BACKGROUND Small vegetations (<2.0 cm) associated with infected cardiac device leads can be managed percutaneously, whereas larger vegetations typically are removed via open heart surgery. Unfortunately, many patients with intracardiac vegetations are not candidates for open removal. OBJECTIVE The purpose of this study was to report our experience in the outcomes associated with the percutaneous management of large vegetations. METHODS Prospective data from January 2010 to August 2018 identified 826 patients with infections undergoing lead extraction. One hundred nineteen cases had vegetations measured in 2 dimensions (length and width) by transesophageal echocardiogram. Thirty-two patients had 3 characteristics: (1) at least 1 vegetation dimension >= 2.0 cm; (2) not a surgical candidate; and (3) had undergone transvenous lead extraction. The cohort was classified into 2 groups according to shape: (1) globular if the difference between dimensions was <30% between dimensions; and (2) nonglobular if the difference was >30%. The Fisher exact test and Pearson t test were used for analysis. P <.05 was considered significant. RESULTS Retrospective analysis of a single tertiary cardiac surgery center registry showed a significantly lower chance of being alive at discharge in patients with globular vegetations compared to patients with nonglobular vegetations (P = .002). CONCLUSION Vegetation size is an important determinant of outcomes in patients who are not surgical candidates undergoing transvenous lead extraction. However, vegetation shape is also a relevant factor, as globular vegetations may predict a worse result compared to nonglobular vegetations.
引用
收藏
页码:646 / 653
页数:8
相关论文
共 35 条
  • [31] Stevens D, 2015, J VASC INTERV RADIOL, V26, P150
  • [32] Vegetectomy in Brucella endocarditis
    Sunar, H
    Duran, E
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (06) : 2036 - 2036
  • [33] Antibacterial Envelope to Prevent Cardiac Implantable Device Infection
    Tarakji, Khaldoun G.
    Mittal, Suneet
    Kennergren, Charles
    Corey, Ralph
    Poole, Jeanne E.
    Schloss, Edward
    Gallastegui, Jose
    Pickett, Robert A.
    Evonich, Rudolph
    Philippon, Francois
    McComb, Janet M.
    Roark, Steven F.
    Sorrentino, Denise
    Sholevar, Darius
    Cronin, Edmond
    Berman, Brett
    Riggio, David
    Biffi, Mauro
    Khan, Hafiza
    Silver, Marc T.
    Collier, Jack
    Eldadah, Zayd
    Wright, David J.
    Lande, Jeff D.
    Lexcen, Daniel R.
    Cheng, Alan
    Wilkoff, Bruce L.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (20) : 1895 - 1905
  • [34] Pacemaker lead infection: report of three cases and review of the literature
    Voet, JG
    Vandekerckhove, YR
    Muyldermans, LL
    Missault, LH
    Matthys, LJ
    [J]. HEART, 1999, 81 (01) : 88 - 91
  • [35] Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative Insights