Improvement in accuracy in potential method for detecting EDM spark locations

被引:5
作者
Han, Fuzhu [1 ]
Grangure, Paul [2 ]
Kunieda, Masanori [2 ]
机构
[1] Tsinghua Univ, State Key Lab Tribol, Dept Precis Instruments & Mechanol, Beijing 100084, Peoples R China
[2] Tokyo Univ Agr & Technol, Dept Mech & Syst Engn, Tokyo, Japan
关键词
EDM; discharge location; potential method; discharge noise;
D O I
10.1016/j.jmatprotec.2007.12.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes an improvement in accuracy in potential method for detecting EDM spark locations. It is known that the discharge locations can be detected by dividing the feeding wire into two braches and measuring the potential difference between the connecting points and the branching points, which appears at the beginning of the discharge. However, because of the noise of the discharge, good sensitivity for detecting discharge locations is difficult to obtain. In this study, we proposed a method in which the potential difference is measured at the end of the discharge to avoid the influence of the discharge noise. The experimental results showed that a better sensitivity and resolution can be obtained when using the voltage peak value which appears at the end of discharge, compared with the method which uses the difference which appears at the beginning of discharge. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 8 条
[1]  
KOJIMA H, 1992, INT S EL ISEM 10, P144
[2]  
KUNIEDA M, 1990, ANN CIRP, V39, P171
[3]  
Kunieda M., 1998, Int. J. Electr. Mach, V3, P53
[4]  
KUNIEDA M, 1992, J JAP SOC PRECISION, V58, P73
[5]  
MUTO K, 1989, INT S EL ISEM 9, P301
[6]  
OBARA H, 1992, INT S EL ISEM 10, P404
[7]  
OBARA H, 2001, INT S EL ISEM 13, P677
[8]  
YDRESKOG L, 1989, INT S EL ISEM 9, P297