Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations

被引:14
|
作者
Howard, Leigh A. [1 ]
Lidbury, Jonathan A. [1 ]
Jeffe, Nicholas [1 ]
Washburn, Shannon E. [2 ]
Patterson, Carly A. [2 ]
机构
[1] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Small Anim Clin Sci, College Stn, TX 77843 USA
[2] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Vet Physiol & Pharmacol, College Stn, TX 77843 USA
关键词
dog; FreeStyle Libre; hypoglycemia; interstitial glucose; OF-CARE GLUCOMETER; ACCURACY; METERS; PLASMA; CANINE; CATS;
D O I
10.1111/jvim.16273
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background A flash glucose monitoring system (FGMS; FreeStyle Libre) is useful for monitoring hypoglycemic dogs with diabetes. Objective To assess the utility of this FGMS in dogs with induced hypoglycemia and rapid fluctuations in blood glucose (BG) concentrations. Animals Twenty-four apparently healthy research (n = 10) and teaching (n = 14) dogs. Methods Prospective, observational study performed in tandem with a teaching laboratory. Regular insulin was administered to dogs and resulting hypoglycemia was corrected. Before insulin administration and every 10 minutes over a 90-minute period, serial measurements of interstitial glucose (IG) with FGMS and BG with a portable blood glucose meter (PBGM) and clinical chemistry analyzer concentrations were made. Portable blood glucose meter and FGMS readings were compared to that of the clinical chemistry analyzer. Analytical and clinical accuracy were assessed using ISO 15197:2013 criteria, including Parkes error grid analysis. Results The proportions of readings in the low BG range (BG <100 mg/dL) for which the test method measurement was within +/- 15 mg/dL of the reference BG for the PBGM and FGMS were 81.7% (161/197) and 39.1% (72/184), respectively. The proportions of readings for the PBGM and FGMS, which were not likely to affect clinical outcome according to Parkes error grid analysis, were 97.9% (233/238) and 80.1% (177/221), respectively. Conclusions and Clinical Importance In this model, there was limited agreement between the FGMS and reference standard BG measurements. The FGMS (measuring IG concentrations) was compared to peripheral BG concentrations, not brain-tissue glucose concentrations, and failed to reliably detect hypoglycemia.
引用
收藏
页码:2628 / 2635
页数:8
相关论文
共 50 条
  • [1] Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus
    Del Baldo, Francesca
    Canton, Claudia
    Testa, Silvia
    Swales, Harry
    Drudi, Ignazio
    Golinelli, Stefania
    Fracassi, Federico
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (06) : 2296 - 2305
  • [2] Assessment of postprandial hyperglycemia and circadian fluctuation of glucose concentrations in diabetic dogs using a flash glucose monitoring system
    Shea, Emily K.
    Hess, Rebecka S.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (02) : 843 - 852
  • [3] Flash glucose monitoring system - an alternative for glucose monitoring in animals
    Voigt, Lisa
    KLEINTIERPRAXIS, 2019, 64 (06): : 348 - 357
  • [4] Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Malerba, Eleonora
    Cattani, Chiara
    Del Baldo, Francesca
    Carotenuto, Gaia
    Corradini, Sara
    Golinelli, Stefania
    Drudi, Ignazio
    Fracassi, Federico
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (01) : 83 - 91
  • [5] Evaluation of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Silva, D. D.
    Cecci, G. R. M.
    Biz, G.
    Chiaro, F. N.
    Zanutto, M. S.
    DOMESTIC ANIMAL ENDOCRINOLOGY, 2021, 74
  • [6] Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs
    Corradini, S.
    Pilosio, B.
    Dondi, F.
    Linari, G.
    Testa, S.
    Brugnoli, F.
    Gianella, P.
    Pietra, M.
    Fracassi, F.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2016, 30 (04): : 983 - 988
  • [7] Accuracy of a flash glucose monitoring system in healthy dogs during isoflurane anesthesia
    Pollack, Elizabeth A.
    Cromwell, Lauren N.
    Zhao, Qianqian
    Sage, Adrianna M.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2025, 86 (02)
  • [8] Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
    Del Baldo, Francesca
    Fracassi, Federico
    Pires, Jully
    Tardo, Antonio Maria
    Malerba, Eleonora
    Manassero, Elisa
    Gilor, Chen
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (03) : 1279 - 1287
  • [9] Complications associated with a flash glucose monitoring system in diabetic dogs
    Campbell, Carson
    Shoelson, Adam
    Mahony, Orla
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2023, 87 (04): : 260 - 264
  • [10] Flash glucose monitoring in type 1 diabetes: A comparison with self-monitoring blood glucose
    Babaya, Naru
    Noso, Shinsuke
    Hiromine, Yoshihisa
    Taketomo, Yasunori
    Niwano, Fumimaru
    Yoshida, Sawa
    Yasutake, Sara
    Kawabata, Yumiko
    Ikegami, Hiroshi
    JOURNAL OF DIABETES INVESTIGATION, 2020, 11 (05) : 1222 - 1229