An Adaptive Early Fault Detection Model of Induced Draft Fans Based on Multivariate State Estimation Technique

被引:9
作者
Guo, Ruijun [1 ]
Zhang, Guobin [1 ]
Zhang, Qian [1 ]
Zhou, Lei [1 ]
Yu, Haicun [1 ]
Lei, Meng [2 ]
Lv, You [2 ,3 ]
机构
[1] Inner Mongolia Power Res Inst, Hohhot 010020, Peoples R China
[2] North China Elect Power Univ, Sch Control & Comp Engn, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, Key Lab Power Stn Energy Transfer Convers & Syst, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
fault detection; induced draft fan; multivariate state estimation technique; model update; coal-fired power plant; REMAINING LIFE; DIAGNOSIS; PREDICTION; PCA;
D O I
10.3390/en14164787
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The induced draft (ID) fan is an important piece of auxiliary equipment in coal-fired power plants. Early fault detection of the ID fan can provide predictive maintenance and reduce unscheduled shutdowns, thus improving the reliability of the power generation. In this study, an adaptive model was developed to achieve the early fault detection of ID fans. First, a non-parametric monitoring model was constructed to describe the normal operating characteristics with the multivariate state estimation technique (MSET). A similarity index representing operation status was defined according to the prediction deviations to produce warnings of early faults. To deal with the model accuracy degradation because of variant condition operation of the ID fan, an adaptive strategy was proposed by using the samples with a high data quality index (DQI) to manage the memory matrix and update the MSET model, thereby improving the fault detection results. The proposed method was applied to a 300 MW coal-fired power plant to achieve the early fault detection of an ID fan. In addition, fault detection by using the model without an update was also compared. Results show that the update strategy can greatly improve the MSET model accuracy when predicting normal operations of the ID fan; accordingly, the fault can be detected more than 4 h earlier by using the strategy with the adaptive update when compared to the model without an update.
引用
收藏
页数:18
相关论文
共 42 条
[11]  
Gross K.C., 1997, P 9 INT C INT SYST A, P212
[12]   Wind Turbine Generator Condition-Monitoring Using Temperature Trend Analysis [J].
Guo, Peng ;
Infield, David ;
Yang, Xiyun .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2012, 3 (01) :124-133
[13]   Wind Turbine Gearbox Condition Monitoring with AAKR and Moving Window Statistic Methods [J].
Guo, Peng ;
Bai, Nan .
ENERGIES, 2011, 4 (11) :2077-2093
[14]   Mechanical Fault Diagnosis of a DC Motor Utilizing United Variational Mode Decomposition, SampEn, and Random Forest-SPRINT Algorithm Classifiers [J].
Guo, Zijian ;
Liu, Mingliang ;
Qin, Huabin ;
Li, Bing .
ENTROPY, 2019, 21 (05)
[15]   Sequential Method with Incremental Analysis Update to Retrieve Leaf Area Index from Time Series MODIS Reflectance Data [J].
Jiang, Jingyi ;
Xiao, Zhiqiang ;
Wang, Jindi ;
Song, Jinling .
REMOTE SENSING, 2014, 6 (10) :9194-9212
[16]  
Jinfeng Du, 2016, Case Studies in Engineering Failure Analysis, V5-6, P51, DOI 10.1016/j.csefa.2016.02.002
[17]   Review of adaptation mechanisms for data-driven soft sensors [J].
Kadlec, Petr ;
Grbic, Ratko ;
Gabrys, Bogdan .
COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (01) :1-24
[18]   Adaptive database management based on the database monitoring index for long-term use of adaptive soft sensors [J].
Kaneko, Hiromasa ;
Funatsu, Kimito .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 146 :179-185
[19]   Development and Validation of a Data-Driven Fault Detection and Diagnosis System for Chillers Using Machine Learning Algorithms [J].
Kim, Icksung ;
Kim, Woohyun .
ENERGIES, 2021, 14 (07)
[20]   Early Fault Detection of Gas Turbine Hot Components Based on Exhaust Gas Temperature Profile Continuous Distribution Estimation [J].
Liu, Jinfu ;
Bai, Mingliang ;
Long, Zhenhua ;
Liu, Jiao ;
Ma, Yujia ;
Yu, Daren .
ENERGIES, 2020, 13 (22)