Comparison of dynamic contour tonometry and Goldmann applanation tonometry following penetrating keratoplasty

被引:6
|
作者
Kandarakis, Artemios [1 ]
Soumplis, Vasileios [1 ]
Pitsas, Christos [1 ]
Kandarakis, Stylianos [2 ]
Halikias, Jiannis [3 ]
Karagiannis, Dimitrios [1 ]
机构
[1] Athens Eye Hosp, A Eye Clin, Athens 10672, Greece
[2] Mt Sinai Sch Med, Dept Ophthalmol, New York, NY USA
[3] Athens Univ Econ, Dept Mkt & Commun, Athens, Greece
关键词
dynamic contour tonometry; Goldmann applanation tonometry; intraocular pressure; penetrating keratoplasty; MEASURING INTRAOCULAR-PRESSURE; CENTRAL CORNEAL THICKNESS; TONO-PEN; POSTKERATOPLASTY EYES; GLAUCOMA;
D O I
10.3129/i10-035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) intraocular pressure (IOP) measurements in eyes that underwent penetrating keratoplasty (PKP). Design: Prospective, cross-sectional, observational study. Participants: Thirty-one eyes of 28 patients were examined after PKP. Methods: All eyes had undergone PKP with interrupted sutures. The postoperative period was more than 1 year for 25 eyes and less than 1 year for 6. Sutures were removed based on corneal topography and refraction. IOP was measured by both DCT and GAT methods and was correlated to the number of remaining sutures. Results: IOP readings were successfully obtained in 25/31 (80.6%) with DTC and in 21/31(67.7%) with GAT (p = 0.25). In eyes with fewer than 4 remaining sutures, both methods were successful. In eyes with more than 4 sutures, the success rates of DCT and GAT were 66.7% and 44.4%, respectively (p = 0.18). In PKPs with a postoperative period of more than I year, the success rates of DCT and GAT were 96% and 84%, respectively (p = 0.16). In 20 eyes, both methods measured the IOP. The mean IOP obtained by DCT (16.6 [SD 2.8] mm Hg) was higher than the mean IOP obtained from GAT (15.1 [SD 3.6] mm Hg). The IOPs from the 2 instruments correlated significantly (p < 0.05) and the mean difference was 1.5 mm Hg. Conclusions: The success rate in measuring IOP with DCT and GAT did not show any statistically significant difference. Both methods were less effective measuring the IOP after recent PKPs and regrafts. However, DCT seemed to be superior to GAT in corneas with more than 4 remaining sutures and in PKPs performed more than 1 year earlier. The absolute values of IOP were higher with DCT than with GAT.
引用
收藏
页码:489 / 493
页数:5
相关论文
共 50 条
  • [41] The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
    Kotecha, A
    White, ET
    Shewry, JM
    Garway-Heath, DF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [42] Dynamic contour tonometry and Goldmann applanation tonometry: correlation with intracameral assessment of intraocular pressure
    Riva, Ivano
    Quaranta, Luciano
    Russo, Andrea
    Katsanos, Andreas
    Rulli, Eliana
    Floriani, Irene
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (01) : 55 - 62
  • [43] Comparison of PASCAL contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects
    Barleon, L
    Hoffmann, EM
    Pfeiffer, N
    Grus, FH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [44] GOLDMANN APPLANATION TONOMETRY VERSUS DYNAMIC CONTOUR TONOMETRY IN LASIK FOR HYPEROPIA AND PRK FOR MYOPIA
    Goggin, Michael
    Moore, Sacha
    Estermann, Adrian
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 : 29 - 29
  • [45] Comparison of Goldmann applanation and dynamic contour tonometry before and after cataract surgery
    Heinrich, Mitja A.
    Eppig, Timo
    Langenbucher, Achim
    Walter, Sven
    Behrens-Baumann, Wolfgang
    Viestenz, Arne
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 683 - 689
  • [46] Comparison of Intraocular Pressure Measurements With Goldmann Applanation Tonometry, Tonopen XL, and Pascal Dynamic Contour Tonometry in Patients With Descemet Membrane Endothelial Keratoplasty
    Yildiz, Izlem
    Altan, Cigdem
    Cakmak, Semih
    Genc, Selim
    Yildirim, Yusuf
    Agca, Alper
    JOURNAL OF GLAUCOMA, 2022, 31 (11) : 909 - 914
  • [47] Comparison of proview phosphene tonometry with Goldmann applanation tonometry
    Morledge-Hampton, Scott J.
    Kwon, Robert O.
    Krishna, Rohit
    Debry, Peter W.
    Willoughby, Thomas L.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2006, 41 (06): : 722 - 726
  • [48] Clinical evaluation of applanation resonance tonometry -: A comparison with Goldmann applanation tonometry
    Hallberg, Per
    Eklund, Anders
    Backlund, Tomas
    Linden, Christina
    JOURNAL OF GLAUCOMA, 2007, 16 (01) : 88 - 93
  • [49] Effect of Corneal Morphometry on Dynamic Contour and Goldmann Applanation Tonometry
    Saenz-Frances, Federico
    Janez, Luis
    Borrego-Sanz, Lara
    Maria Martinez-de-la-Casa, Jose
    Jerez-Fidalgo, Maria
    Garcia-Sanchez, Julian
    Garcia-Feijoo, Julian
    JOURNAL OF GLAUCOMA, 2013, 22 (05) : 380 - 383
  • [50] Comparison of Goldmann applanation tonometry and dynamic contour tonometry for measuring intraocular pressure in normal tension glaucomatous eyes
    Wang, Jing Grace
    Latina, Mark A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)