A comparison of articaine and lidocaine for inferior alveolar nerve blocks

被引:133
作者
Mikesell, P
Nusstein, J
Reader, A
Beck, M
Weaver, J
机构
[1] Ohio State Univ, Coll Dent, Dept Endodont, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Oral Biol, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Oral Surg, Columbus, OH 43210 USA
[4] Ohio State Univ, Dept Oral Pathol, Columbus, OH 43210 USA
[5] Ohio State Univ, Dept Anesthesiol, Columbus, OH 43210 USA
关键词
D O I
10.1097/01.don.0000140576.36513.cb
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this prospective, randomized, double-blind study was to compare the degree of pulpal anesthesia obtained With 4% articaine with 1:100,000 epinephrine and 2% lidocaine with 1:100,000 epinephrine in inferior alveolar nerve blocks. Using a crossover design, inferior alveolar nerve blocks were randomly administered, in a double-blind manner, using 4% articaine with 1:100,000 epinephrine and 2% lidocaine with 1:100,000 epinephrine, at two separate appointments, to 57 subjects. A pulp tester was used to test for anesthesia, in 4-min cycles for 60 min, of the molars, premolars, central, and lateral incisors. Anesthesia was considered successful when two consecutive 80 readings were obtained within 15 min and the 80 reading was continuously sustained for 60 min. Using the articaine solution, successful pulpal anesthesia ranged from 4 to 54% from the central incisor to the second molar. Using the lidocaine solution, successful pulpal anesthesia ranged from 2 to 48%. There was no significant difference (p > 0.05) between the articaine and lidocaine solutions. We concluded that 4% articaine with 1:100,000 epinephrine was similar to 2% lidocaine with 1:100,000 epinephrine in inferior alveolar nerve blocks.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 33 条
[1]  
Certosimo AJ, 1996, OPER DENT, V21, P25
[2]   ENDODONTIC ANESTHESIA IN MANDIBULAR MOLARS - A CLINICAL-STUDY [J].
COHEN, HP ;
CHA, BY ;
SPANGBERG, LSW .
JOURNAL OF ENDODONTICS, 1993, 19 (07) :370-373
[3]  
Daublander M, 1997, Anesth Prog, V44, P132
[4]  
Donaldson D, 1987, J Can Dent Assoc, V53, P38
[5]   AN EVALUATION OF AN ELECTRIC PULP TESTER AS A MEASURE OF ANALGESIA IN HUMAN VITAL TEETH [J].
DREVEN, LJ ;
READER, A ;
BECK, FM ;
MEYERS, WJ ;
WEAVER, J .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :233-238
[6]  
Haas D A, 1995, J Can Dent Assoc, V61, P319
[7]  
HAAS DA, 1990, J CAN DENT ASSOC, V37, P230
[8]   AN EXPERIMENTAL BASIS FOR REVISING THE GRAPHIC RATING-SCALE FOR PAIN [J].
HEFT, MW ;
PARKER, SR .
PAIN, 1984, 19 (02) :153-161
[9]  
Isen D A, 2000, Dent Today, V19, P72
[10]  
Jakobs W, 1995, Anesth Prog, V42, P113