Film and digital radiography for detection of simulated root resorption cavities

被引:42
作者
Borg, E [1 ]
Kallqvist, A [1 ]
Grondahl, K [1 ]
Grondahl, HG [1 ]
机构
[1] Univ Goteborg, Fac Odontol, Dept Oral Diagnost Radiol, SE-40530 Gothenburg, Sweden
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1998年 / 86卷 / 01期
关键词
D O I
10.1016/S1079-2104(98)90159-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The purpose of this study was to evaluate observers' ability to detect simulated root resorption cavities in conventional radiographs and digital radiographs from a charge-coupled device system and a storage phosphor system and to determine whether the detectability was influenced by resorption size and exposure. Study design. In teeth from dry mandibular jaw specimens, resorptive defects 1.2 mm in diameter and at two different depths (0.6 and 0.9 mm) were prepared in the buccal root surface. Each tooth was radiographed at a number of different exposure settings. Observers were asked to rate their confidence that a resorption was or was not present using a five-graded confidence scale. Receiver operating characteristic analysis was used to evaluate the results. Results and conclusion. Given optimal exposures, all systems reached what might be considered clinically acceptable A,values (>0.75). The storage phosphor system reached this value at considerably lower exposures than those required for both the film and charge-coupled device systems. There was a tendency to better detect the deeper lesions and to identify them at lower exposures.
引用
收藏
页码:110 / 114
页数:5
相关论文
共 29 条
  • [21] INFLUENCE OF STRUCTURED NOISE ON DETECTION OF RADIOLOGIC ABNORMALITIES
    REVESZ, G
    KUNDEL, HL
    GRABER, MA
    [J]. INVESTIGATIVE RADIOLOGY, 1974, 9 (06) : 479 - 486
  • [22] IMAGE QUALITY OF DIRECT DIGITAL INTRAORAL X-RAY SENSORS IN ASSESSING ROOT-CANAL LENGTH - THE RADIOVISIOGRAPHY, VISUALIX VIXA, SENS-A-RAY, AND FLASH DENT SYSTEMS COMPARED WITH EKTASPEED FILMS
    SANDERINK, GCH
    HUISKENS, R
    VANDERSTELT, PF
    WELANDER, US
    STHEEMAN, SE
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (01): : 125 - 132
  • [23] Dose reduction of two digital sensor systems measuring file lengths
    Velders, XL
    Sanderink, GCH
    vanderStelt, PF
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (05): : 607 - 612
  • [24] Estimating distances on direct digital images and conventional radiographs
    Versteeg, KH
    Sanderink, GCH
    VanGinkel, FC
    VanderStelt, PF
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (04) : 439 - 443
  • [25] WAKOH M, 1994, ORAL RADIOL, V10, P33
  • [26] BASIC TECHNICAL PROPERTIES OF A SYSTEM FOR DIRECT ACQUISITION OF DIGITAL INTRAORAL RADIOGRAPHS
    WELANDER, U
    NELVIG, P
    TRONJE, G
    MCDAVID, WD
    DOVE, SB
    MORNER, AC
    CEDERLUND, T
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1993, 75 (04): : 506 - 516
  • [27] ABSOLUTE MEASURES OF IMAGE QUALITY FOR THE SENS-A-RAY DIRECT DIGITAL INTRAORAL RADIOGRAPHY SYSTEM
    WELANDER, U
    MCDAVID, WD
    MORNER, AC
    TRONJE, G
    TOKUOKA, O
    FUCHIHATA, H
    NELVIG, P
    DOVE, SB
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (03): : 345 - 350
  • [28] Wenzel A, 1995, Int Dent J, V45, P27
  • [29] ACCURACY OF CARIES DIAGNOSIS IN DIGITAL IMAGES FROM CHARGE-COUPLED-DEVICE AND STORAGE PHOSPHOR SYSTEMS - AN IN-VITRO STUDY
    WENZEL, A
    BORG, E
    HINTZE, H
    GRONDAHL, HG
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (04) : 250 - 254