Bronchial responsiveness to ultrasonic ''fog'' in occupational asthma due to low molecular weight chemicals

被引:2
作者
Dellabianca, A
Omodeo, P
Colli, MC
Bianchi, P
Scibilia, J
Moscato, G
机构
[1] UNIV PAVIA,SPECIALIZAT SCH ALLERGOL & CLIN IMMUNOL,PAVIA,ITALY
[2] UNIV PAVIA,SPECIALIZAT SCH OCCUPAT MED,PAVIA,ITALY
[3] IRCCS,MED CTR PAVIA,SALVATORE MAUGERI FDN,OCCUPAT & REHABIL CLIN,DEPT ALLERGY & CLIN IMMUNO,PAVIA,ITALY
关键词
D O I
10.1016/S1081-1206(10)63336-4
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: In a previous work we have demonstrated that the use of an indirect stimulus such as ultrasonically nebulized distilled water (UNDW, ''fog'') challenge, in addition to methacholine, in the assessment of occupational asthma due to TDI improves our ability in detecting sensitized subjects. Objective: In the present study we aimed to determine the validity of ''fog'' in the assessment of occupational asthma induced by various low molecular weight substances. Methods: Fourty subjects exposed to low molecular weight substances with work-related respiratory symptoms underwent methacholine, UNDW and specific bronchial challenge tests. Diagnosis of occupational asthma was made in 20 of 40 patients who developed bronchoconstrictive responses to the specific challenges (reactors). Sensitivity and specificity of UNDW alone, of methacholine alone, and of the combination of the two tests were determined at two different cutpoints of PD,,FEV, of methacholine, with the results of the specific challenge as the ''gold standard.'' Results: Frequency and severity of bronchial hyperresponsiveness both to UNDW and to methacholine were significantly higher in reactors than in nonreactors. Ultrasonically nebulized distilled water had higher specificity (80% versus 60%) but lower sensitivity (65% versus 75% to 90%) than methacholine. As compared with methacholine alone, the combination in series of the two challenges (both challenges positive) substantially improved specificity (85% versus 60%). Conclusions: In conclusion, In the assessment of low molecular weight chemical-induced asthma diagnosed with the specific challenge as the ''gold standard,'' UNDW challenge proves more specific than methacholine for occupational asthma, but it is considerably less sensitive. The combination of the two challenges results in very high sensitivity and high specificity for occupational asthma, therefore, although further investigations are required for the definitive diagnosis, it should be regarded as a useful means to confirm objectively a suggestive history.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 22 条
[1]  
*AM C GOV IND HYG, 1993, AM C GOV IND HYG 199
[2]   OSMOTIC CHALLENGES IN THE ASSESSMENT OF BRONCHIAL HYPERRESPONSIVENESS [J].
ANDERSON, SD ;
SMITH, CM .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (03) :S43-S46
[3]  
Bernstein David I., 1993, P103
[4]   GUIDELINES FOR BRONCHOPROVOCATION ON THE INVESTIGATION OF OCCUPATIONAL ASTHMA - REPORT OF THE SUBCOMMITTEE-ON-BRONCHOPROVOCATION-FOR-OCCUPATIONAL-ASTHMA [J].
CARTIER, A ;
BERNSTEIN, IL ;
BURGE, PS ;
COHN, JR ;
FABBRI, LM ;
HARGREAVE, FE ;
MALO, JL ;
MCKAY, RT ;
SALVAGGIO, JE .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1989, 84 (05) :823-829
[5]  
Chan-Yeung Moira, 1993, P189
[6]   ETIOLOGIC AGENTS IN OCCUPATIONAL ASTHMA [J].
CHANYEUNG, M ;
MALO, JL .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (02) :346-371
[7]   CURRENT CONCEPTS - OCCUPATIONAL ASTHMA [J].
CHANYEUNG, M ;
MALO, JL .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (02) :107-112
[8]   BRONCHIAL REACTIVITY TO INHALED HISTAMINE - METHOD AND CLINICAL SURVEY [J].
COCKCROFT, DW ;
KILLIAN, DN ;
MELLON, JJA ;
HARGREAVE, FE .
CLINICAL ALLERGY, 1977, 7 (03) :235-243
[9]  
HOPP RJ, 1988, ANN ALLERGY, V60, P129
[10]   IS THE CLINICAL HISTORY A SATISFACTORY MEANS OF DIAGNOSING OCCUPATIONAL ASTHMA [J].
MALO, JL ;
GHEZZO, H ;
LARCHEVEQUE, J ;
LAGIER, F ;
PERRIN, B ;
CARTIER, A .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (03) :528-532