24-Month Clinical Performance of a Universal Adhesive on Non-Carious Cervical Lesions: Self-Etch and Etch-and Rinse Techniques

被引:4
作者
Cruz, Joana [1 ]
Silva, Ana Luisa [1 ]
Eira, Raquel [1 ]
Coito, Catarina [1 ]
Sousa, Bernardo Romao [1 ]
Lopes, Maria Manuela [2 ]
Cavalheiro, Alexandre [1 ]
机构
[1] Univ Lisbon, Fac Dent Med, Dept Operat Dent, Lisbon, Portugal
[2] Univ Lisbon, Fac Dent Med, Rua Prof Teresa Ambrosio,Cidade Univ, P-1600277 Lisbon, Portugal
关键词
clinical trial; self-etch mode; etch-and-rinse mode; universal adhesive; application modes; non-carious cervical lesions; POLYACID-MODIFIED RESIN; COMPOSITE RESTORATIONS; BOND STRENGTH; GLASS-IONOMER; SINGLE-STEP; ENAMEL; DENTIN; ADAPTATION; IMMEDIATE; CRITERIA;
D O I
10.3290/j.jad.b2000173
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the 24-month clinical performance of Adhese Universal (ADH) (Ivoclar Vivadent) using two different application modes (etch-and-rinse vs self-etch) when restoring non-carious cervical lesions. Materials and Methods: Twenty-six patients participated in this study. A total of 117 non-carious cervical lesion restorations (N = 117) were assigned to two groups: 1) ADH in the etch-and-rinse mode (n = 59) and 2) ADH in the self-etch mode (n = 58). The same resin composite (Tetric EvoCeram, Ivoclar Vivadent) was used for all restorations. The restorations were evaluated at baseline and at 24 months using the World Dental Federation (FDI) criteria. The results were analyzed statistically using the McNemar test (a = 0.05) and a generalized estimating equation. Results: In self-etch mode, significant differences were found for marginal coloring (p = 0.002), marginal adaptation (p = 0.031), and hypersensitivity (p = 0.031) between baseline and the end of the 24-month period. In the etch-and-rinse mode, significant differences were found for marginal coloring (p = 0.004), fractures/retention (p = 0.002), marginal adaptation (p = 0.002), and hypersensitivity (p = 0.000). Significant differences were also detected between groups at 24 months for fractures/retention (p = 0.001). At 24 months, 10 restorations of the etch-and-rinse group were lost and 2 restorations of the self-etch group were lost. Conclusion: In terms of fractures and retention criteria, this universal adhesive obtained better results when applied in self-etch mode than in etch-and-rinse mode.
引用
收藏
页码:379 / 387
页数:9
相关论文
共 61 条
[1]  
American Dental Association, 2001, ADA ACC PROGR GUID D
[2]   Immediate bonding properties of universal adhesives to dentine [J].
Angel Munoz, Miguel ;
Luque, Issis ;
Hass, Viviane ;
Reis, Alessandra ;
Loguercio, Alessandro Dourado ;
Campanha Bombarda, Nara Hellen .
JOURNAL OF DENTISTRY, 2013, 41 (05) :404-411
[3]   Thirty-six-month clinical evaluation of different adhesive strategies of a universal adhesive [J].
Atalay, Cansu ;
Ozgunaltay, Gul ;
Yazici, Ayse Ruya .
CLINICAL ORAL INVESTIGATIONS, 2020, 24 (04) :1569-1578
[4]  
Baratieri LN, 2003, OPER DENT, V28, P482
[5]  
Bayne S C, 1991, Am J Dent, V4, P247
[6]   10-MDP Based Dental Adhesives: Adhesive Interface Characterization and Adhesive StabilityA Systematic Review [J].
Carrilho, Eunice ;
Cardoso, Miguel ;
Ferreira, Manuel Marques ;
Marto, Carlos Miguel ;
Paula, Anabela ;
Coelho, Ana Sofia .
MATERIALS, 2019, 12 (05)
[7]  
Cruz J, 2019, AM J DENT, V32, P174
[8]  
Cvar JF, 2005, CLIN ORAL INVEST, V9, P215, DOI 10.1007/s00784-005-0018-z
[9]   Marginal and internal adaptation of class II restorations after immediate or delayed composite placement [J].
Dietschi, D ;
Monasevic, M ;
Krejci, I ;
Davidson, C .
JOURNAL OF DENTISTRY, 2002, 30 (5-6) :259-269
[10]   G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences [J].
Faul, Franz ;
Erdfelder, Edgar ;
Lang, Albert-Georg ;
Buchner, Axel .
BEHAVIOR RESEARCH METHODS, 2007, 39 (02) :175-191