An Adaptive Early Fault Detection Model of Induced Draft Fans Based on Multivariate State Estimation Technique

被引:9
作者
Guo, Ruijun [1 ]
Zhang, Guobin [1 ]
Zhang, Qian [1 ]
Zhou, Lei [1 ]
Yu, Haicun [1 ]
Lei, Meng [2 ]
Lv, You [2 ,3 ]
机构
[1] Inner Mongolia Power Res Inst, Hohhot 010020, Peoples R China
[2] North China Elect Power Univ, Sch Control & Comp Engn, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, Key Lab Power Stn Energy Transfer Convers & Syst, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
fault detection; induced draft fan; multivariate state estimation technique; model update; coal-fired power plant; REMAINING LIFE; DIAGNOSIS; PREDICTION; PCA;
D O I
10.3390/en14164787
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The induced draft (ID) fan is an important piece of auxiliary equipment in coal-fired power plants. Early fault detection of the ID fan can provide predictive maintenance and reduce unscheduled shutdowns, thus improving the reliability of the power generation. In this study, an adaptive model was developed to achieve the early fault detection of ID fans. First, a non-parametric monitoring model was constructed to describe the normal operating characteristics with the multivariate state estimation technique (MSET). A similarity index representing operation status was defined according to the prediction deviations to produce warnings of early faults. To deal with the model accuracy degradation because of variant condition operation of the ID fan, an adaptive strategy was proposed by using the samples with a high data quality index (DQI) to manage the memory matrix and update the MSET model, thereby improving the fault detection results. The proposed method was applied to a 300 MW coal-fired power plant to achieve the early fault detection of an ID fan. In addition, fault detection by using the model without an update was also compared. Results show that the update strategy can greatly improve the MSET model accuracy when predicting normal operations of the ID fan; accordingly, the fault can be detected more than 4 h earlier by using the strategy with the adaptive update when compared to the model without an update.
引用
收藏
页数:18
相关论文
共 42 条
[21]   Adaptive Information Sharing with Ontological Relevance Computation for Decentralized Self-Organization Systems [J].
Liu, Wei ;
Ran, Weizhi ;
Nantogma, Sulemana ;
Xu, Yang .
ENTROPY, 2021, 23 (03)
[22]   Just-in-Time Kernel Learning with Adaptive Parameter Selection for Soft Sensor Modeling of Batch Processes [J].
Liu, Yi ;
Gao, Zengliang ;
Li, Ping ;
Wang, Haiqing .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (11) :4313-4327
[23]   Condition Monitoring of Industrial Equipment Based on Multi-Variables State Estimate Technique [J].
Long, Dongteng ;
Zheng, Heng ;
Hong, Feng .
APPLIED SCIENCES-BASEL, 2020, 10 (16)
[24]   An early fault detection method for induced draft fans based on MSET with informative memory matrix selection [J].
Lv, You ;
Fang, Fang ;
Yang, Tingting ;
Romero, Carlos E. .
ISA TRANSACTIONS, 2020, 102 :325-334
[25]   Adaptive selective catalytic reduction model development using typical operating data in coal-fired power plants [J].
Lv, You ;
Lv, Xuguang ;
Fang, Fang ;
Yang, Tingting ;
Romero, Carlos E. .
ENERGY, 2020, 192
[26]   Wind Turbine Fault Detection through Principal Component Analysis and Statistical Hypothesis Testing [J].
Pozo, Francesc ;
Vidal, Yolanda .
ENERGIES, 2016, 9 (01)
[27]   Improved Hierarchical Adaptive Deep Belief Network for Bearing Fault Diagnosis [J].
Shen, Changqing ;
Xie, Jiaqi ;
Wang, Dong ;
Jiang, Xingxing ;
Shi, Juanjuan ;
Zhu, Zhongkui .
APPLIED SCIENCES-BASEL, 2019, 9 (16)
[28]   Fault detection using multiscale PCA-based moving window GLRT [J].
Sheriff, M. Ziyan ;
Mansouri, Majdi ;
Karim, M. Nazmul ;
Nounou, Hazem ;
Nounou, Mohamed .
JOURNAL OF PROCESS CONTROL, 2017, 54 :47-64
[29]   Research on a Nonlinear Dynamic Incipient Fault Detection Method for Rolling Bearings [J].
Shi, Huaitao ;
Guo, Jin ;
Bai, Xiaotian ;
Guo, Lei ;
Liu, Zhenpeng ;
Sun, Jie .
APPLIED SCIENCES-BASEL, 2020, 10 (07)
[30]   On-Line Diagnosis and Fault State Classification Method of Photovoltaic Plant [J].
Shin, Jun-Hyun ;
Kim, Jin-O .
ENERGIES, 2020, 13 (17)