron-Based Contrast Agents for MRI
    Antonelli, Antonella
    Sfara, Carla
    Battistelli, Serafina
    Canonico, Barbara
    Arcangeletti, Marcella
    Manuali, Elisabetta
    Salamida, Sonia
    Papa, Stefano
    Magnani, Mauro
    PLOS ONE, 2013, 8 (10):
  • [7] Calcium-sensitive MRI contrast agents based on superparamagnetic iron oxide nanoparticles and calmodulin
    Atanasijevic, Tatjana
    Shusteff, Maxim
    Fam, Peter
    Jasanoff, Alan
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (40) : 14707 - 14712
  • [8] New MRI contrast agents based on silicon nanotubes loaded with superparamagnetic iron oxide nanoparticles
    Gonzalez-Rodriguez, Roberto
    Granitzer, Petra
    Rumpf, Klemens
    Coffer, Jeffery L.
    ROYAL SOCIETY OPEN SCIENCE, 2018, 5 (08):
  • [9] A Targeted Iron-based MRI Contrast for Tumor Detection
    Mills, David R.
    Walsh, Edward G.
    Brilliant, Kate E.
    Hixson, Douglas C.
    Park, William K. C.
    FASEB JOURNAL, 2013, 27
  • [10] Experimental validation of proton transverse relaxivity models for superparamagnetic nanoparticle MRI contrast agents
    Carroll, Matthew R. J.
    Woodward, Robert C.
    House, Michael J.
    Teoh, Wey Yang
    Amal, Rose
    Hanley, Tracey L.
    St Pierre, Timothy G.
    NANOTECHNOLOGY, 2010, 21 (03)