Floor heating and cooling combined with displacement ventilation: Possibilities and limitations

被引:97
作者
Causone, Francesco [1 ]
Baldin, Fabio [2 ]
Olesen, Bjarne W. [3 ]
Corgnati, Stefano P. [1 ]
机构
[1] Politecn Torino, Dept Energet, TEBE Res Grp, I-10129 Turin, Italy
[2] Univ Padua, Dept Appl Phys, I-35131 Padua, Italy
[3] Tech Univ Denmark, Dept Civil Engn, ICIEE, DK-2800 Lyngby, Denmark
关键词
Floor heating; Floor cooling; Displacement ventilation; DV; Thermal comfort; Hybrid systems; COOLED-CEILING SYSTEMS; THERMAL COMFORT; ENERGY; PERFORMANCE; ROOMS;
D O I
10.1016/j.enbuild.2010.08.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Design guidelines envisage that floor heating can be used together with displacement ventilation (DV), provided that the supply air is not overly heated before it can reach heat and contaminant sources. If this is not controlled a mixing flow pattern could occur in the room. The use of floor cooling with DV is also considered possible, although draught risk at ankle level and vertical air temperature differences must be controlled carefully, because they could increase. Few studies on these topics were found in the literature. An indoor environmental chamber was set up to obtain measurements aimed at analysing the possibilities and limitations of combining floor heating/cooling with DV. Air temperature profiles, air velocity profiles, surface temperatures and ventilation effectiveness were measured under different environmental conditions that may occur in practice. These values were compared to equivalent temperature measurements obtained using a thermal manikin. The measurements show that floor heating can be used with DV, obtaining high ventilation effectiveness values. A correlation between the floor heating capacity and the air temperature profile in the room was found. Measurements showed that floor cooling does not increase draught risk at ankle level, although it does increase vertical air temperature differences. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2338 / 2352
页数:15
相关论文
共 41 条
[1]  
ABBAS T, 1999, CODE PRACTICE 17 99
[2]  
[Anonymous], 2007, Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings Addressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics
[3]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
[4]  
[Anonymous], 1998, ISO 7726 ERGONOMICS
[5]  
Babiak J., 2007, LOW TEMPERATURE HEAT
[6]  
Baskin E., 2003, PROJECT 4 3 RESIDENT
[7]   Indoor air quality in rooms with cooled ceilings. Mixing ventilation or rather displacement ventilation? [J].
Behne, M .
ENERGY AND BUILDINGS, 1999, 30 (02) :155-166
[8]  
CARPENTER SC, 1998, ASHRAE T, V104, P1321
[9]  
CAUSONE F, 2009, RADIANT SYSTEMS UPON
[10]   Floor Heating with Displacement Ventilation: An Experimental and Numerical Analysis [J].
Causone, Francesco ;
Olesen, Bjarne W. ;
Corgnati, Stefano P. .
HVAC&R RESEARCH, 2010, 16 (02) :139-160