Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations

被引:14
|
作者
Howard, Leigh A. [1 ]
Lidbury, Jonathan A. [1 ]
Jeffe, Nicholas [1 ]
Washburn, Shannon E. [2 ]
Patterson, Carly A. [2 ]
机构
[1] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Small Anim Clin Sci, College Stn, TX 77843 USA
[2] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Vet Physiol & Pharmacol, College Stn, TX 77843 USA
关键词
dog; FreeStyle Libre; hypoglycemia; interstitial glucose; OF-CARE GLUCOMETER; ACCURACY; METERS; PLASMA; CANINE; CATS;
D O I
10.1111/jvim.16273
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background A flash glucose monitoring system (FGMS; FreeStyle Libre) is useful for monitoring hypoglycemic dogs with diabetes. Objective To assess the utility of this FGMS in dogs with induced hypoglycemia and rapid fluctuations in blood glucose (BG) concentrations. Animals Twenty-four apparently healthy research (n = 10) and teaching (n = 14) dogs. Methods Prospective, observational study performed in tandem with a teaching laboratory. Regular insulin was administered to dogs and resulting hypoglycemia was corrected. Before insulin administration and every 10 minutes over a 90-minute period, serial measurements of interstitial glucose (IG) with FGMS and BG with a portable blood glucose meter (PBGM) and clinical chemistry analyzer concentrations were made. Portable blood glucose meter and FGMS readings were compared to that of the clinical chemistry analyzer. Analytical and clinical accuracy were assessed using ISO 15197:2013 criteria, including Parkes error grid analysis. Results The proportions of readings in the low BG range (BG <100 mg/dL) for which the test method measurement was within +/- 15 mg/dL of the reference BG for the PBGM and FGMS were 81.7% (161/197) and 39.1% (72/184), respectively. The proportions of readings for the PBGM and FGMS, which were not likely to affect clinical outcome according to Parkes error grid analysis, were 97.9% (233/238) and 80.1% (177/221), respectively. Conclusions and Clinical Importance In this model, there was limited agreement between the FGMS and reference standard BG measurements. The FGMS (measuring IG concentrations) was compared to peripheral BG concentrations, not brain-tissue glucose concentrations, and failed to reliably detect hypoglycemia.
引用
收藏
页码:2628 / 2635
页数:8
相关论文
共 50 条
  • [31] FLASH GLUCOSE MONITORING (FGM)
    Szewczyk, Alicja
    Tobiasz-Kalkun, Natasza
    Stefanowicz-Bielska, Anna
    Kobos, Ewa
    Mtynarczuk, Miroslawa
    Kapusciok, Justyna
    Michalowska, Jolanta
    PIELEGNIARSTWO XXI WIEKU-NURSING IN THE 21 CENTURY, 2020, 19 (03): : 189 - 190
  • [32] Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus
    Knies, Marieke
    Teske, Erik
    Kooistra, Hans
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2022, 24 (08) : E223 - E231
  • [33] Comparison of an Intermittently Scanned (Flash) Continuous Glucose Monitoring System to Standard Self-Monitoring of Capillary Blood Glucose in Gestational Diabetes Mellitus
    Hussain, Farrah N.
    Raymond, Samantha
    Feldman, Kristina M.
    Scarpelli-Shchur, Sophia
    Strauss, Tirtza S.
    Al-Ibraheemi, Zainab
    Brustman, Lois
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (11) : 1149 - 1157
  • [34] Evaluation of the performance of a new OptiScanner™ 5000 system for an intermittent glucose monitoring
    Barassi, Alessandra
    Umbrello, Michele
    Ghilardi, Francesca
    Damele, Clara Anna Linda
    Massaccesi, Luca
    Iapichino, Gaetano
    d'Eril, Gian Vico Melzi
    CLINICA CHIMICA ACTA, 2015, 438 : 252 - 254
  • [35] Evaluation of continuous flash glucose monitoring in a pediatric ICU setting
    Kotzapanagiotou, Eirini
    Tsotridou, Eleni
    Volakli, Eleni
    Dimitriadou, Meropi
    Chochliourou, Elpis
    Kalamitsou, Serafeia
    Kotzapanagiotou, Fani
    Sdougka, Maria
    Christoforidis, Athanasios
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (04) : 843 - 852
  • [36] Evaluation of a continuous glucose monitoring system in neonatal foals
    Wong, David
    Malik, Caitlin
    Dembek, Katarzyna
    Estell, Krista
    Marchitello, Megan
    Wilson, Katie
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (04) : 1995 - 2001
  • [37] Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System
    Ji, Linong
    Guo, Lixin
    Zhang, Junqing
    Li, Yufeng
    Chen, Zhiyan
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 208 - 213
  • [38] Evaluation of newly developed veterinary portable blood glucose meter with hematocrit correction in dogs and cats
    Mori, Akihiro
    Oda, Hitomi
    Onozawa, Eri
    Shono, Saori
    Sako, Toshinori
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2017, 79 (10) : 1690 - 1693
  • [39] Evaluation of four portable blood glucose meters in diabetic and non-diabetic dogs and cats
    Kang, Min-Hee
    Kim, Do-Hyung
    Jeong, In-Seong
    Choi, Gab-Chol
    Park, Hee-Myung
    VETERINARY QUARTERLY, 2016, 36 (01) : 2 - 9
  • [40] National Consensus in the Use of the Flash Glucose Monitoring System in Portugal
    Cardoso, Helena
    Carvalho, Davide
    Pape, Estevao
    Carrilho, Francisco
    Raposo, Joao Filipe
    Melo, Miguel
    Carvalho, Ema
    Duarte, Rui
    REVISTA PORTUGUESA DE ENDOCRINOLOGIA DIABETES E METABOLISMO, 2019, 14 (01) : 74 - 81