Challenges in the complex management of post-keratoplasty glaucoma

被引:13
作者
Anders, Lisa-Marie [1 ,2 ]
Gatzioufas, Zisis [1 ]
Grieshaber, Matthias C. [1 ]
机构
[1] Univ Hosp Basel, Dept Ophthalmol, CH-4031 Basel, Switzerland
[2] Inst Mol & Clin Ophthalmol Basel, Basel, Switzerland
关键词
DMEK; DSAEK; glaucoma; keratoplasty; GOLDMANN APPLANATION TONOMETRY; POST-PENETRATING-KERATOPLASTY; INTRAOCULAR-PRESSURE ELEVATION; DYNAMIC CONTOUR TONOMETRY; AUTOMATED ENDOTHELIAL KERATOPLASTY; OCULAR RESPONSE ANALYZER; OPEN-ANGLE GLAUCOMA; RISK-FACTORS; BIOMECHANICAL PROPERTIES; CORNEAL TRANSPLANTATION;
D O I
10.1177/25158414211031397
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Glaucoma is a serious complication after corneal transplantation and itself a common cause for graft failure and leading cause of vision loss post-keratoplasty due to corneal endothelial decompensation. Endothelial keratoplasty procedures like Descemet stripping automated endothelial keratoplasty (DSAEK) and Descemet membrane endothelial keratoplasty (DMEK) may be superior to penetrating keratoplasty (PK) regarding the incidence of elevated intraocular pressure (IOP) and development of glaucoma. There are indications that regardless of the method of keratoplasty, some corneal diseases like pseudophakic bullous keratopathy, corneal perforation, and graft rejection have a higher risk for developing post-keratoplasty glaucoma than keratoconus and corneal dystrophies and likewise respond less to IOP lowering therapy. In this review, the pathophysiology of post-keratoplasty glaucoma, the diagnostic tools with focus on different devices, and their limitations with regard to measuring IOP and the treatment modalities are presented.
引用
收藏
页数:11
相关论文
共 105 条
[51]   Intraocular pressure elevation and post-DSEK glaucoma after Descemet's stripping endothelial keratoplasty [J].
Maier, Anna-Karina B. ;
Klamann, Matthias K. J. ;
Torun, Necip ;
Gonnermann, Johannes ;
Schroeter, Jan ;
Joussen, Antonia M. ;
Rieck, Peter .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (04) :1191-1198
[52]   Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements [J].
Martinez-de-la-Casa, Jose M. ;
Garcia-Feijoo, Julian ;
Fernandez-Vidal, Ana ;
Mendez-Hernandez, Carmen ;
Garcia-Sanchez, Julian .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (10) :4410-4414
[53]   Glaucoma risks in advanced corneal surgery [J].
Maurino, Vincenzo ;
Aiello, Francesco .
NEW TRENDS IN BASIC AND CLINICAL RESEARCH OF GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE VISUAL SYSTEM, PT B, 2015, 221 :271-295
[54]   Evaluation of the influence of corneal biomechanical properties on Intraocular pressure measurements using the Ocular Response Analyzer [J].
Medeiros, Felipe A. ;
Weinreb, Robert N. .
JOURNAL OF GLAUCOMA, 2006, 15 (05) :364-370
[55]   Intraocular pressure after penetrating keratoplasty and Descemet's stripping automated endothelial keratoplasty [J].
Moisseiev, Elad ;
Varssano, David ;
Rosenfeld, Elkanah ;
Rachmiel, Rony .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2013, 48 (03) :179-185
[56]   Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes [J].
Mollan, S. P. ;
Wolffsohn, J. S. ;
Nessim, M. ;
Laiquzzaman, M. ;
Sivakumar, S. ;
Hartley, S. ;
Shah, S. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (12) :1661-1665
[57]  
MORI M, 1992, INVEST OPHTH VIS SCI, V33, P416
[58]  
Müller L, 2015, CORNEA, V34, P271, DOI 10.1097/ICO.0000000000000342
[59]   Evolution of Cyclophotocoagulation [J].
Ndulue, Jideofor K. ;
Rahmatnejad, Kamran ;
Sanvicente, Carina ;
Wizov, Sheryl S. ;
Moster, Marlene R. .
JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (01) :55-61
[60]   The Impact of Corneal Edema on Intraocular Pressure Measurements Using Goldmann Applanation Tonometry, Tono-Pen XL, iCare, and ORA: An In Vitro Model [J].
Neuburger, Matthias ;
Maier, Philip ;
Boehringer, Daniel ;
Reinhard, Thomas ;
Jordan, Jens F. .
JOURNAL OF GLAUCOMA, 2013, 22 (07) :584-590