Film and digital radiography for detection of simulated root resorption cavities

被引:42
作者
Borg, E [1 ]
Kallqvist, A [1 ]
Grondahl, K [1 ]
Grondahl, HG [1 ]
机构
[1] Univ Goteborg, Fac Odontol, Dept Oral Diagnost Radiol, SE-40530 Gothenburg, Sweden
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1998年 / 86卷 / 01期
关键词
D O I
10.1016/S1079-2104(98)90159-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The purpose of this study was to evaluate observers' ability to detect simulated root resorption cavities in conventional radiographs and digital radiographs from a charge-coupled device system and a storage phosphor system and to determine whether the detectability was influenced by resorption size and exposure. Study design. In teeth from dry mandibular jaw specimens, resorptive defects 1.2 mm in diameter and at two different depths (0.6 and 0.9 mm) were prepared in the buccal root surface. Each tooth was radiographed at a number of different exposure settings. Observers were asked to rate their confidence that a resorption was or was not present using a five-graded confidence scale. Receiver operating characteristic analysis was used to evaluate the results. Results and conclusion. Given optimal exposures, all systems reached what might be considered clinically acceptable A,values (>0.75). The storage phosphor system reached this value at considerably lower exposures than those required for both the film and charge-coupled device systems. There was a tendency to better detect the deeper lesions and to identify them at lower exposures.
引用
收藏
页码:110 / 114
页数:5
相关论文
共 29 条
  • [1] ANDREASEN F M, 1987, Endodontics and Dental Traumatology, V3, P21
  • [2] ANDREASEN JO, 1980, SWED DENT J, V4, P101
  • [3] ANDREASEN JO, 1980, SWED DENT J, V4, P135
  • [4] On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems
    Borg, E
    Grondahl, HG
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) : 82 - 88
  • [5] Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems - An in vitro study
    Borg, E
    Grondahl, K
    Grondahl, HG
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (05) : 306 - 312
  • [6] EXTERNAL ROOT RESORPTION - AN EXPERIMENTAL RADIOGRAPHIC EVALUATION
    CHAPNICK, L
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 67 (05): : 578 - 582
  • [7] X-RAY IMAGE SUBTRACTION BY DIGITAL MEANS
    CHOW, CK
    HILAL, SK
    NIEBUHR, KE
    [J]. IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1973, 17 (03) : 206 - 218
  • [8] DIRECT DIGITAL RADIOGRAPHY FOR THE DETECTION OF PERIODONTAL BONE-LESIONS
    FURKART, AJ
    DOVE, SB
    MCDAVID, WD
    NUMMIKOSKI, P
    MATTESON, S
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 74 (05): : 652 - 660
  • [9] Grondahl H G, 1996, Dent Update, V23, P334
  • [10] GRONDAHL K, 1987, SWED DENT J S, V50