Performance of a moment resisting beam-column connection for precast concrete construction

被引:32
作者
Baran, Eray [1 ]
Mahamid, Mustafa [2 ]
Baran, Mehmet [3 ]
Kurtoglu, Metin [4 ]
Torra-Bilal, Ines [5 ]
机构
[1] Middle East Tech Univ, Dept Civil Engn, TR-06800 Ankara, Turkey
[2] Univ Illinois, Dept Civil & Mat Engn, Chicago, IL 60607 USA
[3] Yildirim Beyazit Univ, Dept Civil Engn, TR-06050 Ankara, Turkey
[4] Arkitech Construct Technol, TR-06374 Ankara, Turkey
[5] Univ Illinois, Dept Civil & Mat Engn, Chicago, IL 60607 USA
关键词
Precast concrete; Beam-column connection; Moment resisting connection; Mechanical connection; Nonlinear finite element analysis; Concrete damage plasticity; SEISMIC BEHAVIOR; FRAMES; TESTS; FAILURE; ELEMENTS; SUBJECT; DAMAGE;
D O I
10.1016/j.engstruct.2021.113005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic performance of a specific type of moment resisting precast concrete beam-column connection was investigated through reversed cyclic load tests. Structural steel components were incorporated with precast concrete beam and column elements in the experiments to provide a ductile moment resisting connection. Additionally, nonlinear finite element analysis (FEA) of typical monolithic and precast connections was performed to investigate the performance and failure modes of these connections. Concrete Damage Plasticity (CDP) model was used to capture nonlinearities in concrete under cyclic loading. Good agreement was achieved between experimental and numerical results, which indicates that the finite element model is capable of capturing failure modes of the investigated precast connections. Agreement between the experimental and numerical behaviors was valid in terms of both the global load-displacement response as well as the local response, such as the force within connection rods and the beam curvature. Behavior of the precast concrete connection was influenced significantly by the anchorage detail used for steel connection plates and the beam reinforcement detailing in the vicinity of the connection. Simple detailing modifications resulted in major improvements in the performance of connection in terms of strength, stiffness and energy dissipation characteristics.
引用
收藏
页数:17
相关论文
共 41 条
[11]  
Cheok G.S., 1993, PCI J, V38, P80, DOI 10.15554/ pcij.07011993.80.92
[12]   Development and testing of precast concrete beam-to-column connections [J].
Choi, H. -K. ;
Choi, Y. -C. ;
Choi, C. -S. .
ENGINEERING STRUCTURES, 2013, 56 :1820-1835
[13]  
Chopra AnilK., 2000, Earthquake Spectra, V23, DOI DOI 10.1193/1.1586188
[14]  
Dolan C.W., 1989, PCI J, V34, P84
[15]  
DOLAN CW, 1987, J PRESTR CONCRETE I, V32, P62
[16]   Ductile connections in precast concrete moment resisting frames [J].
Ertas, O ;
Ozden, S ;
Ozturan, T .
PCI JOURNAL, 2006, 51 (03) :66-+
[17]   CONNECTIONS BETWEEN PRECAST ELEMENTS - FAILURE OUTSIDE CONNECTION REGION [J].
FRENCH, CW ;
AMU, O ;
TARZIKHAN, C .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1989, 115 (02) :316-340
[18]   CONNECTIONS BETWEEN PRECAST ELEMENTS - FAILURE WITHIN CONNECTION REGION [J].
FRENCH, CW ;
HAFNER, M ;
JAYASHANKAR, V .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1989, 115 (12) :3171-3192
[19]   Development and testing of hybrid precast concrete beam-to-column connections under cyclic loading [J].
Ghayeb, Haider Hamad ;
Razak, Hashim Abdul ;
Sulong, N. H. Ramli .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 151 :258-278
[20]  
Khoo JH, 2006, ACI STRUCT J, V103, P18