Impact of High-Speed Sintering on Accuracy and Fit of 4 mol% Yttria-Stabilized Tetragonal Zirconia Polycrystals

被引:3
作者
Anton, Xenia [1 ]
Stawarczyk, Bogna [1 ]
Reymus, Marcel [2 ]
Joda, Tim [3 ]
Liebermann, Anja [4 ]
机构
[1] Ludwig Maximilian Univ Munich, Univ Hosp, Dept Prosthet Dent, Dent Mat Unit, Munich, Germany
[2] Ludwig Maximilian Univ Munich, Univ Hosp, Dept Conservat Dent & Periodontol, Munich, Germany
[3] Univ Basel, Univ Ctr Dent Med Basel, Dept Reconstruct Dent, Basel, Switzerland
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Goethestr 70, D-80336 Munich, Germany
关键词
MARGINAL ADAPTATION; DENTAL CAD/CAM; INTERNAL FIT; GRAIN-SIZE; CAD-CAM; RESTORATIONS; CERAMICS; CROWNS;
D O I
10.11607/ijp.7428
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To investigate the impact of high-speed sintering on the accuracy (ie, trueness and reproducibility) and fit of yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP) full-coverage single-unit fixed dental prostheses (FDPs) and three-unit FDPs. Materials and Methods: Single-unit FDPs, conventional three-unit FDPs, and cantilever three-unit FDPs (N = 108; n = 12 per subgroup) were fabricated from: (1) high-speed-sintered (1,580 degrees C, about 20 minutes) multi-layer 4Y-TZP (Zolid RS [ZMLH]), as well as two conventionally sintered (1,450 degrees C, about 10 hours) materials: (2) multi-layer 4Y-TZP (Zolid Gen-X [ZMLC]) and (3) monochrome 4Y-TZP (Ceramill Zolid HT+ PS [ZMOC]). All specimens were scanned, and trueness, reproducibility, and fit were measured with 3D analysis software. For data analysis, Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U tests were performed (alpha = .05). Results: Three-unit FDPs made from ZMLH presented a deterioration of accuracy in comparison to ZMLC (P <= .001 to .008). The influence of high-speed sintering on marginal and general fit was not clinically relevant (P = .154 to .877). Conclusion: High-speed sintering influenced the accuracy of 4Y-TZP full-coverage single-unit and three-unit FDPs. However, no clinically relevant impact on fit was observed.
引用
收藏
页码:775 / 783
页数:9
相关论文
共 35 条
[1]   FIT OF 3 PORCELAIN-FUSED-TO-METAL MARGINAL DESIGNS INVIVO - A SCANNING ELECTRON-MICROSCOPE STUDY [J].
BELSER, UC ;
MACENTEE, MI ;
RICHTER, WA .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (01) :24-29
[2]   Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns [J].
Bindl, A ;
Mörmann, WH .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2003, 111 (02) :163-169
[3]  
Boitelle P, 2018, J PROSTHET DENT, V119, P75, DOI 10.1016/j.prosdent.2017.01.026
[4]   A 3-DIMENSIONAL ACCURACY ANALYSIS OF CHAIRSIDE CAD/CAM MILLING PROCESSES [J].
Bosch, Gabriel ;
Ender, Andreas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06) :1425-1431
[5]  
Burde AV, 2016, MATER PLAST, V53, P65
[6]   New Y-TZP powders for medical grade zirconia [J].
Burger, W ;
Richter, HG ;
Piconi, C ;
Vatteroni, R ;
Cittadini, A ;
Boccalari, M .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (02) :113-118
[7]  
Church Todd D., 2017, General Dentistry, V65, P48
[8]   Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol [J].
Dahl, Bjorn Einar ;
Ronold, Hans Jacob ;
Dahl, Jon E. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (03) :400-404
[9]   State of the art of zirconia for dental applications [J].
Denry, Isabelle ;
Kelly, J. Robert .
DENTAL MATERIALS, 2008, 24 (03) :299-307
[10]   Effect of changes in sintering parameters on monolithic translucent zirconia [J].
Ebeid, Kamal ;
Wille, Sebastian ;
Hamdy, Amina ;
Salah, Tarek ;
El-Etreby, Amr ;
Kern, Matthias .
DENTAL MATERIALS, 2014, 30 (12) :E419-E424