Applying water cooled air conditioners in residential buildings in Hong Kong

被引:36
作者
Chen, Hua [1 ]
Lee, W. L. [1 ]
Ylk, F. W. H. [1 ]
机构
[1] Hong Kong Polytech Univ, Bldg Serv Engn Dept, Hong Kong, Hong Kong, Peoples R China
关键词
domestic air conditioners; experimental study; residential buildings; potential energy saving;
D O I
10.1016/j.enconman.2007.12.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this study is to conduct a realistic prediction of the potential energy saving for using water cooled air conditioners in residential buildings in Hong Kong. A split type air conditioner with air cooled (AAC) and water cooled (WAC) options was set up for experimental study at different indoor and outdoor conditions. The cooling output, power consumption and coefficient of performance (COP) of the two options were measured and calculated for comparison. The experimental results showed that the COP of the WAC is, on average, 17.4% higher than that of the AAC. The results were used to validate the mathematical models formulated for predicting the performance of WACs and AACs at different operating conditions and load characteristics. While the development of the mathematical models for WACs was reported in an earlier paper, this paper focuses oil the experimental works for the AAC. The mathematical models were further used to predict the potential energy saving for application of WACs in residential buildings in Hong Kong. The predictions were based on actual building developments and realistic operating characteristics. The overall energy savings were estimated to be around 8.7% of the total electricity consumption for residential buildings in Hong Kong. Wider use of WACs in subtropical cities is, therefore, recommended. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1416 / 1423
页数:8
相关论文
共 26 条
[1]  
Alexander D.K., 1997, HTB2 USER MANUAL VER
[2]   Flow and temperatures outside a high-rise residential building due to heat rejection by its air-conditioners [J].
Bojic, M ;
Lee, M ;
Yik, F .
ENERGY AND BUILDINGS, 2001, 33 (07) :737-751
[3]  
*CENS STAT DEP, 2005, HONG KONG EN STAT AN
[4]  
*CENS STAT DEP, 2007, HONG KONG EN STAT ST
[5]   Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance [J].
Chow, TT ;
Lin, Z ;
Liu, JP .
ENERGY AND BUILDINGS, 2002, 34 (03) :237-244
[6]  
*CLP POW HONG KONG, 2000, DSM HDB
[7]  
*DAIK, PROD CAT RES AIR CON
[8]  
Electric and Mechanical Services Department of the Government of the Hong Kong Special Administrative Region, 2007, HONG KONG EN END US
[9]  
Electrical and Mechanical Services Department, 1995, HONG KONG EN EFF LAB
[10]  
*HONG KONG HOUS AU, FOR PUBL HOUS PROD H