MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: Initial experience

被引:114
作者
Orel, SG
Rosen, M
Mies, C
Schnall, MD
机构
[1] Univ Penn, Med Ctr, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Med Ctr, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
关键词
D O I
10.1148/radiol.2381050050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform magnetic resonance (MR) imaging - compatible vacuum-assisted 9-gauge core-needle biopsy of suspicious enhancing breast lesions identified at MR imaging. Materials and Methods: The institutional review board granted exempt status for this HIPAA-compliant study and waived the requirement for informed consent. The MR imaging-guided 9-gauge vacuum-assisted core-needle biopsy findings of 85 lesions in 75 patients aged 31-89 years were retrospectively reviewed. The biopsies were performed as part of the patients' clinical care with a Food and Drug Administration approved biopsy system and not within a research protocol. All included patients had received a diagnosis of malignant, benign, or high-risk ( for cancer) breast tissue at core-needle biopsy and had undergone subsequent surgery or follow-up imaging. MR imaging-guided biopsy results were compared with final histopathologic or follow-up imaging findings. Results: At MR imaging-guided core-needle biopsy, malignancy was identified in 52 (61%) lesions: 35 invasive cancers and 17 ductal carcinoma in situ (DCIS) lesions. Four (24%) of the 17 DCIS lesions were upgraded to invasive cancer at excisional biopsy or mastectomy. A high-risk lesion (ie, atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, or radial scar) was identified in 18 (21%) cases. Two (25%) of eight atypical ductal hyperplasia lesions were upgraded to DCIS at excision. No malignancy was found in the atypical lobular hyperplasia (n = 2), lobular carcinoma in situ (n = 5), or radial scar (n = 3) lesions. Fifteen (18%) lesions were found to be benign lesions of unknown type at excision or mastectomy. For 13 of these 15 lesions, the benign results were concordant with the imaging findings. Both (two of 86, 2%) discordant cases represented false-negative lesions. The remaining 13 benign lesions were validated at excisional biopsy (n = 9) or follow-up imaging (n = 4). Conclusion: Initial experience revealed MR imaging-guided 9-gauge vacuum- assisted core-needle breast biopsy to be a reasonable alternative to MR imaging-guided wire localization of suspicious lesions identified at MR imaging only, on the basis of published information regarding the latter. (c) RSNA, 2005.
引用
收藏
页码:54 / 61
页数:8
相关论文
共 19 条
  • [1] MRI-guided breast biopsy: Clinical experience with 14-gauge stainless steel core biopsy needle
    Chen, XM
    Lehman, CD
    Dee, KE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 1075 - 1080
  • [2] MRL GUIDED BIOPSY OF SUSPECT BREAST-LESIONS WITH A SIMPLE STEREOTAXIC ADD-ON DEVICE FOR SURFACE COILS
    FISCHER, U
    VOSSHENRICH, R
    KEATING, D
    BRUHN, H
    DOLER, W
    OESTMANN, JW
    GRABBE, E
    [J]. RADIOLOGY, 1994, 192 (01) : 272 - 273
  • [3] MR-guided percutaneous excisional and incisional biopsy of breast lesions
    Heywang-Köbrunner, SH
    Heinig, A
    Schaumlöffel, U
    Viehweg, P
    Buehmann, J
    Lampe, D
    Spielmann, RP
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (08) : 1656 - 1665
  • [4] Heywang-Koebrunner SH, 1999, RADIOLOGY, V213P, P289
  • [5] Healthy premenopausal breast parenchyma in dynamic contrast-enhanced MR imaging of the breast: Normal contrast medium enhancement and cyclical-phase dependency
    Kuhl, CK
    Bieling, HB
    Gieseke, J
    Kreft, BP
    Sommer, T
    Lutterbey, G
    Schild, HH
    [J]. RADIOLOGY, 1997, 203 (01) : 137 - 144
  • [6] Interventional breast MR imaging: Clinical use of a stereotactic localization and biopsy device
    Kuhl, CK
    Elevelt, A
    Leutner, CC
    Gieseke, J
    Pakos, E
    Schild, HH
    [J]. RADIOLOGY, 1997, 204 (03) : 667 - 675
  • [7] Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions?
    Kuhl, CK
    Mielcareck, P
    Klaschik, S
    Leutner, C
    Wardelmann, E
    Gieseke, J
    Schild, HH
    [J]. RADIOLOGY, 1999, 211 (01) : 101 - 110
  • [8] MR imaging-guided large-core (14-gauge) needle biopsy of small lesions visible at breast MR imaging alone
    Kuhl, CK
    Morakkabati, N
    Leutner, CC
    Schmiedel, A
    Wardelmann, E
    Schild, HH
    [J]. RADIOLOGY, 2001, 220 (01) : 31 - 39
  • [9] The clinical value of preoperative wire localization of breast lesions by magnetic resonance imaging - a multicenter study
    Lampe, D
    Hefler, L
    Alberich, T
    Sittek, H
    Perlet, C
    Prat, X
    Taourel, P
    Amaya, B
    Koelbl, H
    Heywang-Kobrunner, SH
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2002, 75 (02) : 175 - 179
  • [10] Breast lesions detected with MR imaging: Utility and histopathologic importance of identification with US
    LaTrenta, LR
    Menell, JH
    Morris, EA
    Abramson, AF
    Dershaw, DD
    Liberman, L
    [J]. RADIOLOGY, 2003, 227 (03) : 856 - 861