摘要
Background: Tricuspid edge to edge repair (TEER) is a novel treatment for severe tricuspid regurgitation and is highly dependent on intraprocedural image quality. To date, transesophageal echocardiography (TEE) has been the primary imaging modality used to guide TEER. The role of intracardiac echocardiography (ICE) has not been assessed. The objective of this study was to describe the use and role of 2-dimensional ICE in the early experience of TEER. Methods: Consecutive patients undergoing TEER (with or without concomitant mitral repair) with off-label use of MitraClip (Abbott, Santa Clara, CA) were included in the study. Utilization of 2-dimensional ICE in comparison with TEE imaging were collected in each procedure through retrospective review of the procedural reports and images. Results: Of 42 TEER cases, ICE was used in 15 (36%) and concomitant mitral repair was performed in 37 (86%). ICE was increasingly used over time for TEER. ICE was able to visualize the tricuspid leaflets with high resolution and provided superior leaflet visualization to TEE in 40% of cases where it was used. Patients treated with ICE guidance tended to have a greater baseline severity of tricuspid regurgitation compared with patients treated with TEE guidance alone (8/15 [53%] massive or greater tricuspid regurgitation versus 6/27 [22%]; P=0.09). Degree of tricuspid regurgitation reduction was similar with TEE alone versus ICE plus TEE guidance (1.9 +/- 1.0 versus 2.1 +/- 1.1 grade reduction, P=0.28). Conclusions: ICE was increasingly used in the early experience of TEER over time. ICE facilitates leaflet visualization for grasping and is a useful adjunct to TEE during TEER.
引用
收藏
页码:1036 / 1043
页数:8
相关论文
共 16 条
[1]   Outcomes of Routine Intracardiac Echocardiography to Guide Left Atrial Appendage Occlusion [J].
Alkhouli, Mohamad ;
Chaker, Zakeih ;
Alqahtani, Fahad ;
Raslan, Saleem ;
Raybuck, Bryan .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (04) :393-400
[2]   Complementary roles of intracardiac and transoesophageal echocardiography in transcatheter tricuspid interventions [J].
Alkhouli, Mohamad ;
Eleid, Mackram F. ;
Michellena, Hector ;
Pislaru, Sorin V. .
EUROINTERVENTION, 2020, 15 (17) :1514-1515
[3]   Intracardiac Echocardiography in Structural Heart Disease Interventions [J].
Alkhouli, Mohamad ;
Hijazi, Ziyad M. ;
Holmes, David R., Jr. ;
Rihal, Charanjit S. ;
Wiegers, Susan E. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (21) :2133-2147
[4]   Intracardiac Echocardiography as Sole Guidance for the MitraClip Procedure [J].
Amat-Santos, Ignacio J. ;
Serrador, Ana ;
Arnold, Roman J. .
REVISTA ESPANOLA DE CARDIOLOGIA, 2019, 72 (09) :775-775
[5]   Intracardiac echocardiography to enable successful edge-to-edge transcatheter tricuspid valve repair in patients with insufficient TEE quality [J].
Curio, Jonathan ;
Abulgasim, Kamal ;
Kasner, Mario ;
Rroku, Andi ;
Lauten, Alexander ;
Lendlein, Andreas ;
Landmesser, Ulf ;
Reinthaler, Markus .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 76 (02) :199-210
[6]   Transcatheter Tricuspid Repair With the Use of 4-Dimensional Intracardiac Echocardiography [J].
Davidson, Charles J. J. ;
Abramson, Sandra ;
Smith, Robert L. L. ;
Kodali, Susheel K. K. ;
Kipperman, Robert M. M. ;
Eleid, Mackram F. F. ;
Reisman, Mark K. ;
Whisenant, Brian K. ;
Puthumana, Jyothy ;
Fowler, Dale ;
Grayburn, Paul A. A. ;
Hahn, Rebecca T. T. ;
Koulogiannis, Konstantinos ;
Pislaru, Sorin V. ;
Zwink, Todd ;
Minder, Michael ;
Deuschl, Florian ;
Feldman, Ted ;
Gray, William A. ;
Lim, D. Scott .
JACC-CARDIOVASCULAR IMAGING, 2022, 15 (03) :533-538
[7]   Intraprocedural Imaging of Transcatheter Tricuspid Valve Interventions [J].
Hahn, Rebecca T. ;
Nabauer, Michael ;
Zuber, Michel ;
Nazif, Tamim M. ;
Hausleiter, Joerg ;
Taramasso, Maurizio ;
Pozzoli, Alberto ;
George, Isaac ;
Kodali, Susheel ;
Bapat, Vinayak ;
Maisano, Francesco .
JACC-CARDIOVASCULAR IMAGING, 2019, 12 (03) :532-553
[8]   Characteristics and treatment strategies for severe tricuspid regurgitation [J].
Ingraham, Brenden S. ;
Pislaru, Sorin V. ;
Nkomo, Vuyisile T. ;
Nishimura, Rick A. ;
Stulak, John M. ;
Dearani, Joseph A. ;
Rihal, Charanjit S. ;
Eleid, Mackram F. .
HEART, 2019, 105 (16) :1244-1250
[9]   Feasibility Study of the Transcatheter Valve Repair System for Severe Tricuspid Regurgitation [J].
Kodali, Susheel ;
Hahn, Rebecca T. ;
Eleid, Mackram F. ;
Kipperman, Robert ;
Smith, Robert ;
Lim, D. Scott ;
Gray, William A. ;
Narang, Akhil ;
Pislaru, Sorin V. ;
Koulogiannis, Konstantinos ;
Grayburn, Paul ;
Fowler, Dale ;
Hawthorne, Katie ;
Dahou, Abdellaziz ;
Deo, Shekhar H. ;
Vandrangi, Prashanthi ;
Deuschl, Florian ;
Mack, Michael J. ;
Leon, Martin B. ;
Feldman, Ted ;
Davidson, Charles J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (04) :345-356
[10]   Intracardiac Echocardiography From the Left Atrium for Procedural Guidance of Transcatheter Left Atrial Appendage Occlusion [J].
Korsholm, Kasper ;
Jensen, Jesper Moller ;
Nielsen-Kudsk, Jens Erik .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (21) :2199-2206