Radioluminescence of silica optical fibre scintillators for real-time industrial radiation dosimetry

被引:7
作者
Oresegun, Adebiyi [1 ]
Basaif, A. [1 ]
Tarif, Zubair H. [1 ,2 ]
Abdul-Rashid, H. A. [1 ]
Hashim, Siti Aiasah [3 ]
Bradley, D. A. [4 ,5 ]
机构
[1] Multimedia Univ, Fac Engn, Fibre Opt Res Ctr, Jalan Multimedia, Cyberjaya 63100, Malaysia
[2] Lumisysns Technol Sdn Bhd, Cyberjaya 63100, Selangor, Malaysia
[3] Agensi Nuklear Malaysia, Alurtron Electron Beam Irradiat Ctr, Kajang 43000, Selangor, Malaysia
[4] Sunway Univ, Sch Engn & Technol, Ctr Appl Phys & Radiat Technol, Pj 46150, Malaysia
[5] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
Radioluminescence; Real-time dosimetry; Optical fibre scintillator; Industrial radiation; SI NANOCRYSTALS; LUMINESCENCE; PHOTOLUMINESCENCE; DEFECTS; CENTERS; DICHROMATE; GLASSES; BAND;
D O I
10.1016/j.radphyschem.2021.109684
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dosimetry systems are important in any radiation facility to ensure quality, safety, validation, qualification and quality control of established and new processes, including at industrial radiation facilities. We present a study of silica optical fibre as scintillators for industrial radiation dosimetry using Radioluminescence (RL). The RL technique provides for a remote and real-time dosimetry measurement in such a high dose environment. This study establishes the dosimetric characteristics of two variants of pure silica optical fibre, low and high hydroxyl (OH) when exposed to industrial radiation levels. The samples were exposed to a linear accelerator, with doses in the order of tens of kGy (from 10 kGy through to 70 kGy in individual exposures). The performance parameters observed during the study include the RL emission spectrum, emission intensity and emission linearity with exposure dose. The RL spectrum demonstrated a central wavelength of 650 nm and 550 nm for the high and low OH scintillators, respectively. RL intensity was observed to increase with exposed dose, a result of recombination of ionizing radiation generated electron-hole pairs. The RL intensity relation with exposed dose indicated a linear response, with the higher OH sample showing the greater slope, indicating greater sensitivity. The overall results indicate the potential use of pure silica optical fibre as scintillators for remote and real-time industrial radiation dosimetry.
引用
收藏
页数:6
相关论文
共 50 条
[31]   Coupled ionizing-radiation/optical-photon transport Monte Carlo simulations for characterisation of light signal in an optical fiber radioluminescence dosimetry system [J].
Moradi, F. ;
Oresegun, A. ;
Khodaei, A. ;
Bradley, D. A. ;
Taheri, A. ;
Khandaker, M. U. ;
Abdul-Rashid, H. A. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2025, 11 (02)
[32]   Real-time dosimetry in interventional radiology - comparing the occupational radiation exposure in fluoroscopy-guided lower extremity and abdominal procedures [J].
Krompass, Kristina ;
Mutschler, Mareike ;
Grunz, Jan-Peter ;
Thurner, Annette ;
Bley, Thorsten Alexander ;
Voelker, Wolfram ;
Kickuth, Ralph .
EUROPEAN RADIOLOGY, 2025,
[33]   Poor predictive value of intraoperative real-time dosimetry for prostate seed brachytherapy [J].
Igidbashian, Levon ;
Donath, David ;
Carrier, Jean-Francois ;
Lassalle, Stephanie ;
Hervieux, Yannick ;
David, Sandrine ;
Bahary, Jean-Paul ;
Taussky, Daniel .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (02) :605-609
[34]   Performance characterisation of a real-time fiber dosimetry system using radiophotoluminescent glasses [J].
Kurobori, Toshio .
JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (10)
[35]   <bold>Wireless Real-Time Gamma Radiation Dosimetry System Using MgO and CeO2 Thick Film Capacitors</bold> [J].
Arshak, K. ;
Kaneswaran, K. ;
Korostynska, O. ;
Morris, D. ;
Arshak, A. .
PROCEEDINGS OF THE 2006 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2006, :60-65
[36]   An Innovative Real-Time Dosimeter for Radiation Hardness Assurance Tests [J].
Campajola, Luigi ;
Casolaro, Pierluigi ;
Gandolfo, Elisa Maria ;
Campajola, Marcello ;
Buontempo, Salvatore ;
Di Capua, Francesco .
PHYSICS, 2022, 4 (02) :409-420
[37]   Real-time in vivo dosimetry for SBRT prostate treatment using plastic scintillating dosimetry embedded in a rectal balloon: a case study [J].
Cantley, Justin L. ;
Cheng, Chee-Wai ;
Jesseph, Fredrick B. ;
Podder, Tarun K. ;
Colussi, Valdir C. ;
Traughber, Bryan J. ;
Ponsky, Lee E. ;
Ellis, Rodney J. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06) :305-311
[38]   REAL-TIME IN VIVO DOSIMETRY WITH MOSFET DETECTORS IN SERIAL TOMOTHERAPY FOR HEAD AND NECK CANCER PATIENTS [J].
Qi, Zhen-Yu ;
Deng, Xiao-Wu ;
Huang, Shao-Min ;
Shiu, Almon ;
Lerch, Michael ;
Metcalfe, Peter ;
Rosenfeld, Anatoly ;
Kron, Tomas .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05) :1581-1588
[39]   Fiber-Coupled, Time-Gated Al2O3 : C Radioluminescence Dosimetry Technique and Algorithm for Radiation Therapy With LINACs [J].
Magne, Sylvain ;
Deloule, Sybelle ;
Ostrowsky, Aime ;
Ferdinand, Pierre .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) :2998-3007
[40]   Real-Time Detection of Gas and Chemical Vapor Flows by Silica Inverse-Opals [J].
Chaghamirzaei, Pouria ;
Raeyani, Davoud ;
Khosravi, Aynour ;
Allahveisi, Shahin ;
Abdollahi-Kia, Behrad ;
Bayat, Farzaneh ;
Olyaeefar, Babak ;
Ahmadi-Kandjani, Sohrab .
IEEE SENSORS JOURNAL, 2019, 19 (18) :7961-7967