Comparison of dynamic contour tonometry and Goldmann applanation tonometry following penetrating keratoplasty

被引:6
|
作者
Kandarakis, Artemios [1 ]
Soumplis, Vasileios [1 ]
Pitsas, Christos [1 ]
Kandarakis, Stylianos [2 ]
Halikias, Jiannis [3 ]
Karagiannis, Dimitrios [1 ]
机构
[1] Athens Eye Hosp, A Eye Clin, Athens 10672, Greece
[2] Mt Sinai Sch Med, Dept Ophthalmol, New York, NY USA
[3] Athens Univ Econ, Dept Mkt & Commun, Athens, Greece
关键词
dynamic contour tonometry; Goldmann applanation tonometry; intraocular pressure; penetrating keratoplasty; MEASURING INTRAOCULAR-PRESSURE; CENTRAL CORNEAL THICKNESS; TONO-PEN; POSTKERATOPLASTY EYES; GLAUCOMA;
D O I
10.3129/i10-035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) intraocular pressure (IOP) measurements in eyes that underwent penetrating keratoplasty (PKP). Design: Prospective, cross-sectional, observational study. Participants: Thirty-one eyes of 28 patients were examined after PKP. Methods: All eyes had undergone PKP with interrupted sutures. The postoperative period was more than 1 year for 25 eyes and less than 1 year for 6. Sutures were removed based on corneal topography and refraction. IOP was measured by both DCT and GAT methods and was correlated to the number of remaining sutures. Results: IOP readings were successfully obtained in 25/31 (80.6%) with DTC and in 21/31(67.7%) with GAT (p = 0.25). In eyes with fewer than 4 remaining sutures, both methods were successful. In eyes with more than 4 sutures, the success rates of DCT and GAT were 66.7% and 44.4%, respectively (p = 0.18). In PKPs with a postoperative period of more than I year, the success rates of DCT and GAT were 96% and 84%, respectively (p = 0.16). In 20 eyes, both methods measured the IOP. The mean IOP obtained by DCT (16.6 [SD 2.8] mm Hg) was higher than the mean IOP obtained from GAT (15.1 [SD 3.6] mm Hg). The IOPs from the 2 instruments correlated significantly (p < 0.05) and the mean difference was 1.5 mm Hg. Conclusions: The success rate in measuring IOP with DCT and GAT did not show any statistically significant difference. Both methods were less effective measuring the IOP after recent PKPs and regrafts. However, DCT seemed to be superior to GAT in corneas with more than 4 remaining sutures and in PKPs performed more than 1 year earlier. The absolute values of IOP were higher with DCT than with GAT.
引用
收藏
页码:489 / 493
页数:5
相关论文
共 50 条
  • [31] Comparison of the Utility of Pascal Dynamic Contour Tonometry With Goldmann Applanation Tonometry in Routine Clinical Practice
    Anderson, Matthew Frederick
    Agius-Fernandez, Adriana
    Kaye, Stephen B.
    JOURNAL OF GLAUCOMA, 2013, 22 (05) : 422 - 426
  • [32] Dynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard
    Bochmann, Frank
    Kaufmann, Claude
    Thiel, Michael A.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2010, 5 (06) : 743 - 749
  • [33] Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry in pseudoexfoliation syndrome
    Grammenandi, Emilia
    Detorakis, Efstathios T.
    Pallikaris, Ioannis G.
    Tsilimbaris, Miltiadis K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (05): : 444 - 448
  • [34] Evaluation of correction formulas for tonometry. The Goldmann applanation tonometry in approximation to dynamic contour tonometry
    Wachtl, J.
    Toeteberg-Harms, M.
    Frimmel, S.
    Kniestedt, C.
    OPHTHALMOLOGE, 2017, 114 (08): : 716 - 721
  • [35] Comparison of Goldmann applanation tonometry and Icare tonometry
    Yu, Zhaohua
    Edenteg, Johan
    Raeme, Faisal
    Soderberg, Per
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [36] Comparison of Goldmann Tonometry and Dynamic Contour Tonometry in Normal and Descemet Stripping Endothelial Keratoplasty Eyes
    Pal, Dipanjan
    Sengupta, Jayangshu
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2013, 2 (03): : 159 - 164
  • [37] Corneal thickness and Intraocular pressure After DSAEK: comparison of Dynamic Contour tonometry with Goldmann Applanation tonometry
    Borges, Barbara
    Vicente, Andre
    Anjos, Rita
    Vieira, Luisa
    Santos, Arnaldo Dias
    Ferreira, Joana
    Maduro, Vitor
    Alves, Nuno
    Feijao, Joao
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [38] Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry
    Herr, Anne
    Remky, Andreas
    Hirsch, Thalia
    Rennings, Corinna
    Plange, Niklas
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 815 - 819
  • [39] The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
    Kotecha, A
    White, ET
    Shewry, JM
    Garway-Heath, DF
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1572 - 1575
  • [40] Goldmann Applanation Tonometry and Dynamic Contour Tonometry After Treatment With Prostaglandin Analog/Prostamide
    Ang, Ghee Soon
    Wells, Anthony P.
    JOURNAL OF GLAUCOMA, 2010, 19 (05) : 346 - 346