A novel cooling and power cycle based on the absorption power cycle and booster-assisted ejector refrigeration cycle driven by a low-grade heat source: Energy, exergy and exergoeconomic analysis

被引:58
|
作者
Wang, Yazi [1 ]
Chen, Tian [2 ]
Liang, Yingbo [1 ]
Sun, Huaibo [3 ]
Zhu, Yiping [4 ]
机构
[1] ZhouKou Normal Univ, Zhoukou 466001, Henan, Peoples R China
[2] Wuhan Univ Technol, Wuhan 430070, Hubei, Peoples R China
[3] Fuyang Normal Univ, Fuyuang 236037, Anhui, Peoples R China
[4] Tsinghua Univ, Dept Thermal Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Combined cooling and power; ERC; Booster compressor; APC; LGHS; Exergoeconomic analysis; WATER COMBINED POWER; THERMODYNAMIC ANALYSIS; LOW-TEMPERATURE; SYSTEM DRIVEN; THERMOECONOMIC ANALYSIS; OPTIMIZATION; KALINA; RECOVERY;
D O I
10.1016/j.enconman.2019.112321
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nowadays, different renewable sources and energy systems are attracting world attention due to the significant concerns about excessive emissions and the global energy crisis. To achieve both power and cooling supply for users, a new combined cooling and power system is proposed to utilizing low-grade heat sources, such as industrial waste heat, solar energy, and geothermal energy. In this paper, to enhance the efficiency of the traditional power and cooling combined system, a novel system based on the absorption power cycle (APC) and booster-assisted ejector refrigeration system is designed. In the proposed combined power and ejector refrigeration (CPER) cycle, a booster compressor is devised between the ejector and evaporator to enhance the output cooling. The system operates using the low-grade heat source (LGHS). The thermodynamic and thermoeconomics models are developed to analyze the proposed combined power and cooling system, after which, considering the mathematical analysis, the parametric investigation is employed to evaluate the impact of the design parameters on the main performance criteria. The results showed that the proposed system assisted with booster compressor has higher energy efficiency than the traditional APC cycle. The modeling results revealed that the proposed system could provide a cooling capacity of 23.89 kW and the net output power of 18.52 kW by receiving 195.5 kW energy from the low-grade heat source. Also, the first-law efficiency, second-law efficiency, and the total SUCP (Sum unit cost of the product) of the proposed plant are obtained by 21.7%, 52.22%, and 93.52 $/GJ, respectively. From the exergy analysis, it can be inferred that the maximum rate of exergy destruction among all the constitutes of the system belongs to the ejector which constitutes around 27.05% of the overall exergy destruction of system. Besides, the vapor generator 2 is responsible for the 24.31% of total exergy destruction rate. And, the highest cost of exergy destruction corresponds to the condenser followed by ejector. The parametric analysis revealed some valuable results such as a drop in the total SUCP by decreasing vapor generator 1 hot PPTD (Pinch point temperature difference), final absorption temperature, turbine inlet pressure, and LiBr mass fraction. The cooling output capacity is increasing by the increment of vapor generator 1 hot PPTD, turbine inlet pressure, and LiBr mass fraction.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Employing thermoelectric generator and booster compressor for performance improvement of a geothermal driven combined power and ejector-refrigeration cycle
    Takleh, H. Rostamnejad
    Zare, V.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 186 : 120 - 130
  • [22] Thermodynamic analysis of a novel combined power and refrigeration cycle comprising of EKalina and ejector refrigeration cycles
    Behnam, Pooria
    Faegh, Meysam
    Shafii, Mohammad Behshad
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 104 : 291 - 301
  • [23] A combined power and ejector refrigeration cycle for low temperature heat sources
    Zheng, B.
    Weng, Y. W.
    SOLAR ENERGY, 2010, 84 (05) : 784 - 791
  • [24] Techno-economic assessment of low-grade geothermal heat-driven ejector refrigeration cycle with a flash chamber and a booster compressor
    Chitta Sahana
    Sudipta De
    Subha Mondal
    Clean Technologies and Environmental Policy, 2024, 26 : 1089 - 1106
  • [25] Analysis of a power cycle utilizing low-grade solar energy
    Song, Jianzhong
    Zhang, Xiaosong
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [26] Analysis of a Combined Power and Ejector-Refrigeration Cycle Based on Solar Energy
    Sheykhlou, H.
    Jafarmadar, S.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2016, 40 (01) : 57 - 67
  • [27] Performance analysis of a new ejector expansion refrigeration cycle (NEERC) for power and cold: Exergy and energy points of view
    Megdouli, K.
    Tashtoush, B. M.
    Ezzaalouni, Y.
    Nandi, E.
    Mhimid, A.
    Kairouani, L.
    APPLIED THERMAL ENGINEERING, 2017, 122 : 39 - 48
  • [28] Proposal and assessment of a novel geothermal combined cooling and power cycle based on Kalina and ejector refrigeration cycles
    Ghaebi, Hadi
    Parikhani, Towhid
    Rostamzadeh, Hadi
    Farhang, Behzad
    APPLIED THERMAL ENGINEERING, 2018, 130 : 767 - 781
  • [29] Performance analysis of a biomass-fired cooling/power combined cycle (Ejector Refrigeration and Kalina cycle)
    Seckin, Candeniz
    2019 5TH INTERNATIONAL CONFERENCE ON POWER GENERATION SYSTEMS AND RENEWABLE ENERGY TECHNOLOGIES (PGSRET-2019), 2019, : 100 - 105
  • [30] Thermodynamic and thermoeconomic analysis and optimization of a novel combined cooling and power (CCP) cycle by integrating of ejector refrigeration and Kalina cycles
    Ghaebi, Hadi
    Parikhani, Towhid
    Rostamzadeh, Hadi
    Farhang, Behzad
    ENERGY, 2017, 139 : 262 - 276