Development and Validation of a Novel RP-HPLC Analytical Method for Sitagliptin Determination in Human Plasma

被引:2
作者
Pamu, Sagar [1 ,2 ]
Patyar, Sazal [1 ]
Thakkalapally, Lakshmi [2 ]
机构
[1] Lovely Profess Univ, Sch Pharmaceut Sci, Jalandhar, Punjab, India
[2] Guru Nanak Inst Tech Campus, Sch Pharm, Ibrahimpatnam, Telangana, India
关键词
RP-HPLC; sitagliptin; method development; validation; human plasma; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIPEPTIDYL-PEPTIDASE-4; INHIBITOR; DPP-4; PHARMACOKINETICS;
D O I
10.9734/JPRI/2021/v33i42B32430
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Different bio-analytic methods have been developed for determining drug concentration in plasma, but methods for sitagliptin determination are still very rare. In this study, RP-HPLC based method has been developed for assessing sitagliptin concentration in plasma. Aim: To develop and validate RP-HPLC based analytical method for estimating sitagliptin in human plasma for pharmacokinetic applications. Methods: In the present study, the mobile phase composed of acetonitrile: 0.5% triethanolamine (20:80) with pH 6.5 has been utilized. Samples of plasma containing sitagliptin and internal standard (IS)-rosiglitazone were extracted with dichloromethane:diethyl ether (4:6; v/v) at pH 7.4. The rate of flow was 1 ml/min. The retention time was about 5,232 and 6,903 minutes respectively for sitagliptin and rosiglitazone. Results: At concentrations of 100-3200 ng/ml in plasma, calibration curves of sitagliptin were linear. The inter- and intra-day precision and accuracy ranged in between 93.56-98.56% and 1.09-4.55% respectively. For specificity, the study findings showed no co-eluting peaks occurring with IS drug (rosiglitazone) and confirmed that no percentage of interferences at analyte (sitagliptin) retention in presence of rosiglitazone. The sitagliptin recovery was 96.442%. Chromatographic separations were performed on HI Qsil C-18 HS column (250mm x 4.6mm x 5 mu m). The stability of stock solutions of sitagliptin and IS at room temperature was 98.06% and 100.79% respectively while under refrigerated conditions stability was 98.19% and 96.59% respectively. Freeze-thaw stability for sitagliptin was performed with low & high QC and shown as 98.26% for and 97.45% respectively. The limits of detection and quantification were 8.592 ng/ml and 28.641 ng/ml respectively. Conclusion: A simple, sensitive and accurate method was developed for bio analytical estimation of sitagliptin in human plasma using liquid-liquid extraction technique. The validation results of linearity, accuracy, precision, stability, selectivity, ruggedness, LOD and LOQ were good under acceptable limit and can be applied for pharmacokinetic studies.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 18 条
[1]  
Anil D, 2012, J PHARM PHARM SCI, V4, P691
[2]  
[Anonymous], 2005, INT C HARM TECHN REQ
[3]  
Arun MK, 2012, AM J PHARM TECH RES, V2, P805
[4]  
Bala Sekaran C, 2010, INT J PHARM PHARM SC, P138
[5]   Disposition of the dipeptidyl peptidase 4 inhibitor sitagliptin in rats and dogs [J].
Beconi, Maria G. ;
Reed, James R. ;
Teffera, Yohannes ;
Xia, Yuan-Qing ;
Kochansky, Christopher J. ;
Liu, David Q. ;
Xu, Shiyao ;
Elmore, Charles S. ;
Ciccotto, Suzanne ;
Hora, Donald F. ;
Stearns, Ralph A. ;
Vincent, Stella H. .
DRUG METABOLISM AND DISPOSITION, 2007, 35 (04) :525-532
[6]  
Chamberlain J., 1985, Analysis of Drugs in Biological Fluids
[7]   Simultaneous determination of ranitidine and metronidazole in human plasma using high performance liquid chromatography with diode array detection [J].
do Nascimento, TG ;
Oliveira, EDJ ;
Macêdo, RO .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (04) :777-783
[8]  
Dolan J.W., 1989, TROUBLESHOOTING LC S
[9]   Review of sitagliptin phosphate: a novel treatment for type 2 diabetes [J].
Gallwitz, Baptist .
VASCULAR HEALTH AND RISK MANAGEMENT, 2007, 3 (02) :203-210
[10]   Validation of a high-performance liquid chromatography method for tramadol and o-desmethyltramadol in human plasma using solid-phase extraction [J].
Gan, SH ;
Ismail, R .
JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (02) :325-335