Hot spot temperature inversion for the single-core power cable joint

被引:25
|
作者
Ruan, Jiang-jun [1 ]
Liu, Chao [1 ]
Huang, Dao-chun [1 ]
Zhan, Qing-hua [2 ]
Tang, Lie-Zheng [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Room 419, Wuhan, Peoples R China
[2] Foshan Power Co China Southern Power Grid, Foshan, Peoples R China
关键词
Cable joint; FEM; Thermal circuit; Temperature inversion;
D O I
10.1016/j.applthermaleng.2016.05.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Monitoring temperature inside the power cable joint is of great meaning to the safety of power distribution, while measuring it directly is infeasible. In this paper, the authors propose a new method to invert real-time hot spot temperature of conductor in the single-core power cable joint. This method consists of two parts, the radial-direction temperature inversion (RDTI) in the cable and axial-direction temperature inversion (ADTI) in the conductor. With this method, hot spot temperature of conductor in the cable joint could be figured out with the surface temperatures of the cable nearby the cable joint and load current, both of which are measurable. Then, the authors carry it out on an actual power cable joint in the laboratory, and the inversed temperatures are compared with experiment data, which come from the indoor experiment platform, to validate the availability of this method. The maximum error of this method is 6%, and it shows that this method for temperature inversion is feasible in laboratory scale. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:146 / 152
页数:7
相关论文
共 50 条
  • [1] Study on Temperature Cascade ELM Inversion Method for 110 kV Single-Core Cable Intermediate Joints
    Li, Xinhai
    Feng, Bao
    Wang, Zhengang
    Ruan, Jiangjun
    Xiao, Chang
    PROCESSES, 2024, 12 (05)
  • [2] Calculation of AC Resistance for Stranded Single-Core Power Cable Conductors
    Dai, Dong
    Zhang, Xiaohui
    Wang, Juanjuan
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (11)
  • [3] Study on the ampacity of single-core submarine power cable with return conductor
    Fan Youbing
    Liu Songhua
    Li Te
    Deng Xianbo
    2019 INTERNATIONAL CONFERENCE ON ADVANCED ELECTRONIC MATERIALS, COMPUTERS AND MATERIALS ENGINEERING (AEMCME 2019), 2019, 563
  • [4] Development of optical fibers incorporated single-core submarine power cable
    Ogata, Sciichi
    Fujii, Koichiro
    Nishino, Isao
    Hata, Ryosuke
    Yoshikawa, Noriyaso
    Hirose, Masayuki
    Koga, Hisao
    Tanaka, Shigero
    Osaka, Keiji
    Sumitomo Electric Technical Review, 1994, (37):
  • [5] Research on shielding overvoltage of single-core cable
    Niu, H. Q.
    Wang, X. B.
    Shi, Y. X.
    Zhang, Y.
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 1317 - +
  • [6] Working temperature calculation of single-core cable by nonlinear finite element method
    Meng, Xiaokai
    Han, Peijie
    Liu, Yongxin
    Lu, Zhumao
    Jin, Tao
    ARCHIVES OF ELECTRICAL ENGINEERING, 2019, 68 (03) : 643 - 656
  • [7] Calculation and Test for Ampacity of Underground Single-core Cable
    Chen, Yanping
    Niu, Haiqing
    Zhou, Xin
    Wang, Xiaobing
    Zhang, Yao
    Fan, Youbing
    Zhao, Jiankang
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3885 - +
  • [8] Study of ampacity of single-core cable based on iterative method
    Niu, Haiqing
    Wang, Xiaobing
    Zhang, Yao
    Gaodianya Jishu/High Voltage Engineering, 2006, 32 (11): : 41 - 44
  • [9] Experimental analysis on increasing temporary ampacity of single-core cable
    Liu, Gang
    Lei, Cheng-Hua
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (05): : 1288 - 1293
  • [10] Technical parameters design of over voltage protector for single-core power cable shield sheath
    Wuhan High Voltage Research Institute, SGCC, Wuhan 430074, China
    不详
    不详
    Gaodianya Jishu, 2008, 2 (355-358+372): : 355 - 358