Development of new biodegradable hydrogel glue for preventing alveolar air leakage

被引:44
作者
Araki, Masato
Tao, Hiroyuki
Nakajima, Naoki
Sugai, Hajime
Sato, Toshihiko
Hyon, Suong-Hyu
Nagayasu, Takeshi
Nakamura, Tatsuo
机构
[1] Kyoto Univ, Inst Frontier Med Sci, Dept Bioartificial Organs, Kyoto, Japan
[2] Kyoto Univ, Inst Frontier Med Sci, Dept Med Simulat Engn, Kyoto, Japan
[3] Nagasaki Univ, Grad Sch Biomed Sci, Dept Translat Med Sci, Div Surg Oncol, Nagasaki 852, Japan
关键词
D O I
10.1016/j.jtcvs.2007.07.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Air leakage is a frequent complication during lung surgery. A new hydrogel glue was created by mixing aldehyded dextran and epsilon-poly(l-lysine), and its feasibility as a surgical sealant was evaluated in comparison with that of conventional fibrin glue. Methods: Bursting pressure after application of each glue to 30 X 30-mm pleuro-parenchymal defects was evaluated in two groups of 14 beagle dogs. Biodegradability and histotoxicity of the glues were evaluated in another 6 dogs with 15-mm circular pleuroparenchymal defects. Adhesions, infections, and histologic changes were observed on scheduled days for 6 months. Results: The mean bursting pressure after application was 38.4 +/- 4.6 cm H2O for the new glue and 32.1 +/- 4.5 cm H2O for fibrin glue (P = .02), the former providing more effective sealing of pulmonary air leakage than the latter. Macroscopically, no adhesions or infections were observed in areas of glue application. About 90% of the new glue degraded within 3 months, but complete disappearance was not observed by 6 months. On the other hand, the fibrin glue was replaced by white pleural tissue at 4 weeks. Histologically, the new glue was covered by one layer of mesothelial cells at 2 weeks and completely covered by thick fibrous tissue at 4 weeks. Inflammatory reaction was minimal around the residual glue after 3 months. Although the new glue degraded more slowly than did the fibrin glue, the biocompatibility of the new glue was sufficient for clinical use. Conclusion: Our new hydrogel glue demonstrates a strong sealing effect, with good biocompatibility, and has potential usefulness as an adhesive in lung surgery.
引用
收藏
页码:1241 / 1248
页数:8
相关论文
共 21 条
[1]   Prospective randomized study evaluating a biodegradable polymeric sealant for sealing intraoperative air leaks that occur during pulmonary resection [J].
Allen, MS ;
Wood, DE ;
Hawkinson, RW ;
Harpole, DH ;
McKenna, RJ ;
Walsh, GL ;
Vallieres, E ;
Miller, DL ;
Nichols, FC ;
Smythe, WR ;
Davis, RD .
ANNALS OF THORACIC SURGERY, 2004, 77 (05) :1792-1801
[2]   Creation of a uniform pleural defect model for the study of lung sealants [J].
Araki, Masato ;
Tao, Hiroyuki ;
Sato, Toshihiko ;
Nakajima, Naoki ;
Sugai, Hajime ;
Hyon, Suong-Hyu ;
Nagayasu, Takeshi ;
Nakamura, Tatsuo .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (01) :145-151
[3]   The effect of autologous fibrin sealant (Vivostat®) on morbidity after pulmonary lobectomy:: a prospective randomised, blinded study [J].
Belboul, A ;
Dernevik, L ;
Aljassim, O ;
Skrbic, B ;
Radberg, G ;
Roberts, D .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (06) :1187-1191
[4]   Experimental study on the in vivo behaviour of a new collagen glue in lung surgery [J].
Feito, BA ;
Rath, AM ;
Longchampt, E ;
Azorin, J .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (01) :8-13
[5]   EFFECT OF ROUTINE FIBRIN GLUE USE ON THE DURATION OF AIR LEAKS AFTER LOBECTOMY [J].
FLEISHER, AG ;
EVANS, KG ;
NELEMS, B ;
FINLEY, RJ .
ANNALS OF THORACIC SURGERY, 1990, 49 (01) :133-134
[6]   Experimental use of an albumin-glutaraldehyde tissue adhesive for sealing pulmonary parenchyma and bronchial anastomoses [J].
Herget, GW ;
Kassa, M ;
Riede, UN ;
Lu, Y ;
Brethner, L ;
Hasse, J .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (01) :4-9
[7]   The seating effect of fibrin glue against alveolar air leakage evaluated up to 48 h; comparison between different methods of application [J].
Kawamura, M ;
Gika, M ;
Izumi, Y ;
Horinouchi, H ;
Shinya, N ;
Mukai, M ;
Kobayashi, K .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) :39-42
[8]   Frequency of transmission of human parvovirus B19 infection by fibrin sealant used during thoracic surgery [J].
Kawamura, M ;
Sawafuji, M ;
Watanabe, M ;
Horinouchi, H ;
Kobayashi, K .
ANNALS OF THORACIC SURGERY, 2002, 73 (04) :1098-1100
[9]   Prevention of air leakage by spraying Vivostat fibrin sealant after lung resection in pigs [J].
Kjaergard, HK ;
Pedersen, JH ;
Krasnik, M ;
Weis-Fogh, US ;
Fleron, H ;
Griffin, HE .
CHEST, 2000, 117 (04) :1124-1127
[10]   In vivo evaluation of a new sealant material on a rat lung air leak model [J].
Kobayashi, H ;
Sekine, T ;
Nakamura, T ;
Shimizu, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (06) :658-665