Seismic performance of bolted double-web T-stub connections with T-shaped steel column

被引:9
|
作者
Liu, Xue-Chun [1 ]
Zhu, Ya-Nan [1 ]
Chen, Xuesen [1 ]
Li, Yong-Mei [1 ]
机构
[1] Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Bolted connection; Beam-to-column joint; Double-web T -stub; Cyclic tests; Seismic performance; END-PLATE; DESIGN; STIFFNESS; BEHAVIOR; DAMAGE; AISC;
D O I
10.1016/j.jcsr.2022.107168
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bolted connections are convenient for construction, but traditional bolted end-plate joints require gaps for construction, which may cause construction difficulties and installation stress. Bolted T-stub joints could avoid the installation stress, but use more bolts. Improving the traditional bolted T-stub joints, a bolted beam-tocolumn joint configuration using double-web T-stubs and pallets, with less bolts required, was proposed. Cyclic tests and finite element analysis were conducted to analyze the effect of stiffeners, the column web thickness, the end plate thickness of T-stubs and L-stubs, and the beam flange bolt quantity on the performances of the novel joint, e. g. the deformation characteristics, the hysteresis curve, the skeleton curve, the slipping resistance, the yield resistance, the ultimate resistance, the ductility and the rotational capacity. According to the results, the joint could be designed as rigid under small earthquakes or wind loads, and may dissipate the energy mainly through slipping under moderate and large earthquakes to reduce the plastic deformation demand of the beams. Stiffeners of the double-web T-stubs and pallets can increase the joint stiffness and energy dissipation capacity, and more bolts on the beam flanges can increase the joint energy dissipation capacity and resistance. Formulas to calculate the slipping resistance, the yield resistance and the ultimate resistance are derived, providing results are in good agreements with the experimental and finite element results.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Bolted steel connections: Tests on T-stub components
    Swanson, JA
    Leon, RT
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (01): : 50 - 56
  • [2] Seismic performance of bolted T-stub Beam-to-Box column connection
    Derakhshan, H.
    Shekastehband, B.
    STRUCTURES, 2023, 56
  • [3] Behavior of T-stub steel connections bolted to rigid bases
    Bezerra, Luciano M.
    Bonilla, Jorge
    Freitas, Cleirton S.
    Massicotte, Bruno
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 192
  • [4] Experimental Behavior and Modelling of Steel Bolted T-Stub Connections
    Liu, Xiao
    Hao, Zhiming
    Luo, Xin
    Jin, Zhengbao
    BUILDINGS, 2023, 13 (03)
  • [5] A Novel Approach for Bolted T-Stub Connections
    Merve Sağıroğlu
    Mahyar Maali
    Mahmut Kılıç
    Abdulkadir Cüneyt Aydın
    International Journal of Steel Structures, 2018, 18 : 891 - 909
  • [6] A Novel Approach for Bolted T-Stub Connections
    Sagiroglu, Merve
    Maali, Mahyar
    Kilic, Mahmut
    Aydin, Abdulkadir Cuneyt
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2018, 18 (03) : 891 - 909
  • [7] Cyclic modeling of T-stub bolted connections
    Leon, RT
    Swanson, JA
    BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 703 - 710
  • [8] Investigation on tensile performance of T-stub connections bolted by T-bolts
    Sun, Lele
    Liu, Le
    Zhang, Jin
    Wang, Peijun
    Hou, Gangling
    He, Min
    STEEL AND COMPOSITE STRUCTURES, 2025, 54 (06): : 463 - 481
  • [9] Disproportionate collapse performance of partially restrained steel frames with bolted T-stub connections
    Xu, Guoqing
    Ellingwood, Bruce R.
    ENGINEERING STRUCTURES, 2011, 33 (01) : 32 - 43
  • [10] Post Tensioned Tendons for Seismic Retrofitting of Weak Bolted T-stub Connections
    Saberi, Vahid
    Gerami, Mohsen
    Kheyroddin, Ali
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2017, 17 (03) : 877 - 891